Laserfiche WebLink
I <br /> <br /> I <br /> I <br /> I. <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />Site Plan Review: <br />Page 2 of 4 <br /> <br />Rivenwick 3rd Addition <br /> <br />The private streets meet City Code requirements. . <br /> <br />Townhouse size: The site plan is providing six and eight unit Structures. <br />townhouse unit to be a certain size based on the number of bedrooms the unit will contain. <br /> <br />I bedroom 700 square feet <br />2-bedroom 800 square feet <br />3 bedroom 960 square feet <br /> <br />City Code requ/res each <br /> <br />Information provided to staff indicates that. the smallest unit will, be 1,078 sqUare feet in size. <br />proposed townhome units exceed City Code requirements~ <br /> <br />Setbacks: The proposed development is subject to the following Setbacks: <br /> <br />Building setback from public street 25 feet <br />right of way <br />Building setback from private street 25 <br />Building setback from exterior 30.feet <br />development boundary line <br />Setback from building to building 20-feet <br /> <br />-185-. <br /> <br />"r~e <br /> <br />information. <br /> <br />Grading and Drainage: A detailed ~ading and drainage Plan_ is being addressed as Part of the <br />preliminary plat for Rivenwick yd Addition. <br /> <br />The proposed development meets or exceeds all of the reqUired setbacks: It should be noted that these <br />setbacks are applicable to any appurtenances of the structure such as decks or patios. <br /> <br />Structure lteight: City Code restricts the building height to 35 feet.- Staff will' need to be provided with <br />plans outlining the building height of the proposed townhouse structures. Staff anticipates that the <br />proposed townhouse units will meet the 35 foot height restriction. ·: <br /> <br />Parking NOde Setback: City Code requires ail Parking nodes to be'a minimum of 30-feet from the <br />exterior development boundary line. The R-2 District als° requires a 15-foot parking node setback from <br />each townhouse structure. The site plan complies with parking.node setback requirements. <br /> <br />Off-Street Parkin~ Requ.riements: The proposed development is required to provide a minimUm of <br />224 off-street parking stalls (2 parking stalls per unit). The proposed townhoUse units will have either a <br />one stall or a two stall' garage and all units are required: to provide a driveway 25 feet'in length. The <br />proposed garage and. driveway pad. will' provide enough area for 2 off-street parking stalls. The site plan <br />is also providing for 42 ·additional parking spaces located Within parking nodes throughout the <br />development. ' · <br /> <br />Maximum Driveway Width: The maximum driveway width permitted for each unit is 20-feet. The site <br />plan appears to meet this requirement, however the site plan ShoUld be revised to include this <br /> <br /> <br />