My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/08/2004
Ramsey
>
Public
>
Agendas
>
Council
>
2004
>
Agenda - Council - 06/08/2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:27:06 PM
Creation date
6/4/2004 2:54:38 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/08/2004
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Final Nat Rcvicx.x: <br />June 4.2004. <br />Page 3 {)1'5 <br /> <br />Rivenwick Vi li a,ge <br /> <br />turn hmo Ii'om ca~.;t bound I'[ l I0 to Riverdale drive must be shown in the plans. No certificate of <br />occupancies will be issued for Lol~ 1, 2.. 3, 4, Block 1 until the upgrade of Highway 10 has been <br />completed and accepted by thc Cit.~, arid MnDot. <br /> <br />Final Grading aud Drainag. e Plan: 'l'he grading and drainage plans are in general conformance <br />to city requirements; however the tbllowing items must be addressed before the plans are <br />approved. Enginc,..~red plans for the retaining walls around the pond must be provided. <br /> <br />Sound Mitigation: An eight (8) I'bot high berth has been provided between the buildings and TH <br />10. The City Co,mcil will bo di:;cnssing if the proposed berm will satisfy sound mitigation <br />requirements. <br /> <br />Constructinn Plans and Specifications: The construction plans for the utilities are in general <br />conformance to city standards. We do have some additions as noted below: <br /> <br />Ramsc5 public works prel!crs to have the watermain' valves spaced so that no more <br />than 10-15 customers ar,: with out water if a section of wate~ain must be shut down. <br />Please add gate valves it thc following locations: <br /> o 13~? Avenue midw:~y between Driveway B and Driveway C <br /> o 13~;~h Avenue east o i'Driveway E <br /> o Gr~:cnspace bctweett Driveway F and Driveway I. <br /> o 138th Avenue east of l)riveway H <br /> East leg ol"3asper Street and Driveway K <br /> o East leg of Jasper S~reet and Ddve~vay L <br /> o South and west Iegs at intersection of Driveways K & L <br /> North leg ofintcrse{ tion of Driveways K & M <br /> <br />All 6" ductile iron pipe :mist be class 53. <br /> <br />Usc at }~ydrant extensio~ (up to 2 feet) instead of tipping the Tee and installing a 45° <br />vertical bend on the hyd:am leads. Maximum hydrant extension shall be 3 feet. <br /> <br />Verify the water service requirements for the Heritage Condominiums. One 2" water <br />service tbr the entire building seems rather small. <br /> <br />TI~c City of Ramscy is adopting a building sprinkler ordinance. All buildings over <br />8500 .% l't gross will require, a sprinkler system. The ordinance will be effective July <br />2004. I valuate/his corn ment with the previous comment. <br /> <br />Thc ¢vl.4uhole ami Catc',~ Basin details do not show the watertight wrap around the <br />rings. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.