Laserfiche WebLink
Review Letter: Sunfish Gateway <br />February 1, 2001 <br />Page 2 of 3 <br /> <br />Setbacks: The building location exceeds the required setbacks for the Industrial Zoning District. <br />City Code also requires a 20-foot green space area adjacent to all public roads. This standard is <br />being met. <br /> <br />Screening: The abutting properties to the north, south, east and west are zoned for Industrial <br />and Business and City Code does not require screening in these areas. <br /> <br />Landscaping: The Landscaping plan dated January 10, 2001 is generally acceptable provided <br />that. Norway Maples (in the Item "A" table) are not used. Staff would also.recommend that spirea <br />and potentilla (in the Item "E" table) be minimized due to their general over use. The applicant <br />should be commended for integrating the existing oaks into the site plan. Staff'Mll be available to <br />work with the grading contractor to ensure the best possible success on the project. <br /> <br />Architectural Standards: City Code restricts building height to 35 feet. The proposed building <br />will be 28 feet in height, which meets City standards. City Code restricts exterior wall finishes to <br />natural or prefabricated brick or stone or pre-cast concrete panels or some other material <br />approved by City Council. The exterior building materials for the building are proposed to consist <br />of rock/ace concrete block, brick, and glass, which meets the architectural standards established in <br />the Industrial District. <br /> <br />Waste Storage: City Code requires that all solid waste and refuse receptacles shall be stored <br />within a completely screened structure or container. The site plan does not identify areas for <br />outside storage of solid waste and refuse. If any are planned, they shall comply with City <br />Ordinances. <br /> <br />Off-Street Parking - Design: In accordance with City Code, all driveways, off-street parking <br />and maneuvering areas are proposed to be surfaced with concrete and finished with B-6/12 <br />concrete curbing. <br /> <br />Off-Street Parking - Spaces Required: City Code requires one (1) parking space for every 200 <br />square feet of office space. For warehouse space in multi-tenant, the City uses the standard of <br />one parking stall per 1,000 square feet. The site plan shows 145 parking stalls with the possibility <br />of 14 additional spaces which exceeds the City requirement of 112 spaces needed for this <br />development. <br /> <br />CSAH 57 Access - Anoka County has indicated that no access should be allowed from this <br />development on to CSAH 57. However, if access is granted, the County states that the access <br />should be moved north to align with Sunfish Lake Court. You have indicated that the access is <br />necessary for the development. Given your feelings on this matter and the future development <br />potential for the rest of the parcel, staff and yourself should meet to discuss the overall traffic <br />circulation plan for the development. <br /> <br />Lighting: The site plan is absent a lighting plan. A lighting plan will need to be submitted and is <br />subject to the City Engineers approval. <br /> <br />-185- <br /> <br /> <br />