My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14047 Azurite St NW Buildings 2 and 2 December 22, 2025 <br /> <br />14 | Page <br /> <br />Manually operated flush bolts and surface bolts are not permitted. (1010.1.9.5) <br />Exception 3: Where a pair of doors serves an occupant load of less than 50, manually operated <br />edge- or surface-mounted bolts are permitted on the inactive leaf. The inactive leaf shall contain <br />no doorknobs, panic bars or similar operating hardware. <br />Exception 2: Where a pair of doors serves a storage or equipment room, manually operated edge- <br />or surface-mounted bolts are permitted on the inactive leaf. <br />The unlatching of any door or leaf shall not require more than one operation. (1010.1.9.6) <br />Exception 2: Where manually operated bolt locks are permitted. <br />Exception 3: Doors with automatic flush bolts as permitted. <br /> <br />LOCKS AND LATCHES: <br />Egress doors shall be readily openable from the egress side without the use of a key or any <br />special knowledge or effort. (1010.1.9) <br />Locks and latches shall be permitted to prevent operation where any of the following exists: <br />(1010.1.9.4) <br />2. The main door or doors in Group B, F, M and S areas are permitted to be equipped with key <br />operating locking devices from the egress side provided: <br />2.1 The locking device is readily distinguishable as locked. <br />2.2 A readily visible durable sign is posted on the egress <br />side stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED <br />3. Where egress doors are used in pairs, automatic flush bolts shall be permitted to be used, <br />provided the door leaf having the automatic flush bolts has no doorknob or surface-mounted <br />hardware. <br />5. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism. <br /> <br /> <br /> <br />MINIMUM NUMBER OF PLUMBING FIXTURES: (2902.1) <br /> <br /> NUMBER WATER CLOSETS LAVATORIES DRINKING <br />FL NAME OF AREA OCC MALE FEMALE MALE FEMALE FOUNTAINS <br />--------------------------------------------------------------------- <br />F1 Building 2 16 1 1 1 1 1 <br />TOTAL for 1st FLOOR 16 1 1 1 1 1 <br /> <br />NOTES ON THE TOTAL NUMBER OF PLUMBING FIXTURES: <br />The number of fixtures for a floor may not match total number of fixtures per area. <br />1. Fixtures for accessory areas are not included in the floor total. <br />2. The number of fixtures for each area are rounded up to the next whole number. Floor totals are <br />not rounded up until the floor total is obtained. <br />If the fixtures only serve an area, use number shown for each area. <br />If the fixtures serve an entire floor, use number shown for totals. <br /> <br /> <br />ACCESSIBLE FACILITIES: <br />Accessible water fountains shall comply with ICC/ANSI A117.1, see Section 602. <br />Toilet facilities shall comply with ICC/ANSI A117.1, see Sections 603 through 609.
The URL can be used to link to this page
Your browser does not support the video tag.