Laserfiche WebLink
ADDITION <br />FOR WILDLIFE <br />RESEARCH <br />WILDLIFE RESEARCH\ADDITION\WILDLIFE RESEARCH ADDITION—T1 <br />ai <br />E <br />0 <br />a) <br />GENERAL INFORMATION <br />A. PROJECT NAME: Addition For Wildlife Research <br />B. PROJECT LOCATION: Lot 1 Sc 3, Block 1, Sunfish Lake Business <br />Park Third Addition, Romsey, MN <br />C. ZONING AND LAND USE: L1 Light Industrial <br />D. LOT SIZE: 4.74 Acres 206,299 s.f. <br />E. GREEN SPACE COVERAGE: 43,600 s.f./206,299 s.f. = 21.1% > 20% <br />F. BUILDING COVERAGE: 88,150 s.f./206,299 s.f. = 42.7% < 50% <br />CUP REQUIRED FOR TWO PRIMARY BUILDINGS ON ONE LOT <br />APPLICABLE CODES: <br />A. RAMSEY ZONING ORDINANCE <br />B. MINNESOTA STATE BUILDING CODE (MSBC) <br />- INCLUDING - <br />C. CHAPTER 1305 - INT'L BUILDING CODE 2020 <br />D. CHAPTER 1311 - INT'L EXISTING BUILDING CODE 2020 <br />E. CHAPTER 1315 - NATIONAL ELECTRIC CODE 2023 <br />F. CHAPTER 1322/23 - INT'L ENERGY CONSERVATION CODE 2024 <br />G. CHAPTER 1341 - MN ACCESSIBILITY CODE 2020 <br />H. CHAPTER 1346 - INT'L MECHANICAL CODE 2020 <br />I. CHAPTER 4714 - MN PLUMBING CODE 2020 <br />Current Edition <br />Edition <br />Edition <br />Edition <br />Edition <br />Edition <br />Edition <br />Edition <br />BUILDING CLASSIFICATION <br />A. OCCUPANCY GROUPS/ TYPE OF CONST (IBC Chpt 3 & IBC Chpt 6) <br />1. Office - Group B <br />Existing - Type of Construction - II-B <br />Building - Area 4,125 s.f. <br />- Proposed Height 31'-6", 1.5 Stories <br />2. Warehouse Group S-1 <br />Existing - Type of Construction - II-B <br />Building - Existing Area - 35,875 s.f. <br />- Addition Area - 36,000 s.f. <br />- Proposed Height - 31'-6", 1.5 Stories <br />3. Warehouse - Group S-1 <br />Accessory - Type of Construction - II-B <br />Building - Area 13,500 s.f. <br />- Proposed Height 28'-8', 1 Story <br />4. Mixed Occupancy (IBC 508) <br />- Group B is a Non -Separated Use From Group S-1 <br />5. Incidental Uses (IBC 509) <br />- None <br />B. FIRE -RESISTANCE -RATED CONSTRUCTION <br />1. Building Elements (IBC Tables 601 & 602) <br />Element Rating <br />Structural Frame 0 Hours <br />Exterior Bearing Walls 0 Hours <br />Interior Bearing Walls 0 Hours <br />Exterior Non -Bearing Walls 0 Hours <br />Interior Non -Bearing Walls 0 Hours <br />Floor Construction 0 Hours <br />Roof Construction 0 Hours <br />C. <br />2. Exterior Wall Openings (IBC Table 705.8) <br />- Separation Distance 20-25 Feet at North wall <br />Classification Area of Opening <br />Unprotected <br />Protected <br />3. Fire Walls (IBC 706) <br />- Not Required - <br />4. Fire Barriers (IBC 707) <br />Fire Borrier <br />No Limit <br />No Limit <br />Mechanical Room 105 <br />Rating <br />1 Hour <br />Opening <br />45 Minute <br />ROOF AND INTERIOR FINISH REQUIREMENTS <br />1. Minimum Wall And Ceiling Finish Requirement (IBC Table 803.13) <br />Building Component Finish Class <br />Vertical Exits/ <br />Exit Passageways <br />Exit Access Corridors/ <br />Other Exit ways <br />Rooms and Enclosed <br />Spaces <br />2. Minimum Roof Covering Classification (IBC Table 1505.1) = Class C <br />- (Contractor To Provide Class A Roof Assembly) <br />Class B - Group B <br />Class C - Group S-1 <br />Class C <br />Class C <br />AUTOMATIC SPRINKLER REQUIREMENTS <br />A. AN NFPA 13 AUTOMATIC SPRINKLER SYSTEM IS PROVIDED <br />THROUGHOUT THE BUILDING (IBC 903.3.1.1) <br />1. Required Location(s) (IBC 903.2) <br />- Throughout The Building When the Fire Area Containing <br />Group S-1 Exceeds 12,000 s.f., Or Exceeds 3 Stories, Or The <br />Combined Fire Areas Of Group S-1 Exceeds 24,000 s.f. <br />COMMERCIAL CODE CON <br />ALLOWABLE HEIGHT, ALLOWABLE AREA <br />Primory Building <br />(Non -Separated Use - Group S-1 Is More Restrictive Than Group B) <br />A. ALLOWABLE HEIGHT (IBC Table 504.3/504.4) <br />1. Group S-1, Type II-B <br />- Sprinklered 75'-0", 3 Stories <br />2. Height Check <br />- Actual # Stories < 1 Stories <br />- Actuol Bldg Hght < 31'-6" <br />B. ALLOWABLE AREA (IBC Table 506.2) <br />(Non -Separated Use - Group S-1 Is More Restrictive Than Group B) <br />1. Group S-1, Type II-B <br />- Tabular Area = 70,000 s.f. <br />- Frontage Increase (IBC 506.3) <br />ox 0' > 20') \ x (30 > 20') = 7,392 s.f. <br />(78C (1160') -.25 J 30' <br />Per Floor = 77,392 s.f. <br />2. Area Check <br />- Whole Building Areo Check <br />76,000/77,392 = 98.2% < 100% <br />ALLOWABLE HEIGHT, ALLOWABLE AREA <br />Accessory Building <br />(Non -Separated Use - Group S-1 Is More Restrictive Thon Group B) <br />A. ALLOWABLE HEIGHT (IBC Table 504.3/504.4) <br />1. Group S-1, Type II-B <br />- Sprinklered 75'-0", 3 Stories <br />2. Height Check <br />- Actuol # Stories < 1 Stories <br />- Actuol Bldg Hght < 28'-8" <br />B. ALLOWABLE AREA (IBC Table 506.2) <br />(Non -Separated Use - Group S-1 Is More Restrictive Thon Group B) <br />1. Group S-1, Type II-B <br />- Tabular Areo <br />- Frontage Increase (IBC 506.3) <br />x( (330' > 20') <br />(480') <br />70,000 s.f. <br />(30 > 20') = 7,656 s.f. <br />30' <br />Per Floor = 77,656 s.f. <br />2. Area Check <br />- Whole Building Areo Check <br />13,500/77,656 = 17.4% < 100% <br />MEANS OF EGRESS <br />A. DESIGN OCCUPANT LOAD (IBC Chpt 1004) <br />1. Office - 4,125 s.f. @ 1/150 s.f. = 28 Occupants <br />2. Warehouse - 71,875 s.f. @ 1/500 s.f. = 144 Occupants <br />3. Accessory Warehouse - 13,500 s.f. @ 1/500 s.f. = 27 Occupants <br />B. EXIT/ EXIT ACCESS <br />1. Number Required (IBC Table 1006.2.1, 1006.3.2) = 2 <br />2. Number of Accessible Required (IBC 1009) = 2 <br />3. Arrangement (IBC 1007) <br />- Not Less Than 1/3 Overall Diagonal (Sprinklered Building) <br />4. Travel Distance Maximums <br />- Exit Access (IBC 1017) B = 300' <br />- Exit Access (IBC 1017) S-1 = 400' <br />- Common Path of Egress (IBC 1006.2.1) = 100' <br />- Dead Ends (IBC 1020.4) = 50' <br />5. Sizing (The Greater of Two Conflicting Widths Shall Be Used) <br />- Design Egress Sizing (IBC 1005.3) <br />Stairways (Occ Load x .3) <br />Other Components (Occ Load x .2) <br />- Stairways (IBC 1011.2) <br />- Corridors (IBC 1020.2) <br />- Exit Passageways (IBC 1024.2) <br />- Exit Doors (IBC 1010.1.1) <br />= N/A <br />= 34.4" / 5.4" <br />= 44" <br />= 44" <br />= 44" <br />= 32" Min Clear <br />48" Max Nom <br />6. Doors <br />- Swing (IBC 1010.1.2.1) <br />Side Hinged Swinging Out At Occupant Load Of 50 Or More <br />- Landings (IBC 1010.1.6) <br />Width Not Less Than Width of Door Or Stairway <br />Length in Direction of Travel Not Less Than 44" <br />- Thresholds (IBC 1010.1.7) <br />Max Height = 1/2" - 1:2 Beveled Edge If 1/4"-1/2" <br />Door Arrangement (IBC 1010.1.8) 48" + Door Width Apart <br />- Lock or Latch (IBC 1010.1.9) <br />Operable From Egress Side Without Use of Knowledge or Keys. <br />Manually Operated Flush Bolts Permitted on Inactive leaf. <br />- Panic/ Fire Exit Hardware (IBC 1010.1.10) <br />Not Required At Exit/Exit Access Doors <br />Sun* <br />143rd Ave. <br />VICINITY MAP <br />NOT TO SCALE <br />Sunfish Loke Blvd. <br />PLUMBING FIXTURES (PRIMARY BUILDING) <br />A. NUMBER FIXTURES REQUIRED (IBC 2902.1) <br />1. Group B <br />- 28 Occupants <br />- 14 Female Occupants, 14 Male Occupants <br />Required <br />Fixture <br />Water Closets <br />Urinals - <br />Lavatories <br />Bathtubs/ Showers <br />Drinking Fountoins 28 At 1/100 = 0.28 <br />Service Sink 1 <br />Men <br />Women <br />2. Group S-1 (Warehouse) <br />- 144 Occupants <br />PLIANCE <br />14 At 1 /2 5= 0.5614 At 1 /2 5= 0.56 <br />14 At 1/40 = 0.35 14 At 1/40 = 0.35 <br />- 72 Female Occupants, 72 Male Occupants <br />Required <br />Fixture <br />Water Closets <br />Urinals <br />Lavatories <br />Bathtubs/ Showers <br />Drinking Fountoins <br />Service Sink <br />Men <br />Women <br />72 At 1/100=0.72 72 At 1/100=0.72 <br />72 At 1/100=0.72 72 At 1/100=0.72 <br />144 At 1/1000 = 0.14 <br />3. Total Number of Plumbing Fixtures Required <br />Required Provided <br />Men Women Men Women <br />Fixture <br />Water Closets 1.28 1.28 3 2 <br />Urinals - - 2 - <br />Lavatories 1.07 1.07 1 1 <br />Bathtubs/ Showers - - - - <br />Drinking Fountoins 0.42 2 <br />Service Sink 1 1 <br />Unisex <br />1 <br />1 <br />B. LOCATION OF FIXTURES (IBC 2902.3.3) <br />- Not More Than 1 Story Above Or Below Regular Working Area <br />- Travel Distance Less Thon 500 ft <br />C. SIGNAGE (IBC 2902.4) <br />- A Legible Sign For Each Sex Shall Be Provided Near The <br />Entrance To The Toilet Facility <br />PLUMBING FIXTURES (ACCESSORY BUILDING) <br />A. NUMBER FIXTURES REQUIRED (IBC 2902.1) <br />1. Not normally occupied. <br />Required Provided <br />Men Women Men Women Unisex <br />Fixture <br />Water Closets - - - - 1 <br />Urinals - - - - - <br />Lavatories - - - - 1 <br />Bathtubs/ Showers <br />Drinking Fountoins <br />Service Sink - 1 <br />B. LOCATION OF FIXTURES (IBC 2902.3.3) <br />- Not More Than 1 Story Above Or Below Regular Working Area <br />- Travel Distance Less Thon 500 ft <br />C. SIGNAGE (IBC 2902.4) <br />- A Legible Sign For Each Sex Shall Be Provided Near The <br />Entrance To The Toilet Facility <br />NORTH <br />OTHER <br />A. ACCESSIBILITY <br />1. Building is Accessible <br />B. GUARDS (IBC 1015) <br />1. 42" High Minimum Guards Shall Be Installed Where A Change In <br />Levels Drops 30" Or More. <br />C. ROOF ACCESS (IMC 306.5) <br />1. 60' Ships Ladder To 8 s.f. Roof Hatch (Min Dim 1'-8") Provided <br />D. CONCEALED SPACES <br />1. Floors (IBC 718.3) <br />- Draftstops Not Required in Sprinklered Building <br />2. Attics (IBC 718.4) <br />- Draftstops Not Required in Sprinklered Building <br />E. VENTILATION <br />1. Attics (IBC 1202.2) <br />- Not Required <br />2. Under -Floors (IBC 1202.4) <br />- Not Required <br />F. ATTIC ACCESS (IBC 1208.2) <br />1. Not Required <br />G. SAFETY GLAZING (IBC 2406) <br />1. Safety Glazing Shall Be Installed In Hazardous Locations As <br />Specified In IBC 2406.4 <br />H. RECYCLING SPACE (MSBC 1303.1500) <br />1. .0025 x 89,500 s.f. = 224 s.f. Required <br />J. FIRE ALARM AND DETECTION SYSTEMS <br />1. Fire Alarm And Detection System Not Required (IBC 907.2) <br />2. If Required Provide Audible And Visible Alarm Notification Devices <br />(IBC 907.5, NFPA 72) <br />K. SMOKE AND HEAT VENTS (IBC 910) <br />1. Required For Group F-1 or S-1 Occupancies With 50,000 s.f. <br />of Undivided Area Unless an ESFR Sprinkler System Is Provided <br />L. PARKING AND MANEUVERING (Ramsey Zoning Ordinance) <br />1. Parking Stall Calculation (Practical Calculation) <br />CURRENT EMPLOYEES <br />FUTURE EMPLOYEES <br />VISITORS <br />Total Stalls Required <br />Total Stalls Provided <br />Accessible Requirement Per 50 Stalls <br />(IBC Table 1106.1) <br />20 Stalls <br />5 Stalls <br />5 Stalls <br />30 Stalls <br />46 Stalls <br />ANSI/ASHRAE STANDARD 90.1-2019 <br />Note: Compliance Is For Building Envelope Only. The Design -Build <br />HVAC and Electrical Designers Must Submit Documentation Proving <br />Compliance With HVAC, Lighting, And Water Heating <br />GENERAL <br />A. Space Conditioning Category (5.1.2) <br />1. Nonresidential Conditioned Space <br />B. Climate (5.1.4) <br />1. Zone 6 - Southern Minnesota <br />COM <br />A. PrescriptivePLIANCE Building Envelope Option (5.2) <br />MANDATORY PROVISIONS <br />A. Components Of The Building Envelope Shall Comply With Section 5.4 <br />1. Insulation (5.4.1) Shall Comply With Section 5.8.1 <br />2. Fenestration/ Door Performance (5.4.2) Shall Comply With Section 5.8.2 <br />3. Air Leakage (5.4.3) <br />The Building Envelope Shall Contain An Air Barrier And Be <br />Sealed At The Following Areas: <br />- Joints Around Fenestration And Door Frames <br />- Junctions Between Walls and Floors, Walls At Building <br />Corners, Walls and Roofs or Ceilings <br />- Penetrations Of Utility Services At Walls, Floors, and Roofs <br />- Building Assemblies Used As Ducts Or Plenums <br />- Joints, Seams, Conn. Between Planes Or Changes In Air <br />Barrier Materials <br />Fenestration and Doors - According To 5.4.2 <br />Loading Dock Weatherseals - Required According To 5.4.3.2 <br />Vestibules - Required at Building Entrances According To 5.4.3.3 <br />PRESCRIPTIVE REQUIREMENTS <br />Table 5.5-6 <br />Building Component <br />Maximum <br />Assembly <br />Minimum <br />Insulation <br />ROOF: Entirely Above Deck U-0.032 R-30 (ci) <br />WALLS: Mass U-0.080 R-13.3 (ci) <br />S. 0. G. FLOORS: Unheated F-0.510 R-10.0 (3ft) <br />OPAQUE DOORS: Swinging U-0.370 <br />OPAQUE DOORS: Non -Swinging U-0.310 <br />FENESTRATION: 0-40% Glazing U-0.340 (0.38 SHGC) <br />SUBMITTALS <br />A. Contractor To Provide Product Submittals If Requested By <br />The Building Official <br />2 Stalls PRODUCT INFORMATION AND INSTALL. REQ. <br />A. Building Components Must Identify R-Values Or U-Values Clearly <br />Labeled On The Product In Accordance With Section 5.8 <br />Proposed <br />R-30 (ci) <br />R-23 (ci) <br />R-23 <br />U-0.20 <br />U-0.147 <br />U-0.340 <br />2. Stoll Size 3. Aisle Size 4. Striping <br />- 9'-0" x 18'-0" - 24'-0" <br />5. Pavement Design <br />- All Drive Aisles And Truck Moneuvering Areas <br />2" Bituminous Weor Course <br />2" Bituminous Binder Course <br />8" Compacted Class 5 Base <br />- All Parking Areas <br />1 1/2" Bituminous Wear Course <br />1 1/2" Bituminous Binder Course <br />6" Compacted Class 5 Base <br />- Verify With Existing Soil Conditions And Adjust Accordingly <br />M. FIRE PROTECTION FOR HIGH -PILED COMB. STORAGE (IFC Chpt 32) <br />1. Moteriol Storage Height +22'-0" Per Client <br />2. Commodity Class I through IV <br />3. Total High -Piled Area - 71,875 s.f. (Primary Building) <br />13,500 s.f. (Accessory Building) <br />4. General Fire Protection and Life Safety Requirements <br />Building Component <br />Auto Fire Ext. System <br />REQUIRED <br />Fire Detection System <br />Building Access <br />REQUIRED <br />Smoke/ Heot Removal <br />REQUIRED <br />Requirement <br />According To <br />IFC 3206.4 <br />NOT REQUIRED <br />- 4" White Stripes <br />Roads Within 1507 Doors Every 125' <br />IFC 3206.6, 3206.7 <br />According To IFC 3206.8 Or <br />Provide ESFR Fire Sprinkler System <br />Solid Piled Storage, Shelf Storage and Palletized Storage <br />Maximum Pile Dimension 120 Lineal Horizontal feet <br />Maximum Storage Height 40 Lineal Vertical feet <br />Maximum Pile Volume 400,000 cubic feet <br />SHEET SCHEDULE <br />Sheet <br />T1 <br />Al <br />L1 <br />A2 <br />A3 <br />A4 <br />A5 <br />A6 <br />A7 <br />S1 <br />S2 <br />S3 <br />Description <br />Title Sheet <br />Site Plon <br />Landscape Plon <br />Floor Plon <br />Roof Pion <br />Building Elevations <br />Restroom Details & Schedules <br />Wall Sections <br />Wall Sections <br />Footing & Foundation Plan <br />Roof Framing Plon <br />Structurol Detoils <br />DEVELOPMENT TEAK <br />CONTRACTOR <br />RJRYAN <br />CONSTRUCTION <br />1100 Mendota Heights Rd <br />Mendota Heights, MN 55120 <br />Phone: 651 -681 -0200 <br />Contact: John Grotkin <br />ARCHITECT <br />LAMPERT <br />ARCHITECTS <br />550 Vandalia St. Suite 120 <br />St. Paul, MN 55114 <br />Phone: 763-755-1 21 1 <br />Contact: James Berthiaume <br />OWNER <br />WILDLIFE <br />RESEARCH <br />C E N T E R, I N C. <br />14485 Azurite St NW <br />Ramsey, MN 55303 <br />Phone: 763-241 -1 801 <br />Contact: Sam Burgeson <br />ENGINEER <br />STROH <br />ENGINEERING <br />P.O. Box 1058 <br />Jerome, AZ 86331 <br />Phone: 808-463-2256 <br />Contact: Bernie Stroh <br />ENGINEER <br />HAKANSON <br />ANDERSON <br />3601 Thurston Ave <br />Anoka, MN 55303 <br />Phone: 763-427-5860 <br />Contact: Craig Jochum <br />LAMPERT <br />ARCHITECTS <br />550 Vandalia St, Ste 120 •. <br />St. Paul, MN 55114 <br />Phone:763.755.1211 <br />lampert@lampert-arch.com <br />ARCHITECT CERTIFICATION: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED ARCHITECT UNDER THE <br />LAWS OF THE STATE OF MINNESOTA. <br />SIGNATURE <br />LEONARD LAMPERT <br />PRINT NAME <br />13669 <br />LICENSE NO. <br />07.02.26 <br />DATE <br />RJ Ryan <br />Construction, Inc. <br />Commercial Design and Construction <br />1100 Mendota Heights Road Ph: 651-681-0200 <br />Mendota Heights, MN 55120 Fax: 651-681-0235 <br />Z <br />0 <br />St NW, Ramsey, Minnesota <br />* L <br />N <br />L) <br />CO <br />Copyright 2026 <br />Leonard Lampert Architects Inc. <br />Project Designer: JAMES B <br />Drown By: JRB <br />Checked By: LL <br />Revisions <br />7/2/26 ISSUE FOR PERMIT <br />TITLE SHEET <br />Sheet Number <br />Project No. 251003-4 <br />