Laserfiche WebLink
iv. <br /> <br />aa-l-. <br /> <br />Existing and proposed, grades with a <br />minimum of two foot contour intervals to a <br />known sea level datum; <br /> <br />b.__~. Sufficient spot elevations on all proposed <br /> hard surface areas; <br /> <br />c__qg. Estimated runoffof the area based on 10 and <br /> 100 year storm events; <br /> <br />Provisions to carry runoff to the nearest <br />adequate outlet, such as storm drain, natural <br />drainage way, or street; <br /> <br />ee~:. <br /> <br />Location of proposed ponding areas, <br />indicating the size and depth of the pond and <br />amount, of acre feet of water to be stored; <br /> <br />t'~. Finished floor elevations of all buildings; <br /> <br />Identify soils by type and location, including <br />identification of the water table, and <br />suitability of soil for the proposed <br />development; and <br /> <br />~hh. <br /> <br />Identify any areas located in a flood hazard <br />zone as identified by the Department of <br />Natural Resources. <br /> <br />Topographic Map. The topographic map shall be <br />drawn at a scale of one inch equals 100 feet and <br />shrill contain the following information: <br /> <br />-1-aa. Two foot contour intervals; <br /> <br />gbb. Indicate water courses, rock outcroppings, <br /> and other significant land features; and <br /> <br />ccg. Use U.S. Geological Service datum for <br /> mapping. <br /> <br />Floor Plans and Elevations. All floor plans and <br />elevations shall be drawn to a legible scale and <br />include the following information: <br /> <br />Ramsey Town Center District <br />July 2003 revisions <br /> <br />page 18 <br /> <br />166 <br /> <br /> <br />