My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Description: Warehouse Remodel Bldg. 2 Date: Monday, June 9, 2025 <br /> <br />10 | Page <br /> <br />3. Scuppers shall not have an opening dimension of less than 4 inches. (1502.3 <br />4. See sections 1106 and 1108 of the Plumbing code for design requirements. <br /> <br /> <br />AUTOMATIC SPRINKLER SYSTEMS: <br />If openings are not provided in each 50 feet on at least one exterior wall or there is floor area <br />more than 75 feet from an exterior opening, an automatic sprinkler system is required. Openings <br />shall have a minimum dimension of 30 inches. There must be at least 20 sq. ft. of opening in <br />every 50 lineal feet of wall or fraction thereof. The height of the bottom of the opening shall not <br />exceed 44 inches measured from the floor. (903.2.11.1) <br /> <br />An automatic sprinkler system is required where a fire area containing Group S-1 exceeds <br />12,000 square feet (903.2.9 #1, #1) or the combined fire area on all floors exceeds 24,000 square <br />feet. (903.2.9 #1, #3) <br />Note: The size of the fire area may be reduced using fire barriers. See section 707.3.10 for <br />requirements. <br />The fire-resistive rating for the fire barrier assembly is 3 hours. (Table 707.3.10) <br />An automatic sprinkler system shall be provided when the area exceeds 2,500 square feet and is <br />used for the storage of upholstered furniture or mattresses. (903.2.9 #5) <br />Note: The size of the fire area may be reduced using fire barriers. See section 707.3.10 for <br />requirements. <br />The fire-resistive rating for the fire barrier assembly is 3 hours. (Table 707.3.10) <br /> <br />[F] 903.2.10 Group S-2 enclosed parking garages. <br />An automatic sprinkler system shall be provided throughout buildings classified as enclosed <br />parking garages in accordance with Section 406.6 where either of the following conditions <br />exists: <br />1. 1.Where the fire area of the enclosed parking garage exceeds 12,000 square feet (1115 <br />m2). <br />2. 2.Where the enclosed parking garage is located beneath other groups. <br />Exception: Enclosed parking garages located beneath Group R-3 occupancies. <br /> <br />[F] 903.2.10.1 Commercial parking garages. <br />An automatic sprinkler system shall be provided throughout buildings used for storage of <br />commercial motor vehicles where the fire area exceeds 5,000 square feet (464 m2). <br /> <br />Note Limitations <br /> <br />903.2.9.3 Group S-1 upholstered furniture and <br />mattresses. <br />An automatic sprinkler system shall be provided throughout a Group S-1 fire area used <br />for the storage of upholstered furniture or mattresses that exceeds 2,500 square feet <br />(232 m2). <br />Exception: Self-service storage facilities (mini-storage) no greater than one story above <br />grade plane where all storage spaces can be accessed directly from the exterior.
The URL can be used to link to this page
Your browser does not support the video tag.