Laserfiche WebLink
CITY OF RAMSEY LAND USE APPLICATION <br />TECHNICAL REVIEW FILE <br /> <br />D NPA <br /> <br />ATEOVEMBER ROJECT DDRESS ALPINE DRIVE AND HELIUM <br />24,2014 <br /> STREET <br />P. F.2 <br />ROJECT TITLEIRE STATION NO PRELIMINARY PLAN REVIEW <br />E# <br />SCROW <br />D: Engineering <br />EPARTMENT <br />Name: Leonard Linton <br />TR: <br />Phone: 763 433-9834 <br />ECHNICAL EVIEWER <br />Email: llinton@ci.ramsey.mn.us <br /> <br />We offer the following comments regarding updated plans dated November 17, 2014 prepared by <br />Wenck in association with BKV Group. <br /> <br />Staff offers the following comments: <br /> <br />Sheet Certificate of Survey <br /> <br /> <br />1. <br /> <br />2.City Code requires extending the survey to 100 feet beyond the property lines on all sides <br />of the project. <br /> <br />Sheet C102 <br /> <br /> <br />1.Install signs indicating trail and sidewalk will be closed. <br /> <br />2. <br /> <br />3. <br /> <br />4. <br />foot from face of curb. Mill existing wear course 1 foot wide prior to replacing pavement <br />so that vertical joints are offset. <br /> <br />5.Remove sidewalk with curb removal for new driveways. <br /> <br />Sheet C103 <br /> <br /> <br />1.Coordinate fence removal, construction of retaining wall and new fence to maintain <br /> <br />security of tower site. <br /> <br />Sheet C201 <br /> <br /> <br /> <br />1. <br /> <br />shall be Class 53. <br /> <br />2. <br /> <br />3.Change 9xx.xx to 8xx.xx for CBMH 3. <br /> <br />4.Label storm sewer pipes with length, size, and slope. Label storm sewer structures with <br /> <br />rim elevation, invert elevation and structure size. <br /> <br />