My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 08/12/2003
Ramsey
>
Public
>
Agendas
>
Council
>
2003
>
Agenda - Council - 08/12/2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:52:30 PM
Creation date
9/5/2003 12:48:21 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
08/12/2003
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
461
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Hakanson <br />Anderson <br />Assoc.,Inc. <br /> <br />MEMORANDUM <br /> <br />To: Brian Olson, Assistant Public Works Director/Principal City Engineer <br /> <br />From: Peter R. Raatikka, PE <br /> <br />Date: August 7, 2003 <br /> <br />RE: Ramsey Town Center <br /> <br />i <br />I <br />I <br />I <br /> <br />I <br />I <br /> <br />-304- <br /> <br />As requested, we have reviewed the latest preliminary plat submittal for the Ramsey Town <br />Center Development. Following is a list of our comments and corrections that need to be made: <br /> <br />1. The street alignments to the north of Bunker Lake Boulevard are shown differently on the <br /> grading plan than the other submittal documents. <br /> <br />2. In review of the Table of the Elevation Summary dated July 25, 2003, the building <br /> elevations for all buildings should be shown, both on the table and on the grading plan. <br /> <br />3. In review of street plans, the vertical curve elevation data on sheets 39 and 45 was not <br /> legible. <br /> <br />4. In review o£the utility plans, there are several conflicts with the storm sewer and the <br /> watermain. These conflicts will need to be corrected on the final plans. <br /> <br />5. On sheet 81, the pipe size is missing on Zeolite Street. On Sheet 83, the inverts for the <br /> 30" and 48" flared end sections are missing. <br /> <br />6. On sheets 77, 80 and 82, several of the storm sewer and watermain pipes are missing. <br /> <br />7. In review of the grading plan, the road construction entrances and street access points <br /> along Bunker Lake Boulevard should be eliminated where access is not allowed. <br /> <br />8. On sheet 81, revise the building layout to accommodate Southwest Pond shown on Sheet <br /> 18 of the Grading Plan. <br /> <br />Pond D3 -NWL shown on Sheet 17 indicates an elevation of 863.7. Outlet pipe shown <br />on Sheet 80 shows an outlet elevation of 866.0. Also, a 36" pipe was modeled as the <br />outlet, but a 30" is shown on Sheet 80. <br /> <br />G:\ComDev~PROJECTS\Landuse\SUBDIVNZ\Town Center~hakanson comments 8.7.03.doc <br /> <br /> I <br /> I <br /> I <br /> I <br />I <br /> I <br />I <br />I <br />! <br /> I <br /> I <br /> I <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.