Laserfiche WebLink
Pre -Demolition Survey <br />8020 — 147th Ave. NW, Bldgs. 1 & 2, Ramsey, MN <br />Page #4 <br />Summary of Hazardous Materials <br />Building 1 <br />Techtron Engineering Inc. <br />TEI Job #F12-2879 <br />September 4, 2012 <br />Limited hazardous materials were present in building 1 at the time of the survey. The <br />inspector noted roughly seven light ballast with possible PCB's and fourteen fluorescent <br />bulbs which contain mercury vapor. <br />Building 2 <br />Multiple hazardous materials were identified at building 2 at the time of the survey. <br />Approximately nine fluorescent bulbs and seven light ballast were found throughout the <br />building. Two mercury -containing thermostats were found in the building space. The <br />exterior A/C units will also need to be removed due to the units likely containing Freon. The <br />inspector noted five separate air conditioner units along the east side of the building. Lastly, <br />multiple electrical transformers, which commonly contain PCB's, were present in the <br />building near the other electrical equipment. <br />Flaking Paint throughout Property <br />All flaking /deteriorated paint on the subject property was tested using an XRF analyzer to <br />determine if paints were lead -based. None of the flaking/deteriorated paints tested on the <br />subject property met the EPA/HUD lead -based paint standard of 1.0mg/cm2. Database of <br />XRF sampling results can be found in appendix I. <br />*Although not considered hazardous materials, any major appliances that remained in the <br />buildings (i.e. water heater, garage door motors, furnaces) should be removed prior to <br />demolition. These materials cannot be disposed of as general construction debris. <br />