My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/25/2002
Ramsey
>
Public
>
Agendas
>
Council
>
2002
>
Agenda - Council - 06/25/2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 11:09:16 AM
Creation date
9/3/2003 2:13:42 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/25/2002
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
365
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> I <br /> I <br /> I <br />'1 <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br />I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> <br />JUM.20.S002 2:58PM <br /> <br />HO.?81 P.~/4 <br /> <br />I----~ Hakanson <br /> Anderson <br /> Assoc., Irlc. <br /> <br />MEMORANDUM <br /> <br />3601 Thurston Avenue, Suite 101, Anoka, MN 55303 <br />Phone: 763/427.5860 F~x: 76:~/427-0520 <br /> <br />To: Brian Olson, City Engineer <br />From: Craig Jochum <br />Date: June 20, 2002 <br />Re: Construction & Grading Plan Review for Highlands At River Park 2nd Addition <br />Cc: Dwight Jelle, P.E., Rick Packer <br /> <br />The following is a list of our comments regarding the plat review for Highlands At River <br />Park: <br />.SANITARY SEWER AND WATERMAIN C~NSTRUCTION PLANS(SHEETS 4 TO 8) <br /> <br />Sanitary sewer and watermain v~hich extend past the plat line must be within <br />a drainage and utility easement., <br /> <br />2. Call out class of watermain. All Watermain shall be class 52. <br /> <br />3. Southeast invert of MH-36 shall I~e labeled as "DROP IE". <br /> <br />Consider insulating the watermain on Xkimo Street NW at approximate <br />station 34+75. Revise plan to p~,ovide t.5' clearance between storm sewer <br />and watermain. <br /> <br />o <br /> <br />Verify clearance between waterr~ain and storm sewer structures. It appears <br />that there may be conflicts on Xl~imo Street NW at approximate station 34+80. <br />~erify clearance on all structure's) <br /> <br />We suggest eliminating the 45o bends shown in the sanitary sewer services <br />for Lot 7, Block 4 and Lot 1, Block 3, and Lots 1 l, 13, 14 of Block 2. <br /> <br />Sheet 7 is incorrectly labeled as[Yakima Court South. Revise to Yakima <br />Court North. (Sheet 11 is also r~islabeled) <br /> <br />The invert elevation of the stub tb the south of. MH-43 on sheet 7 appears to <br />be incorrect. Please revise. <br /> <br />STORM SEWER__AN_O_STREET C_O_.NSTR~ICTION (SHEETS 9 TO 15/ <br /> <br />All storm sewer and ponding cofistructed shall be within drainage & utility <br />easements. <br /> <br /> Civil O' Municipal <br /> Engineeri/~g 25 <br />Page 1 of 3 <br />~Ha01~Shared DocstMunJcJpaI~MSE~160~R~60F2ND ADD.R~I.doc <br /> <br />-141- <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.