Laserfiche WebLink
Sheet 65 <br /> <br />Sheet 66 <br /> <br />Sheet 70 <br /> <br />Sheet 71 <br /> <br /> 1. <br /> <br />Sheet 74 <br /> <br />Sheet 76 <br /> <br />Sheet 81 <br /> <br />Sheet 83 <br /> <br />Pipe from MH '802A to CBMH 708 is shown as a 33" on the plans, but is modeled and shown <br />in the pipe sizing worksheet as a 36". <br /> <br />Pipe form CBMH 708 to MH 801 is shown as a 42" on the plans, but is modeled and shown <br />in the pipe sizing worksheet as a 36". <br /> <br />MH 801 is labeled MH 802A in the profile. <br /> <br />Pipe from CBMH 326 to CBMH 327 is shown as a 21" on the plans. It is shown as a 15" in <br />the pipe sizing worksheet and it is also upstream of a 15". <br /> <br />Pipe from CBMH 215 to CBMH 217 is shown as a 15" on the plans, but is modeled and <br />shown in the pipe sizing worksheet as an 18". <br /> <br /> ?~ 18" <br />Pipe from CBMH 214 to CBMH _1.~ is shown as an on the plans, but is modeled and <br />shown in the pipe sizing worksheet as a 24". <br /> <br />Pipe from CBMH 213 to MH 201 is shown as a 21" on the plans, but is modeled and shown <br />in the pipe sizing worksheet as a 24" <br /> <br />Structure nUmbers CBMH' 19A and CBMH 19B are used twice, please clarify. <br /> <br />CBMH 233 in the plan view should be CB 206. <br /> <br />CBMH 10 in the plan view should be CBMH 8. <br /> <br />According to the existing contours, a culvert will be needed under West Ramsey Parkway on <br />the east side of Armstrong Blvd. <br /> <br />G:\Municipal\Aramsey\95 I\ra951 I~EVIEW.doc <br /> <br />Page 8 <br /> <br />Hakanson <br />Anderson <br />Assoc., Inc. <br /> <br /> <br />