My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 10/13/2009
Ramsey
>
Public
>
Agendas
>
Council
>
2009
>
Agenda - Council - 10/13/2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 4:22:09 PM
Creation date
10/8/2009 12:00:00 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
10/13/2009
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Number of Bedrooms <br />Minimum Septic Tank requirements <br />and Liquid Capacities (gallons)* <br />2 or less <br />1,000 with effluent filter <br />3 or 4 <br />1500 with 2 compartments or multiple <br />tanks with equivalent liquid capacity <br />5 or 6 <br />2,000 with 2 compartments or multiple <br />tanks with equivalent liquid capacity <br />For seven or more bedrooms, <br />The septic tank shall be sized as an <br />other establishment. <br />C. Table II in Part 7080.0130, subp. 3.A. is amended to read as follows: <br />Table II <br />*Systems designed with aerobic tanks must be equipped with trash traps sized according to the <br />manufacturer =s recommendations instead of the requirements specified in the table. <br />D. Table I in Part 7080.0125, supb. 2. is amended by deletion of columns "II," and "III," and the <br />footnote. <br />E. Part 7080.0150,subp.3.D. is amended to read: Perforations must be no smaller than 1/8 inch <br />diameter and no larger than 1/4 -inch diameter. Perforations 5/32 inch in diameter or smaller must <br />have orifice shields and pumps equipped with effective filters. <br />F. Table IV in Part 7080.0170,subp.1.F.is amended to add the word (occupied) following Building on <br />the third line of the table. <br />G Part 7080.0170,subp.2B.(3) is amended to read: If gravelless drainfield pipe is used, lineal feet of <br />piping must be increased 50% or pretreatment provided. Effluent filters are not considered <br />pretreatment. <br />H. Part 7080.0170, Subp.2. Table Va is amended to change the absorption ratio for mounds with fine <br />sand soil texture and single grain soil structure from 1.0 to 2.0. <br />1. Part 7080.0178 is amended to add subp.2.D. to read: be designed to incorporate timed dosing <br />when a pumping tank is utilized. <br />J. Part 7080.0178 is amended to add subp.4 to read: Other Systems are allowed for reconstruction <br />and new construction only when it can be shown that a standard system can not be constructed or <br />is not the best choice. <br />K Part 7080.0179 is amended to add subp.3 to read: Performance systems are allowed for <br />reconstruction and new construction only when it can be shown that a standard system can not be <br />constructed or is not the best choce. <br />L. Part 7080.0179 is amended to add subp.2.C.(4) to read: Performance systems must provide at least <br />the same quality of sewage treatment that would be achieved by dispersing the septic tank effluent <br />through three feet of natural unsaturated soil. <br />M. Part 7080.0179. Subp.2.C. (2) is amended to read: With Tess than 12 inches of unsaturated soil, <br />fecal coliforms cannot exceed an average of 200 colonies per 100 ml or background <br />-3- <br />
The URL can be used to link to this page
Your browser does not support the video tag.