09900 PAINTING (S) — Includes exterior cement board and exposed unfinished metals, interior gypsum
<br />board, hollow metal doors and frames, coiling steel doors, staining and sealing interior and exterior
<br />woodwork
<br />10000 TOILET PARTITIONS AND ACCESSORIES (M) — Includes toilet and urinal partitions, toilet
<br />accessories, janitors room accessories, fire extinguishers and cabinets, interior room signs.
<br />11400 FOOD SERVICE EQUIPMENT (S) — Includes 2 each stainless steel custom counters at Concessions
<br />coiling doors, three compartment sink with faucets, traps and drains, and $3000 allowance for tables
<br />and shelving.
<br />15400 PLUMBING (S) — Includes connection to sanitary sewer at building line, connection to water in
<br />Mechanical Room, purchase water meter from City, connection to gas at meter (meter by others),
<br />plumbing, water, waste, vent and gas piping, plumbing fixtures and equipment, grease trap, pipe
<br />insulation, water heater and tempering valves, hose bibs.
<br />15800 HAVC (S) — Includes heating, air conditioning and ventilating equipment, ductwork, duct
<br />insulation, louvers, grilles and registers, exhaust piping and exterior trim, manual control dampers,
<br />thermostat, venting water heater, copper condensate lines.
<br />16000 ELECTRICAL (S) — Includes temporary electric service and connection to jobsite trailer,
<br />underground electric from transformer to building, meter socket, CT cabinet, service panel, time clock,
<br />occupancy sensors, photo cell, interior and exterior lights, switches, outlets, pipe and wire, grounding,
<br />power for HVAC and Plumbing, rough in security and power at exterior doors, and building telephone.
<br />Plumbing Specifications:
<br />This is a "Design — Build" plumbing contract. The work includes all necessary plumbing drawings, riser
<br />diagrams and other design information and certification required by the Department of Labor and
<br />Industry to obtain a building permit. All code required plumbing construction whether listed below or
<br />not is to be included in the plumbing bid. The cost of DOLI review is to be included, as well as City of
<br />Ramsey plumbing permit fees. The minimum Owner requirements are as follows:
<br />All supply, waste and vent piping, cleanouts, traps, ball valves only, hammer arresters, hangers, and
<br />brackets.
<br />2 each ADA wall hung toilets with manual flush valves.
<br />2 each wall hung toilets with manual flush valves.
<br />1 each ADA wall hung urinal with carrier and manual flush valve.
<br />1 each ADA wall hung urinal with carrier and manual flush valve.
<br />
|