Laserfiche WebLink
CN? Storage: Site Plan Review <br />June 25, 2004 <br />Page 4 of $ <br /> <br />Ground Cover: Ail landscaped areas must be sodded and irrigated per City Code. The <br />landscaping plan should be revised to inciude this information. <br /> <br />Architectural Standards: City Code restricts building height to 65 feet and exteridr wall <br />finishes to natural or prefabricated brick or stone or pre-cast concrete panels or some other <br />material approved by City Council; Building elevations have yet to be submitted; these must be <br />shown at the Planning Commission meeting. <br /> <br />Waste Storage: City, Code requires that all solid waste and refuse receptacles be stored within a <br />completely screened structure or Container. The submitted site plan does not show a waste <br />storage area; please indicate on the revised site plan where this will be located. <br /> <br />Off-Street Parking - Spaces Required: City Code does not establish a minimum number of <br />parking spaces for mini-storage facilities, and nO park/~ng spaces are shown 0n the. submitted site <br />plan. PLease indicate on the revised plans if off-street parking wilt be provided on the site. <br /> <br />Off Street Parking - Design: In accordance with City, Code, all parking and maneuvering areas <br />must be surfaced with bituminous and the perimeter of all-pavement Mil be finished with B6/12 <br />concrete curbing. <br /> <br />Lighting: The submitted site plan does not include any information on lighting for the proposed <br />project. Please include this information on the revised site plan. City industrial lighting standards <br />require that the luminaire (light source) must not be visible from beyond the property line. Light <br />fixture drawings and specs must be submitted to the City fbr review and approval. <br /> <br />Drainage and Grading: A drainage and grading plan has been prepared as sheet 5 of 5 of the <br />submittals dated April 29, 2004. This plan proposes to collect drainage from the northern two <br />units through a series, of storm sewer pipes and discharge runoff into an existing storm water <br />ponding area located in the adjacent Regency Ponds subdivision. Runoff from the southern unit <br />discharges into a depression located on the property to the west. <br /> <br />The grading and drainage plan. should be revised to show concrete curb and gutter surrounding <br />all paved are~. Consequently the southern unit wilt need [o be served by an extension of the <br />internal storm sewer system. Calculations must be prepared showing the impact of the proposed <br />storm water discharge on the existing pond in the Regency Pond subdivision. A hydrograph of <br />the pre and post development conditions must be presented for the 10 year and 100 year events <br />along with identification of the peak water elevations caused by both these events. Consideration <br />should be given to increasing the volume of this pond by utilizing the eastern 50 feet of the <br />subject property. A permit will be required by the. Lower Rum River Water Management <br />Organization <br /> <br />44 <br /> <br /> <br />