My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Description: Warehouse Remodel Bldg. 2 Date: Monday, June 9, 2025 <br /> <br />7 | Page <br /> <br />Parapet or roof/ceiling protection required (705.11, Exception 4) <br />Fire protection is not required at the bottom flange of lintels, shelf angles and plates, spanning <br />not more than 6 feet 4 inches if they are part of the structural frame and regardless of the span if <br />they are not part of the structural frame. (704.11) <br />Projections extending beyond the exterior wall can extend 24 inches plus 8 inches for every foot <br />of FSD beyond 3 feet or fraction thereof. (Table 705.2) <br /> Maximum unprotected openings = 15% of wall area. Maximum protected openings = 45% of <br />wall area. (Table 705.8) <br />If there are projections beyond the exterior wall, they shall be of noncombustible materials. <br />(705.2.1) See Section 705.2.3.1 for balconies. <br /> <br />South Side: <br />Group S1 - Bearing walls = 1-hr Nonbearing walls = 0-hr rating on the inside. (705.5, Tables <br />601 & 602) <br />Parapet or roof/ceiling protection required (705.11, Exception 4) <br />Fire protection is not required at the bottom flange of lintels, shelf angles and plates, spanning <br />not more than 6 feet 4 inches if they are part of the structural frame and regardless of the span if <br />they are not part of the structural frame. (704.11) <br />Projections extending beyond the exterior wall cannot extend closer to than 20 feet to the fire <br />separation distance line. (Table 705.2) <br /> No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) <br />If there are projections beyond the exterior wall, they shall be of noncombustible materials. <br />(705.2.1) See Section 705.2.3.1 for balconies. <br /> <br />West Side: <br />Group S1 - Bearing walls = 1-hr Nonbearing walls = 0-hr rating on the inside. (705.5, Tables <br />601 & 602) <br />Parapet or roof/ceiling protection required (705.11, Exception 4) <br />Fire protection is not required at the bottom flange of lintels, shelf angles and plates, spanning <br />not more than 6 feet 4 inches if they are part of the structural frame and regardless of the span if <br />they are not part of the structural frame. (704.11) <br />Projections extending beyond the exterior wall cannot extend closer to than 20 feet to the fire <br />separation distance line. (Table 705.2) <br /> No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) <br />If there are projections beyond the exterior wall, they shall be of noncombustible materials. <br />(705.2.1) See Section 705.2.3.1 for balconies. <br /> <br />Parapet walls must extend 30 inches above the roofing. <br />The parapet wall is required to have the same fire rating as the wall and shall have <br />noncombustible faces for the uppermost 18 inches. (705.11) <br />If roof/ceiling protection is used instead of a parapet wall: <br />4.1 Where roof/ceiling framing are parallel to the wall, framing and support shall be not less than <br />1-hour fire-resistive for a minimum width of 10 feet from the inside of the exterior wall. <br />4.2 Where roof/ceiling framing are not parallel to the wall, the entire span of framing and support <br />shall be not less than 1-hour fire-resistive. <br />4.3 Openings in the roof shall not be located within 10 feet of the exterior wall.
The URL can be used to link to this page
Your browser does not support the video tag.