My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14047 Azurite St NW Buildings 2 and 2 December 22, 2025 <br /> <br />16 | Page <br /> <br /> <br />East Side: <br />Group S1 - This wall must meet fire wall requirements. (706) rating on both sides. (705.5, <br />Tables 601 & 602) <br /> <br />Fire protection is not required at the bottom flange of lintels, shelf angles and plates, spanning <br />not more than 6 feet 4 inches if they are part of the structural frame and regardless of the span if <br />they are not part of the structural frame. (704.11) <br />Projections extending beyond the exterior wall are not permitted. (Table 705.2) <br />Combustible projections extending within 5 feet of the line used to determine the fire separation <br />distance or located where openings are not permitted or where protection of openings are <br />required shall be of at least 1-hour fire-resistive-rated construction, Type IV or fire-retardant- <br />treated wood. (705.2.3) <br /> <br />South Side: <br />Group S1 - Bearing walls = 0-hr Nonbearing walls = 0-hr rating on the inside. (705.5, Tables <br />601 & 602) <br /> <br />Projections extending beyond the exterior wall cannot extend closer to than 20 feet to the fire <br />separation distance line. (Table 705.2) <br /> No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) <br />Combustible projections extending within 5 feet of the line used to determine the fire separation <br />distance or located where openings are not permitted or where protection of openings are <br />required shall be of at least 1-hour fire-resistive-rated construction, Type IV or fire-retardant- <br />treated wood. (705.2.3) <br /> <br />West Side: <br />Group S1 - Bearing walls = 0-hr Nonbearing walls = 0-hr rating on the inside. (705.5, Tables <br />601 & 602) <br /> <br />Projections extending beyond the exterior wall cannot extend closer to than 20 feet to the fire <br />separation distance line. (Table 705.2) <br /> No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) <br />Combustible projections extending within 5 feet of the line used to determine the fire separation <br />distance or located where openings are not permitted or where protection of openings are <br />required shall be of at least 1-hour fire-resistive-rated construction, Type IV or fire-retardant- <br />treated wood. (705.2.3) <br /> <br />FIRE-RESISTANCE RATING REQUIREMENTS:(Table 601 except as noted) <br />Exterior walls . Minimum fire resistance rating = FIRE-RESISTANCE RATING FOR <br />EXTERIOR WALLS above <br />Primary structural frame may be of any material. Minimum fire resistance rating = 0 hour <br />Interior bearing wall may be of any material. Minimum fire resistance rating = 0 hour <br />Interior nonbearing wall may be of any material. Minimum fire resistance rating = 0 hour <br />Floor/ceiling assembly may be of any material. Minimum fire resistance rating = 0 hour
The URL can be used to link to this page
Your browser does not support the video tag.