City of Ramsey <br /> 15153 i~IOWTHEN BOULEVARD N.W., RAMSEY, <br /> <br />MINNESOTA 55303 <br /> <br />PHONE (612) 427-1410 FAX (612) 427-5543 <br /> TTD (612) 427-8591 <br /> <br />April 28, 1995 <br /> <br />Marly Glines <br />Phoenix Enterprisea <br />241 Main Street, Sflite 4 <br />Elk River, Mn 553B0 <br /> <br />Re: Site Plan R~iew; Trend Scientific <br /> <br />Dear Mr. Glines: <br /> <br />We are in receipt o~f a Site Plan consisting of (1) sheet dated April 25, 1995, prepared by Lampert <br />Architects. The pl '~[n proposes to construct a manufacturing facility on Lot 1, Block 1, Business <br />Park 95. We offer flae following comments: <br /> <br />Zoning: The site isizoned Industrial for which manufacturing is a permitted use. <br /> <br />Lot Coverage: The4 site is approximately 3.5 acres in size or 154,080 square feet. Lot coverage is <br />restricted to 35% o!' 53,928 square feet. The proposed size of the building is 24,960 square feet <br />for a lot coverage {~f 16%. The site plan also references a future building expansion of 17,960 <br />square feet. With ~e proposed future expansion, the lot coverage will total 42,920 which is still in <br />compliance with Cily Code. <br /> <br />Utilities: The facili~ will be served by municipal utilities. <br />Setbacks: The structure will front Uranium Street N.W. and the location exceeds the 40 foot front <br />yard, 20 foot side y~d and 35 foot rear yard setbacks. <br /> <br />Screening: No screi~ning is required as the site is surrounded by other Industrial properties. <br /> <br />Landscaping: In a~cordance with City Code, a landscape area is proposed adjacent to Uranium <br />Street N.W~- The~e is also landscaping proposed along the building fro'nt. Landscaping is <br />proposed to consist bf 12 trees and 46 shrubs. All plantings must be located 20 feet from the edge <br />of street pavement. !The plan also proposes to seed and mulch all disturbed areas. <br /> <br />Architectural Stan :~trds: City Code restricts building height to 35 feet and exterior wall finishes <br />must be of material lthat is 50% other than metal on the exposed walls. The site plan appears to be <br />for a 1-story buildit~g at 22 feet high, which is in compliance with City Code. However, there is <br />also reference on th{e site plan to a future second story that indicates a proposed building height of <br />55 feet which is notlin conformance with City Code. This issue needs to be resolved. The exterior <br />facing finish of the !walls is proposed to be pre-cast concrete panels which is in compliance with <br />City Code. <br /> <br />Wi~ste Storage: City Code requires that all solid waste and refuse receptacles shall be stored within <br />a completely screen~ structure or container. The site plan does not indicate a waste storage area in <br />accordance with Cit~ Code and the plan should be amended accordingly. <br /> <br />Off Street Parking ~ Desi~; In accordance with City Code, all driveways, off-street parking, <br />loading and maneuvering areas are proposed to be surfaced with bituminous and finished with B- <br />612 concrete curbing. <br /> ? <br /> <br /> <br />