My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 07/23/2002
Ramsey
>
Public
>
Agendas
>
Council
>
2002
>
Agenda - Council - 07/23/2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 11:09:35 AM
Creation date
9/3/2003 1:48:37 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
07/23/2002
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> I <br /> I <br /> I <br />'1 <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> ! <br /> <br />Final Plat Review: Sunflower Ridge <br />July 19, 2002 <br />Page 5 of 7 <br /> <br />Fl: <br /> <br />· Show all easements that are necessary for construction and ongoing maintenance of <br /> forcemain. It appears that the forcemain between Stations 12 + 70 and the existing <br /> MH on Alpine Drive N.W. will be difficult to install in the current r/g12t-of-way. <br />· Provide information on the construction technique required to install the forcemain <br /> within the current right-of-way. <br /> Provide a traffic control plan. <br />· Show detailed information at each utility crossing, the vertical separation of 18 inches <br /> must be maintained as well as insulation for the watermain. <br />· The minimum depth of cover must be 7.5 feet for the forcemain. <br />· Construct external drop at existing Mit on A/pine Drive. <br /> <br />LI: <br /> <br />· There are no submittals regarding the electrical control panel. These specifications <br /> should be submitted and are subject to review by the City Engineer. <br />· The guide bar bracket must be constructed using a non-sparking mater/al. <br />· The concrete fillet which creates the sump should be increased to a 12 inch height <br /> with a 1:1 side slope. <br /> <br />Specifications: <br /> <br />· Include the Standard General Conditions of the Construction Contract. Review of the <br /> Supplementary Condition cannot be completed until receipt of those General <br /> Conditions. <br />· In Section 2270-1 of the Specifications, the Erosion Control Implementation Schedule <br /> says removal of silt fence is "by others". Please revise to state "by DevelOper". <br />· Governing specifications shall be the 2000 Edition of MnDOT's Standard <br /> Specification for Construction. <br />· On Page 2500-2, Item 7 should include the installation of infishield wraps, a <br /> minimum thickness of 60 mi, to control infiltratiorffinflow. It shall also add a <br /> provision about marking all MH and valves outside paved surfaces with a green or <br /> blue carconite stake after grade is established. A/so, as should be mentioned on the <br /> detail for standard MHs, there shall be at least 2 inches of adjusting rings, and a <br /> maximum of 10 inches of adjustment rings. <br />· On Page 2612-1, under Section 2611.1A, last paragraph shall read: "When it <br /> becomes necessary for water to be shut down, the City of Ramsey will operate any <br /> and all valves to complete the shutdown. Opening or closing any valves will be done <br /> <br />-165- <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.