My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Description: Warehouse Remodel Bldg. 1 Date: Tuesday, January 6, 2026 <br /> <br />11 | Page <br /> <br />FIRE PUMPS: <br />When provided, fire pumps shall be located in rooms that are separated from all other areas by 2- <br />hour fire barrier construction. (913.2.1) <br /> <br />PORTABLE FIRE EXTINGUISHERS: <br />Portable fire extinguishers are required. (906.1) <br />See Section 906.1 and Table 906.1 for location requirements. <br />See Section 906.3 for size and distribution requirements. <br /> <br />STANDPIPE AND HOSE SYSTEMS: <br />A standpipe system is not required. (905) <br /> <br />SMOKE AND HEAT REMOVAL: <br />Areas containing high piled combustible storage require smoke and heat removal when required <br />by Table 3206.2 of the IFC. Design to comply with Section 910.3. <br />ACCESSIBLE FACILITIES: <br />Accessible water fountains shall comply with ICC/ANSI A117.1, see Section 602. <br />Toilet facilities shall comply with ICC/ANSI A117.1, see Sections 603 through 609. <br /> <br />ADDITIONAL TOILET REQUIREMENTS: <br />Customers, patrons and visitors shall be provided with public toilet facilities in spaces intended <br />for public utilization. (2902.3) <br />The route to the public facilities shall not pass through kitchens, storage rooms or closets. <br />(2902.3.1) <br />The path of travel to facilities shall not exceed a distance of 500 feet. (2902.3.2) <br />Directional signage indicating route to public facilities shall be posted. Such signage shall be <br />located in a corridor or aisle at the entrance to the facilities. (2902.4.1) <br />Where a toilet is provided for use of multiple occupants, the egress door for the room shall not be <br />lockable from the inside. (2902.3.5) <br />Where a building or tenant space requires a separate toilet facility for each sex and each toilet <br />facility is required to have only one water closet, <br />two family/assisted-use toilet facilities shall be permitted to serve as required separate facilities. <br />Toilet facilities shall not be required to <br />be identified for exclusive use by either sex. (2902.2.1) <br /> <br />LIGHT AND VENTILATION: <br />1. Every space intended for human occupancy shall be provided with natural light by means of <br />exterior glazed openings or shall be provided with artificial light. (1204.1) <br />2. Buildings shall be provided with natural ventilation or mechanical ventilation per the <br />International Mechanical Code. (1202.1) <br />3. Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically <br />ventilated. (1202.5.2.1) <br /> <br />GLAZING REQUIREMENTS: <br />All glazing in hazardous locations is required to be of safety glazing material. (2406.1)
The URL can be used to link to this page
Your browser does not support the video tag.