Laserfiche WebLink
of layers with different permeabilities that may cause sidehill <br />seepage. In no case shall a trench be located within fifteen (15) <br />feet of where such a layer surfaces on the downslope. <br /> <br /> 2. Bed construction shall be limited to areas having natural <br />slopes of less than six per cent (6%). <br /> <br /> 3. Any soil treatment area shall be set back the following <br />distances from the features given below. <br /> <br />Feature <br /> <br />Setback Distance in Feet <br /> <br />Water supply well less than <br />50 feet deep and not en- <br />countering at least 10 feet <br />of impervious material <br />Any other water supply well <br />or buried water suction <br />pipe <br /> <br />100, <br /> <br />50 <br /> <br />Buried pipe distributing <br />water under pressure <br /> <br />10 <br /> <br />Building 20 <br /> <br />Property lines <br /> <br />10 <br /> <br />*Required for new developments and, where applicable, for <br /> existing developments. <br /> <br /> 4. Any soil treatment area shall be set back the following <br />distances if located in an area which has been designated as <br />follows by any local, state or federal regulation. <br /> <br />Regulations <br /> <br />Setback Distance in Feet <br /> <br />Recreational development lakes <br /> <br />75* <br /> <br />General development lakes and <br /> streams <br /> <br />50* <br /> <br />Wild river 150, <br /> <br />Scenic river <br /> <br />100, <br /> <br />Critical river <br /> <br />100, <br /> <br />Designated tributaries of wild, <br /> scenic and recreational <br /> rivers <br /> <br />75* <br /> <br />*Required for new developments and, where applicable, for existing <br />developments. <br /> <br /> <br />