Laserfiche WebLink
rectangular-shaped, similar to the lot it will be built upon, with the building facade positioned closest to Sunwood <br />Drive and Yolite Street. In lieu of the building facade being located within 20 feet of the Sunwood Drive <br />right-of-way line, the site plan includes a large sidewalk patio along the front edge of the building, surrounded by <br />a decorative fence that will run along the north property line for about 45.8 feet. When measuring the length of <br />the 45.8-foot-long fence along Sunwood Drive, in comparison to the building width of 57 feet, it equals 80.35% <br />of the building facade (or, in this case, an ornamental fence surrounding an outdoor seating area) within the 5-foot <br />build-to line along Sunwood Drive. Additionally, though it is no longer required in accordance with Ordinance <br />#26-16, the building also meets the build-to line requirement of 5 feet along Yolite Street by the inclusion of a <br />second fence along the Yolite Street property line to define the edge of a secondary outdoor patio and small <br />playground. The proposed development has approximately 72% impervious area, including the building footprint, <br />parking lot, and outdoor patios, which is consistent with other developments in the COR. <br />The building is designed to have four main entrances: two secure entrances to the apartments on the second floor <br />(one along the south wall, and one along the east wall, both connected to sidewalks leading to the parking lot south <br />of the building) and two entrances to the commercial space on the first floor (one in the northwest corner to access <br />the gathering space, and the other along the west wall to directly access the coffee shop). The north and west <br />building facades are accented with outdoor patios to activate the storefront. The patios and the building are <br />slightly elevated from the grade of the adjacent public sidewalks due to the site's existing elevation. In addition to <br />the main entrances to the building, there are garage-style doors proposed along the north building facade, opening <br />the indoor gathering space up to the north outdoor patio. There is also a service door along the south building <br />facade to access the back-of-house space for the coffee shop. Vehicular access to the Subject Property will come <br />from a driveway along Yolite Street. The building placement and landscape buffer are intended to screen the <br />parking lot from all adjacent streets. Additionally, a trash enclosure will be located along the south edge of the <br />building, using materials that complement the building facade. <br />The minimum parking requirements for apartment units are 1.5 stalls per unit. Additionally, retail shopping uses <br />require one parking stall for each 200 square feet of floor space for retail uses under 20,000 square feet in area. <br />Office spaces require one parking stall for each 300 square feet of floor space. Lastly, restaurants (including the <br />coffee shop) have a minimum parking requirement of one stall per three seats of design capacity. Based on the <br />proposed 3 apartment units, 16 seats in the coffee seating area, 12 seats in the outdoor patio area, 391 square feet <br />of dedicated retail space for artist exposition sales, 445 square feet for office space, and 1,904 square feet of <br />gathering space, a total of 27 parking stalls would be required. However, the Applicant submitted a parking <br />narrative that explains their anticipated parking demand, which includes the following: <br />1 parking stall per apartment unit x 3 apartment units = 3 parking stalls <br />1 parking stall per coffee shop employee x 2 onsite employees = 2 parking stalls <br />Note: the intent of the skills training program is to employ the apartment residents at the coffee shop. <br />1 parking stall per 3 seats of restaurant seating capacity x 28 seats = 10 parking stalls <br />1 parking stall per 200 square feet of retail space (for the artist wares) x 391 square feet = 2 parking stalls <br />3 additional parking stalls for the office/break room area <br />TOTAL: 20 parking stalls required (20 provided) <br />If general parking requirements exceed supply, there are several on-street parking spaces along Sunwood Drive <br />and Veterans Drive to accommodate any overflow of retail customers or visitors. <br />Architecture and Building Elevations <br />The building will be two stories tall. The building's overall height (as measured from the finish floor elevation to <br />the top of the parapet) is 26 feet. The building facade will consist of glass overhead doors along the north outdoor <br />patio, and storefront windows and brick veneer along the first floor, plus lap siding along the entirety of the <br />second floor. The building facade is designed with 52.8% brick veneer and exterior split face veneer, which meets <br />the requirement that at least 50% of the total building facade not covered by windows consists of brick veneer, <br />exterior split face block, or a similar material, as required by the architectural standards for the COR-1 district in <br />the COR Framework. In addition to the building itself, the Applicant is proposing to install pergolas over the north <br />outdoor patio, in line with the overhead doors. <br />Signage <br />As noted during the development and adoption of Chapter 108, Ramsey's Sign Code, signage in the COR will be