BUILDER/CONTRACTOR RESPONSIBILITIES <br />Sutler Mfg. follows the guidelines as outlined in the AISC and M3MA Codes of Standard Practice. <br />Sutler Mfg. standard product specifications, design, fabrication, quality criteria shall govern all work <br />unless stipulated otherwise in the contract documents. In case of discrepancies between <br />Sutler Mfg. structural plans and plans for other trades, Butler Mfg. structural plans shall govern. <br />It is the responsibility of the 3uilder to obtain approvals and permits from all governing agencies <br />and jurisdictions as required. Approval of 3utler vlfg drawings constitutes the builders acceptance <br />of 3utler interpretation of the contract purchase order. Unless specific design criteria concerning <br />interface design and details are furnished as part of the contract, 3utler Mfg. design assumptions <br />shall govern. <br />Butler engineers are not Project Engineers or Engineer of Record for the overall project. Butler <br />engineering supply sealed engineering design data and drawings for Butler supplied material as part <br />of the overall project for use by others to obtain permits, approvals, and coordinate with other <br />trades. All interface and/or compatibility of any materials not furnished by 3utler are to be <br />considered and coordinated by the builder or A/E firm. <br />CONSTRUCTION & ERECTION RESPONSIBILITY <br />The Builder is responsible for construction in strict accordance with 3utler Vfg. <br />"FOR CONSTRUCTION" drawings and all applicable product installation guides. Butler is not <br />responsible for work done from any other 3utler drawings that are not marked <br />"FOR CONSTRUCTION", nor any drawings prepared by others. <br />As erected field assemblies of members shall be as specified in M3MA Code of Standard Practice <br />(in Canada — CSA S16), which require L/500 tolerance of installed members. Occasional <br />field work including shimming, cutting, coping, and drilling for final fit —up are considered part of <br />erection. Specified field work and field welding conditions indicated on these drawings shall <br />also be included in the erectors scope of work. See Erection Guide for shimming procedure. <br />For building with top riding bridge cranes see Crane Data drawing for column plumb tolerance. <br />The building erector shall be properly licensed and experienced in erecting metal building systems. <br />The Builder is responsible for having knowledge of, and shall comply with, all OSHA requirements <br />and all other governing site safety criteria. The builder is responsible for designing, supplying, <br />locating and installing temporary supports and bracing during erection of the building. 3utler <br />bracing is designed for code required loads after building completion and shall not be considered <br />as adequate erection bracing. See Erection Guide. <br />Shimming of steel buildings during erection may be required to accomodate allowable tolerances <br />during fabrication and erection. Special care should be taken by the building erector to shim <br />connections where key dimensions must be maintained for building performance as even small <br />tolerances can have a significant impact on critical dimensions such as height, clearances and <br />plumbness, especially as the size of the member or building increases. Conditions where shimming <br />should be expected can include but are not limited to large door openings, critical clear height <br />requirements, cranes, buildings greater than 45 feet in height, clear spans greater than 125 feet <br />and adjacent frames with different characteristics (like clear span frames adjacent to an endwall <br />or modular frame). Shims are normally provided by the erector, but may be ordered upon request <br />by contacting your Project vanager. <br />EXISTING STRUCTURES <br />Butler must be advised of any structure that is within 20 ft. of Sutler's building. Load effects <br />from snow drifting, wind effects, and seismic separation must be considered for both the new and <br />existing structures. 3utler has designed the new 3utler building for these effects. The owner/builder <br />are responsible for employing a Professional Engineer to review and verify the existing structure <br />for all load effects from the adjacent 3utler building. <br />BRACING <br />Tension brace rods work in pairs to balance forces caused by initial tensioning. Care must be <br />taken while tightening brace rods so as not to cause accidental or misalignment of components. <br />All rods must be installed loose and then tightened. Rods should not exhibit excessive sag. For <br />long or heavy rods, or angles it may be necessary to support the rods at mid —bay by suspending <br />them from secondary members. <br />3racing for seismic or wind loading of objects or equipment that are not a part of the 3utler <br />structure must be designed by a qualified professional to deliver lateral loads to primary frames <br />and rod bracing struts. Equipment bracing and suspension connections must not impose torsion <br />or minor axis loads, or cause local distortion in any 3utler components. Butler accepts no <br />responsibility for design or installation of bracing systems not furnished by 3utler. <br />FIELD WELDING <br />All field welding shall be done at the direction of a design professional, and done in accordance <br />with governing requirements (AWS in USA, CWB in Canada) by welders qualified to perform the <br />welding as directed by the applicable welding procedure specification (WPS). A WPS shall be <br />prepared by the contractor for each welding variation specified. The contractor is responsible for <br />any special welding inspection as required by local jurisdiction. Filler metal shall be <br />70 ksi (480 MPa) tensile strength. For welds in high seismic force resisting system <br />Seismic Cat D. E or F). minimum Charpy V—Notch toughness shal meet AISC-341 criteria <br />20 ft—Ibs min @ ODeg F). Interpass temperatures shall not exce'dr FEOWI c* R'S SEAL APPLIES <br />ONLY TO THE WORK PRODUCT OF BUTLER <br />MFG. AND DESIGN AND PERFORMANCE <br />REQUIREMENTS SPECIFIED BY BUTLER. <br />THE BUTLER MFG. ENGINEER'S SEAL DOES <br />NOT APPLY TO THE PERFORMANCE OR <br />DESIGN OF ANY OTHER PRODUCT OR <br />COMPONENT FURNISHED BY BUTLER EXCEPT <br />TO ANY DESIGN OR PERFORMANCE <br />REQUIREMENTS SPECIFIED BY BUTLER. <br />SIGNAGE <br />The Builder is responsible for furnishing signs as required by Code and the Building Department, <br />including but not limited to, exits, occupancy limits, floor loading limits, and bulk storage limits. <br />Floor loading signs shall clearly indicate maximum floor live load permitted. <br />Sulk storage facilities shall have signs clearly posted on all loaded walls indicating the type <br />of commodity stored and the maximum storage height. Signs shall be clearly visible when <br />building is fully loaded to design level. Overloading of floors or walls may result in failure. <br />DELIVERIES <br />It is the responsibility of the builder to have adequate equipment available at the job site to <br />unload trucks in a safe and timely manner. The Builder will be responsible for all retention <br />charges from carriers as a result of job site unloading delays. <br />Claims for damage or shorts MUST be noted on the Bill —of —Lading or delivery <br />receipt and filed against the carrier by the consignee as per Butler's Terms of Sales (F.0.3. Plant) <br />under the Uniform Commercial Code. It is critical that damages or shorts be noted on the <br />Bill —of —Lading or you have little recourse with the carrier. Immediately upon delivery of material, <br />material quantities are verified by the Builder against quantities billed on the shipping document. <br />Neither the Manufacturer nor the carrier is responsible for material shortages against quantities <br />billed on the shipping document if such shortages are not noted on the shipping documents upon <br />delivery of material and acknowledged by the carriers agent. For materials concealed in bundles, <br />boxes, or crates, shortages must be reported immediately upon unpacking. Should products get <br />wet, bundled and crated materials must be unpacked and unbundled immediately to provide <br />drainage of trapped moisture. See Erection Guide for proper job site storage procedure. <br />SEALANTS <br />Sealants shall be applied in strict accordance with Butler details or weather tightness will be <br />compromised. Sealant must be applied in temperatures and weather conditions <br />consistent with labeling. <br />INDEPENDENT MEZZANINES <br />Independent mezzanines must be designed by a professional engineer. The engineer must ensure <br />that proper isolation from the 3utler building has been provided to avoid structural damage due to <br />differential movements, or inadvertently apply loads to the 3utler structure. Butler accepts no <br />responsibility for the design of the independent mezzanine. <br />FIRE CODE COMPLIANCE <br />It is the responsibility of the project design professional and builder to comply with local fire code <br />regulations including consideration of, but not limited to, building use and occupancy, all building <br />construction materials, separation requirements, egress requirements, fire protection systems, etc. <br />Builder shall advise Butler of any special requirements to be furnished by 3utler. <br />FIELD MODIFICATIONS <br />Modifications to this building from details and instructions contained on these drawings must be <br />approved in writing by 3utler Mfg. engineers, or other licensed structural engineer. This includes, <br />but is not limited to, removal of roof or wall cladding, removing or moving any flange braces or <br />rod braces, cutting of openings for doors, windows or RTU's, correction of fabrication errors, etc. <br />The owner shall not impose loads to this structure beyond what is specified for this building in <br />the contract documents. Butler Vfg. accepts no responsibility for the consequences of any <br />unauthorized additions, alterations, or added loads to this structure. <br />If the builder intends to invoice Butler Mfg. for modifications in excess of $1000, The builder <br />must notify Butler Mfg. immediately, and obtain a Work Authorization from Butler Mfg prior to <br />proceeding. All final claims must be submitted to Butler vlfg with all supporting documentation <br />within 30 days of the building completion. Claims submitted without work authorizations, or after <br />30 days will not be accepted. Correction of minor misfits, shimming and plumbing, moderate <br />amount of reaming, drilling, chipping / cutting and minor welding are considered by Code of <br />Standard Practice to be part of erection are not subject to claim reimbursement. <br />CONCRETE/MASONRY/CONVENTIONAL STUD WALLS <br />The engineer responsible for the design of the wall system is responsible for coordinating with, or <br />specifying to Butler Mfg, any wall to steel compatibility issues such as drift and deflection <br />compatibility, special base details, and wall to 3utler steel connections. All fasteners, sealant and <br />counter flashing of wall systems are to be provided by contractor. The engineer responsible for <br />the wall shall design the anchorage to Butler supporting elements consistent with Code <br />required forces. <br />THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF <br />BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE <br />APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT <br />SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT <br />PRIOR WRITTEN APPROVAL OF BUTLER MFG. <br />THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE <br />GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS <br />DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. <br />ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, <br />INCLUDING THE CORRECT USE OF TEMPORARY BRACING. <br />D <br />PANELS <br />Oil canning is an inherent characteristic of cold formed steel panels. It is the result of several <br />factors that include induced stresses in the raw material delivered to Sutler, fabrication methods, <br />installation procedures, and post installation thermal forces. Thru fastened panels will exhibit <br />some dimpling when installed, especially when insulation is installed between panels and <br />secondary supports. Dimpling can be minimized by careful installation, taking care not to <br />over drive fasteners. <br />Roof rumble is a phenomenon that is caused by wind gusts lifting up on the roof panels and then <br />springing back into place. All panels experience this action to some degree, especially with <br />concealed clip Standing Seam panels. Roof rumble noise may be minimized by providing a layer <br />of blanket insulation between the panels and any hard support surface such as steel secondary <br />members, substrates such as plywood, steel decking, or rigid board insulation. A minimum of <br />3 inch thick blanket is recommended over steel secondary members, or 2 inch over substrates. <br />Oil canning, dimpling, and roof rumble do not affect the structural integrity or weather tightness <br />of the panels and is not grounds for rejection of panels. <br />The Standing Seam joint detail is designed with an interlocking feature for ease of installation. <br />However, it is imperative that installed Standing Seam panels be secured to the secondary <br />structural members and properly seamed prior to departure from the job site each day. <br />SKYLIGHTS <br />Local building departments may require added fall restraint due to conditions that may affect the <br />skylight structural integrity. It is the responsibility of the builder to determine and provide any <br />added fall restraint under the skylight as may be required by your building department. <br />RAIN WATER RUNOFF <br />Drainage systems must be designed by the project professional to comply with code requirements. <br />3utler is not responsible for drainage designs, overflow scuppers, down piping, etc. The project <br />professional and contractor are responsible to ensure that primary drains and overflow devices <br />such as scuppers and auxiliary drains are provided as required for the required rain intensity at <br />the building perimeter and at valley conditions to prevent ponding. <br />STEEL SHOP COAT <br />The purpose of Sutler's shop coat is to provide protection for the steel members during <br />transportation, during temporary job site storage and during erection. Standard shop formulation <br />is not designed to perform as a finish coat when exposed to environmental conditions. Members <br />shall be kept free of the ground and properly drained during job site storage. It is the Builder's <br />responsibility to ensure that if a finish coat is being applied over Butler shop coat that the <br />painting contractor verifies compatibility between his finish coat and 3utler's shop coat. <br />BUTLER MFG. ACCREDITATIONS AND APPROVALS <br />Fabricator Approvals <br />IAS AC472 Approvals: (www.iasonline.org/services/metal—building—inspection) <br />Listed under BlueScope 3uildings North America, Inc. <br />City of Los Angeles, CA #F800031; City of Houston, TX 767; <br />City of Phoenix, AZ C19-02008; Clark County, NV 43 & 833, San 3ernardino County, CA 289, <br />State of Utah, City of Richmond, Ca. <br />Design Approvals <br />IAS AC472 Approvals: (www.iasonline.org/services/metal—building—inspection) <br />Listed under Butler Manufacturing, a Division of BlueScope 3uildings North America, Inc. <br />Canadian CSA A660 Certifications <br />(www.cwbgroup.org) <br />Listed under BlueScope 3uildings North America, Inc. <br />Engineering Certifications of Authorization <br />USA--AL#CA-5589—E; AZ#22225-0; AR#576; FL#30427; GA#PEF007551; ID#C-2470; IL#184-002649; <br /><S#E-29; KY#4490; _A#EF6722; MS#E-0592; MO#E-2010007736; NC#F-0998; ND#1579PE; <br />NJ#24GA28318800; NV#20437; OH#05898; OK#CA4170PE; RI#8838; SC#6206; SD#C-1787; TX#F4828; <br />VA#0411001520; VA#0411001518; WA#4119; WV#C03059-00 <br />CAN--A3#P08900; NB#F0951; NL#D0044; NS#30123; NT#P062; ON#100148796; and YT#PP134 <br />BUTLER MANUFACTURING <br />1540 GENESSEE ST. KANSAS CITY, MO 64102 <br />REV: DATE: BY: <br />DRAWING SCALE: <br />NTS <br />DESCRIPTION: <br />ERECTION NOTES <br />BUILDER: ARAA Athletic Facility <br />CUSTOMER: <br />LOCATION: Ramsey, Minnesota <br />PROJECT: Athletic Training Facility <br />BUILDERS PO#: <br />JOB #: <br />DATE: <br />12/6/2024 <br />DRAWN/CHECK: <br />Butler Manufacturing <br />VPC VERSION: ADVNXT 6.8 <br />a division of BlueScope Buildings North America, Inc. <br />PAGE: <br />VPC FILENAME: adv1409203395 <br />12/6/2024 <br />11:32:01 <br />