Laserfiche WebLink
ROOM FINISH SCHEDULE <br />RM# DESCRIPTION FLOOR BASE <br />101 WAREHOUSE CONC NONE <br />102 UNISEX CONC VINYL <br />103 WAREHOUSE CONC NONE <br />104 UNISEX CONC VINYL <br />105 MECHANICAL ROOM CONC VINYL <br />ABBREVIATIONS: <br />PT/GYP = PAINTED GYPSUM BOARD <br />GYP BD = GYPSUM BOARD TAPED AND SANDED <br />CONC = SEALED CONCRETE <br />FRP = FIBER REINFORCED PLASTIC PANELING <br />WILDLIFE RESEARCH\ADDITION\WILDLIFE RESEARCH ADDITION-A5 <br />E <br />0 <br />a� <br />N. WALL E.WALL S.WALL W.WALL <br />PRECAST PRECAST PRECAST PRECAST <br />4' FRP - SEE PLAN FOR LOCATIONS <br />PRECAST I PRECAST I PRECAST I PRECAST <br />4' FRP - SEE PLAN FOR LOCATIONS <br />PRECAST( PT/GYP PT/GYP PRECAST <br />CLG. HGHT <br />OPEN VARIES <br />PT/GYP 8'-0" <br />OPEN VARIES <br />PT/GYP 8'-0" <br />OPEN VARIES <br />DOOR & FRAME SCHEDULE <br />DR # <br />101A <br />101E <br />101C <br />101D <br />101E <br />101F <br />101G <br />101H <br />1011 <br />101J <br />101K <br />101L <br />102 <br />103A <br />103E <br />103C <br />103D <br />103E <br />103E <br />103G <br />104 <br />105 <br />NOTES: <br />DOOR SIZE <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />12'-0"x14'-0" <br />9'-0"x10'-0" <br />9'-0"x10'-0" <br />9'-0"x10'-0" <br />9'-0"x10'-0" <br />3'-0"x7'-0" <br />12'-0"x14'-0" <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />12'-0"x14'-0" <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />12'-0"x14'-0" <br />9'-0"x10'-0" <br />9'-0"x10'-0" <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />3'-0"x7'-0" <br />1-3/4" <br />1-3/4" <br />2" <br />2" <br />2" <br />2" <br />2" <br />1-3/4" <br />2" <br />1-3/4" <br />1-3/4" <br />2" <br />1-3/4" <br />1-3/4" <br />1-3/4" <br />1-3/4" <br />2" <br />2" <br />2" <br />1-3/4" <br />1-3/4" <br />1-3/4" <br />REMARKS <br />FRP AT MOP SINK <br />THICK DOOR FRAME REMARKS <br />D1 F1 INSULATED <br />D1 F1 INSULATED <br />D3 INSULATED <br />D3 INSULATED <br />D3 INSULATED <br />D3 INSULATED <br />D3 --- INSULATED <br />D1 F1 INSULATED <br />D3 --- INSULATED <br />D1 F1 INSULATED <br />D1 F1 INSULATED <br />D3 --- INSULATED <br />D1 F1 <br />D1 F1 INSULATED <br />D1 F1 INSULATED <br />D2 F2 INSULATING GLASS <br />D3 --- INSULATED <br />D3 --- INSULATED <br />D3 --- INSULATED <br />D1 F1 INSULATED <br />D1 F1 <br />D1 F1 45 MINUTE RATED <br />1. ALL DOOR HARDWARE TO BE SPECIFIED & PROVIDED BY CONTRACTOR <br />2. ALL EXIT HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, <br />OR TWISTING OF THE WRIST. MOUNT HARDWARE BETWEEN 34"-48" <br />(ANSI A117.1-404.2.6) <br />3. PROVIDE A KNOX BRAND FIRE DEPARTMENT KEY BOX AS SPECIFIED BY <br />THE FIRE MARSHAL <br />4. THE MAIN EXIT IS ALLOWED TO HAVE A KEYED LOCK PROVIDED THAT <br />THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED AND A <br />SIGN WITH 1" CONTRASTING LETTERS IS POSTED ON THE EGRESS SIDE <br />STATING: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS <br />OCCUPIED'. (IBC 1010.1.9.4) <br />❑3 <br />3-5/8" STEEL STUD WALL <br />BUILT TO 8'-0" <br />M 6" STEEL STUD WALL <br />BUILT TO 8'-0" <br />3-5/8" STEEL STUDS <br />5/8" GYPSUM BOARD <br />BATT INSULATION <br />FOR SOUND <br />6" STEEL STUDS <br />i <br />5/8" GYPSUM BOARD <br />BATT INSULATION <br />FOR SOUND <br />1 HOUR 6" METAL STUD WALL <br />One Layer 5/8" Type 'X' Gypsum Wallboard Or Gypsum Veneer Bose <br />Applied At Right Angles Or Parallel To Each Side Of 6" Steel Studs <br />24" o.c. With 1" Type S Drywall Screws 8" o.c. To Vertical Joints And <br />12" o.c. At Floor And Ceiling Runners And Intermediate Studs. Stagger <br />Joints Staggered 24" On Opposite Sides. <br />GA FILE NO. WP 1200 STC RATING = 40-44 <br />—11 <br />—k 6" STUDS ALLOWED <br />TO BE SUBSTITUTED <br />_n FOR 3-5/8" STUDS <br />WALL TYPES <br />SCALE: 1" = 1'-0" <br />—11 <br />6' - 7" <br />/ / <br />48" MIN. <br />CLEAR <br />\ FLOOR <br />SPACE <br />0"x48" CLEAR <br />FLOOR SPAC <br />• <br />ENLARGED RESTROOM PLAN <br />SCALE: 3/8" = 1'-0" <br />FURRING 5/8" GYP. <br />BD. ON 1-1/2" STL. <br />FURRING TO 8'-0" <br />DASHED LINE <br />INDICATES 4 FT. \y <br />HIGH FRP WAINSCOT <br />6" PLUMBING WALL <br />FURRING 5/8" GYP. <br />BD. ON 1-1/2" STL. <br />FURRING TO 8'-0" <br />UTILITY SINK <br />1'-6" <br />30"" <br />sap z CLEARx48 <br />FLOOR <br />SPACE <br />7'-4" <br />60" MIN. <br />7 <br />�I6"-18" <br />\ J <br />\30"x48" \ <br />CLEAR <br />FLOOR <br />\ SPACE <br />/ <br />z <br />03 <br />• <br />ENLARGED RESTROOM PLAN <br />SCALE: 3/8" = 1'-0" <br />GRAB BARS <br />GRAB BARS SHALL BE 1 1/4"-2" IN DIAMETER. THE SPACE BETWEEN THE GRAB BAR AND THE WALL SHALL BE 1 1/2". A <br />1 1/2" MINIMUM CLEARANCE SHALL BE PROVIDED BELOW AND AT END OF THE GRAB BAR. A 12" MINIMUM CLEARANCE SHALL <br />BE PROVIDED ABOVE THE GRAB BAR EXCEPT AT SHOWER CONTROLS. GRAB BARS SHALL NOT ROTATE IN THEIR FITTING AND <br />SHALL SUPPORT 250 POUNDS MINIMUM. <br />FLUSH CONTROLS <br />FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED CONTROLS SHALL COMPLY WITH REQUIREMENTS <br />FOR ACCESSIBLE OPERABLE PARTS. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET, EXCEPT <br />IN AMBULATORY ACCESSIBLE COMPARTMENTS WHERE CONTROLS ARE PERMITTED ON EITHER SIDE OF THE WATER CLOSET. <br />ACCESSORIES <br />ALL WALL -MOUNTED DISPENSERS, WASTE DISPOSAL CONTAINERS, OR SIMILAR TOILET ACCESSORIES SHALL BE MOUNTED SO <br />THAT THE OPERABLE PORTIONS OF SUCH ACCESSORIES COMPLIES WITH AN UNOBSTRUCTED FRONT OR SIDE REACH. THE <br />MAXIMUM UNOBSTRUCTED REACH RANGE IS BETWEEN 15" AND 48" ABOVE THE FINISHED FLOOR. OBSTRUCTIONS PROTRUDING <br />20-25 FROM A WALL SHALL LIMIT THE HIGH REACH TO 44" MAXIMUM ABOVE THE FINISHED FLOOR. <br />INTERIOR FINISHES <br />FLOORS IN TOILET, SHOWER, AND BATHING ROOMS ACCESSIBLE TO THE PUBLIC SHALL HAVE A SMOOTH, HARD <br />NON -ABSORBENT SURFACE SUCH AS CERAMIC TILE AND SHALL EXTEND UP THE WALLS AT LEAST 4". (IBC 1209.2.1) WALLS <br />WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD NON -ABSORBENT SURFACE, TO 4 FEET <br />A.F.F. (IBC 1209.2.2) SHOWER COMPARTMENT AND BATHTUB WALLS WITH SHOWER HEADS SHALL HAVE A SMOOTH, HARD <br />NON -ABSORBENT SURFACE SUCH AS CERAMIC TILE TO 72" ABOVE THE DRAIN. (IBC 1209.2.3) <br />SIGN AGE <br />IDENTIFICATION SIGNAGE SHALL BE PROVIDED AT TOILET ROOMS, <br />THE SIGNAGE SHALL INCLUDE TACTILE LETTERS INDICATING THE <br />NAME OF THE SPACE, THE INT'L SYMBOL OF ACCESSIBILITY, <br />AND BRAILLE CHARACTERS ACCORDING TO CHAPTER 703. <br />MOUNT THE SIGN CENTERED AT 9" FROM THE LATCH SIDE OF <br />THE DOOR AND MOUNT THE SIGN 48"-60" ABOVE THE FIN. FLR. <br />WITH AN 18"X18" CLEAR FLOOR SPACE CENTERED ON THE SIGN <br />36"I <br />MIN/ <br />12" <br />/MIN'' 1IN <br />4" <br />BACK WALL <br />SIDEWALL GRAB BARS <br />REQ'D AT AMBULATORY <br />STALL <br />FLUSH CON-ROL <br />03 <br />0 <br />• <br />• <br />z <br />• <br />• <br />CO <br />I <br />N <br />t " <br />z <br />AREA FOR <br />OPERABLE PARTS OF <br />DISPENSERS AND RECEPTACLE <br />39"-41" <br />42" 12" <br />i' / <br />MIN MAX <br />24" <br />MIN <br />SIDE WALL <br />GRAB BARS AND ACCESSIBLE WATER CLOSETS <br />HOLLOW METAL <br />D1 PAINTED <br />T <br />X <br />-/—/ -co- 0 <br />co <br />NOTE: <br />PROVIDE A <br />PROTECTIVE <br />COATING OR <br />COVER FOR <br />PIPING <br />8„ <br />MIN <br />11" /�6' <br />MIN MAX <br />17"-25" <br />/ / <br />LAVATORY CLEARANCES <br />rr <br />MIRROR <br />RESTROOM DETAILS AND NOTES <br />SCALE: 3/8" = 1'-0" <br />®ANODIZED <br />ALUMINUM <br />DOOR TYPES <br />SCALE: 1/4" = 1'-0" <br />®UPWARD ACTING <br />SECTIONAL DOOR <br />T = TEMPERED GLASS <br />• <br />• <br />X <br />0 <br />2' SEE SCHD 2" <br />N <br />N O <br />1 <br />F1 PAINTED <br />HOLLOW METAL <br />DOOR FRAME TYPES <br />SCALE: 1/4" = 1'-0" <br />2' SEE SCHD <br />ANODIZED <br />ALUMINUM <br />LAMPERT <br />ARCHITECTS <br />550 Vandalia St, Ste 120 <br />St. Paul, MN 55114 <br />Phone:763.755.1211 <br />lampert®lampert—arch.com <br />ICI <br />ARCHITECT CERTIFICATION: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED ARCHITECT UNDER THE <br />LAWS OF THE STATE OF MINNESOTA. <br />SIGNATURE <br />LEONARD LAMPERT <br />PRINT NAME <br />13669 <br />LICENSE NO. <br />07.02.26 <br />DATE <br />Construction, Inc. <br />Commercial Design and Construction <br />1100 Mendota Heights Road <br />Mendota Heights, MN 55120 <br />W <br />LL <br />J <br />J <br />Ph: 651-681-0200 <br />Fax: 651-681-0235 <br />St NW, Ramsey, Minnesota <br />1 <br />L <br />N <br />L <br />CO <br />Copyright 2026 <br />Leonard Lampert Architects Inc. <br />Project Designer: JAMES B <br />Drawn By: JRB <br />Checked By: LL <br />Revisions <br />7/2/26 ISSUE FOR PERMIT <br />RESTROOM <br />DETAILS & <br />SCHEDULES <br />Sheet Number <br />Project No. 251003-4 <br />