Laserfiche WebLink
6'— 7" <br />48" MIN. <br />ROOM FINISH SCHEDULE <br />RM# <br />DESCRIPTION <br />FLOOR <br />BASE <br />N.WALL <br />E.WALL <br />S.WALL <br />W.WALL <br />CLG. <br />HGHT <br />REMARKS <br />101 <br />WAREHOUSE <br />CONC <br />NONE <br />PRECAST <br />PRECAST <br />PRECAST <br />PRECAST <br />OPEN <br />VARIES <br />— <br />102 <br />UNISEX <br />CONC <br />VINYL <br />4' FRP — SEE PLAN FOR LOCATIONS <br />PT/GYP <br />8'—O" <br />— <br />103 <br />WAREHOUSE <br />CONC <br />NONE <br />PRECAST <br />PRECAST <br />PRECAST <br />PRECAST <br />OPEN <br />VARIES <br />FRP AT MOP SINK <br />104 <br />UNISEX <br />CONC <br />VINYL <br />4' FRP — SEE PLAN FOR LOCATIONS <br />PT/GYP <br />8'-0" <br />— <br />105 <br />MECHANICAL ROOM <br />CONC <br />VINYL <br />PRECAST <br />PT/GYP <br />PT/GYP <br />PRECAST <br />OPEN <br />VARIES <br />— <br />ABBREVIATIONS: <br />PT/GYP = PAINTED GYPSUM BOARD <br />GYP BD = GYPSUM BOARD TAPED AND SANDED <br />CONC = SEALED CONCRETE <br />FRP = FIBER REINFORCED PLASTIC PANELING <br />WILDLIFE RESEARCH\ADDITION\WILDLIFE RESEARCH ADDITION-A5 <br />iv <br />E <br />0 <br />c <br />0 <br />L <br />DOOR & FRAME SCHEDULE <br />DR # <br />DOOR SIZE <br />THICK <br />DOOR <br />FRAME <br />REMARKS <br />101A <br />3'-0"x7'—O" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />101E <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />101C <br />12'-0"x14'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />101D <br />9'-0"x10'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />101E <br />9'-0"x10'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />101F <br />9'-0"x10'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />101G <br />9'-0"x10'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />101H <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />1011 <br />12'-0"x14'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />101J <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />101K <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />101L <br />12'-0"x14'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />102 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />103A <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />103B <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />103C <br />3'-0"x7'-0" <br />1-3/4" <br />D2 <br />F2 <br />INSULATING GLASS <br />103D <br />12'-0"x14'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />103E <br />9'-0"x10'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />103E <br />9'-0"x10'-0" <br />2" <br />D3 <br />--- <br />INSULATED <br />103G <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />INSULATED <br />104 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />105 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />45 MINUTE RATED <br />NOTES: <br />1, ALL DOOR HARDWARE TO BE SPECIFIED & PROVIDED BY CONTRACTOR <br />2. ALL EXIT HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, <br />OR TWISTING OF THE WRIST. MOUNT HARDWARE BETWEEN 34"-48" <br />(ANSI A117.1-404.2.6) <br />3. PROVIDE A KNOX BRAND FIRE DEPARTMENT KEY BOX AS SPECIFIED BY <br />THE FIRE MARSHAL <br />4, THE MAIN EXIT IS ALLOWED TO HAVE A KEYED LOCK PROVIDED THAT <br />THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED AND A <br />SIGN WITH 1" CONTRASTING LETTERS IS POSTED ON THE EGRESS SIDE <br />STATING: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS <br />OCCUPIED'. (IBC 1010.1,9.4) <br />❑3 3-5/8" STEEL STUD WALL <br />BUILT TO 8'-0" <br />3-5/8" STEEL STUDS <br />5/8" GYPSUM BOARD <br />BATT INSULATION <br />FOR SOUND <br />a 6" STEEL STUD WALL <br />BUILT TO 8'-0" <br />6" STEEL STUDS <br />5/8" GYPSUM BOARD <br />BATT INSULATION <br />FOR SOUND <br />1 HOUR 6" METAL STUD WALL <br />One Layer 5/8" Type 'X' Gypsum Wallboard Or Gypsum Veneer Base <br />Applied At Right Angles Or Parallel To Each Side Of 6" Steel Studs <br />24" o.c. With 1" Type S Drywall Screws 8" o.c. To Vertical Joints And <br />12" o.c, At Floor And Ceiling Runners And Intermediate Studs. Stagger <br />Joints Staggered 24" On Opposite Sides. <br />GA FILE NO. WP 1200 STC RATING = 40-44 <br />6" STUDS ALLOWED <br />TO BE SUBSTITUTED <br />FOR 3-5/8" STUDS <br />WALL TYPES <br />A5 <br />SCALE: 1" = 1'-0" <br />"J'AD <br />30"x48"\ <br />CLEAR \ <br />\ FLOOR <br />SPACE <br />0F.D. <br />/ F,D. <br />30"x48" CLEAR <br />FLOOR SPAC <br />1'-6„ <br />MIN <br />ENLARGED RESTROOM PLAN <br />SCALE: 3/8" = 1'-0" <br />FURRING 5/8" GYP, <br />BD. ON 1-1/2" STL. <br />FURRING TO 8'-0" <br />DASHED LINE <br />INDICATES 4 FT, <br />HIGH FRP WAINSCOT <br />6" PLUMBING WALL <br />FURRING 5/8" GYP. <br />BD. ON 1-1/2" STL. <br />FURRING TO 0" <br />UTILITY UTILITY SINK <br />7'-4" <br />1'-6" <br />60" MIN. <br />io <br />30"x48" <br />CLEA <br />FLOG <br />SPACE <br />J <br />o F.D. <br />/30"x48" <br />CLEAR <br />FLOOR <br />\ SPACE <br />16"-18 <br />ENLARGED RESTROOM PLAN <br />SCALE: 3/8" = 1'-0" <br />GRAB BARS <br />GRAB BARS SHALL BE 1 1/4"-2" IN DIAMETER. THE SPACE BETWEEN THE GRAB BAR AND THE WALL SHALL BE 1 1/2". A <br />1 1/2" MINIMUM CLEARANCE SHALL BE PROVIDED BELOW AND AT END OF THE GRAB BAR. A 12" MINIMUM CLEARANCE SHALL <br />BE PROVIDED ABOVE THE GRAB BAR EXCEPT AT SHOWER CONTROLS. GRAB BARS SHALL NOT ROTATE IN THEIR FITTING AND <br />SHALL SUPPORT 250 POUNDS MINIMUM. <br />FLUSH CONTROLS <br />FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED CONTROLS SHALL COMPLY WITH REQUIREMENTS <br />FOR ACCESSIBLE OPERABLE PARTS. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET, EXCEPT <br />IN AMBULATORY ACCESSIBLE COMPARTMENTS WHERE CONTROLS ARE PERMITTED ON EITHER SIDE OF THE WATER CLOSET. <br />ACCESSORIES <br />ALL WALL —MOUNTED DISPENSERS, WASTE DISPOSAL CONTAINERS, OR SIMILAR TOILET ACCESSORIES SHALL BE MOUNTED SO <br />THAT THE OPERABLE PORTIONS OF SUCH ACCESSORIES COMPLIES WITH AN UNOBSTRUCTED FRONT OR SIDE REACH. THE <br />MAXIMUM UNOBSTRUCTED REACH RANGE IS BETWEEN 15" AND 48" ABOVE THE FINISHED FLOOR. OBSTRUCTIONS PROTRUDING <br />20-25 FROM A WALL SHALL LIMIT THE HIGH REACH TO 44" MAXIMUM ABOVE THE FINISHED FLOOR. <br />INTERIOR FINISHES <br />FLOORS IN TOILET, SHOWER, AND BATHING ROOMS ACCESSIBLE TO THE PUBLIC SHALL HAVE A SMOOTH, HARD <br />NON —ABSORBENT SURFACE SUCH AS CERAMIC TILE AND SHALL EXTEND UP THE WALLS AT LEAST 4", (IBC 1209,2,1) WALLS <br />WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD NON —ABSORBENT SURFACE, TO 4 FEET <br />A.F.F. (IBC 1209.2.2) SHOWER COMPARTMENT AND BATHTUB WALLS WITH SHOWER HEADS SHALL HAVE A SMOOTH, HARD <br />NON —ABSORBENT SURFACE SUCH AS CERAMIC TILE TO 72" ABOVE THE DRAIN. (IBC 1209.2.3) <br />SIGNAGE <br />IDENTIFICATION SIGNAGE SHALL BE PROVIDED AT TOILET ROOMS, <br />THE SIGNAGE SHALL INCLUDE TACTILE LETTERS INDICATING THE <br />NAME OF THE SPACE, THE INT'L SYMBOL OF ACCESSIBILITY, <br />AND BRAILLE CHARACTERS ACCORDING TO CHAPTER 703. <br />MOUNT THE SIGN CENTERED AT 9" FROM THE LATCH SIDE OF <br />THE DOOR AND MOUNT THE SIGN 48"-60" ABOVE THE FIN. FLR. <br />WITH AN 18"X18" CLEAR FLOOR SPACE CENTERED ON THE SIGN <br />36" <br />SIDEWALL GRAB BARS <br />REQ'D AT AMBULATORY <br />STALL <br />FLUSH CONTROL <br />MIN <br />12" <br />4" <br />MIN <br />IN <br />M <br />M <br />BACK WALL <br />39"— 41" <br />42" 12" <br />/ / <br />MIN MAX <br />r\ <br />Z_ <br />M <br />I <br />J) <br />Pr) <br />r 42„), <br />3 24" <br />IN <br />MA <br />AREA FOR SIDE WALL <br />OPERABLE PARTS OF <br />DISPENSERS AND RECEPTACLE <br />GRAB BARS AND ACCESSIBLE WATER CLOSETS <br />9"� <br />0 <br />x <br />0 <br />co <br />NOTE: <br />PROVIDE A <br />PROTECTIVE <br />COATING OR <br />COVER FOR <br />PIPING <br />MIRROR <br />MIN <br />11 <br />0) <br />N <br />X <br />0 <br />6" <br />MIN MAX <br />17"-25' <br />LAVATORY CLEARANCES <br />3 RESTROOM DETAILS AND NOTES <br />SCALE: 3/8" = 1'—O" <br />T <br />HOLLOW METAL ANODIZED <br />D1 PAINTED ® ALUMINUM <br />4 DOOR TYPES <br />= 1'-0 <br />®UPWARD ACTING <br />SECTIONAL DOOR <br />A5 SCALE: 1/4" <br />T = TEMPERED GLASS <br />2' SEE SCHD..2" <br />N <br />2' SEE SCHD..2" <br />F1 PAINTED <br />HOLLOW METAL <br />DOOR FRAME TYPES <br />A5 % SCALE: 1/4" = 1'-0" <br />ANODIZED <br />ALUMINUM <br />LAMPERT <br />ARCHITECTS <br />550 Vandalia St, Ste 120 •�• <br />St. Paul, MN 55114 iUi <br />Phone:763.755.1 21 1 <br />lampert®lampert—arch.com <br />ARCHITECT CERTIFICATION: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED ARCHITECT UNDER THE <br />LAWS OF THE STATE OF MINNESOTA. <br />SIGNATURE <br />LEONARD LAMPERT <br />PRINT NAME <br />13669 <br />LICENSE NO. <br />07.02.26 <br />DATE <br />Construction, Inc. <br />Commercial Design and Construction <br />1100 Mendota Heights Road <br />Mendota Heights, MN 55120 <br />Ph: 651-681-0200 <br />Fax: 651-681-0235 <br />Z <br />O <br />W <br />J <br />J <br />St NW, Ramsey, Minnesota <br />a--+ <br />1:N <br />Q <br />L J <br />co <br />Copyright 2026 <br />Leonard Lampert Architects Inc. <br />Project Designer: JAMES B <br />Drawn By: JRB <br />Checked By: LL <br />Revisions <br />7/2/26 <br />ISSUE FOR PERMIT <br />RESTROOM <br />DETAILS & <br />SCHEDULES <br />Sheet Number <br />Project No. 251003-4 <br />