Laserfiche WebLink
Minimum Fire Code # Complete Operational Analysis <br />APPENDIX D ACCESS WIDTH <br />The Appendix D table used here prescribes 20 feet through 500 feet and 26 feet for the 501-750-foot dead-end category. For roads over 750 feet, special approval is <br />required rather than one prescribed standard width. <br />AERIAL OPERATING FOOTPRINT <br />Published online specifications for a comparable same -generation RK 104-foot aerial platform on a Spartan Gladiator chassis report approximately 18'5" of full <br />outrigger/stabilizer spread. <br />MOBILE WATER -SUPPLY LANE REFERENCE <br />NFPA 1142 uses a 12-foot minimum clear width for each lane of travel on roadways providing access to required water supplies. Its water -shuttle guidance also <br />recognizes the benefit of one-way shuttle routes where possible so apparatus do not have to pass one another on narrow roads. <br />Operating element <br />Width <br />Comparable RK 104 full stabilizer spread <br />NFPA 1142 clear lane reference <br />Combined side -by -side comparison <br />Appendix D 501-750 ft roadway <br />Difference <br />18'5" <br />12'0" <br />30'5" <br />26'0" <br />4'5" <br />WHAT THE GEOMETRY DEMONSTRATES <br />The combined comparison is approximately 30'5" — about 4'5" wider than Appendix D's 26-foot roadway. This is not presented as an NFPA requirement that a <br />12-foot tender lane must always exist beside a deployed aerial. It demonstrates that minimum access -road width and simultaneous fireground operating space <br />are different questions. <br />IDEAL CONDITIONS ASSUMED <br />This is before snow accumulation/storage, parked vehicles, retaining walls or constrained shoulders, hose lines, personnel, open compartments, <br />stabilizer pads, disabled vehicles, construction, a downed tree or powerline, utility work, or another obstruction. <br />WHY A MINIMUM IS A BASELINE <br />Minimum fire -access requirements are a baseline rather than a complete substitute for local street -design policy. Minnesota State Fire Code is one <br />variable alongside Police/EMS access, Public Works maintenance, engineering, connectivity, infrastructure and local operating conditions. <br />Fire Code should inform Ramsey's street policy. It should not substitute for Ramsey's street policy. <br />Future -apparatus note: U.S. fire apparatus have generally trended larger and heavier over recent decades as cabs, equipment, tanks, emissions systems and all -hazards capabilities expanded. <br />Some departments intentionally specify smaller apparatus for constrained streets. This packet does not assume Ramsey's future aerial will necessarily be larger; future apparatus should not be <br />assumed to make operating -space concerns disappear, and long-lived street design should consider actual and reasonably foreseeable emergency -vehicle dimensions. <br />Technical disclaimer: Ramsey Aerial 21's individual factory build sheet has not been located. The approximately 18'5" stabilizer dimension is drawn from published online specifications for a <br />comparable same -generation RK 104-foot platform / Spartan Gladiator apparatus and should be verified against Ramsey's actual apparatus manual/build specification before being treated as an <br />exact Ramsey measurement. The 12-foot figure is an NFPA 1142 clear -lane reference; the 30'5" calculation is an illustrative operating -space comparison, not a standalone code -mandated combined <br />width. <br />Aooendix D table source <br />Fire. Enaineenna — comnarahle RK 104 / Spartan Gladiator <br />NFPA 1142 reference <br />FAMA— Emeraencv Vehicle Size & Weiaht Guide <br />USDOT/Volne — Downsizing Fire Annaratus <br />Fire Code minimums + operational geometry <br />