adjoining lots on both sides of a proposed building site, structure setbacks may be altered without <br />a variance to conform to the adjoining setbacks from the ordinary high water level, provided the <br />proposed building site is not located in a shore impact zone or in a bluff impact zone. Structures <br />shall be located as follows. <br /> <br />1. Structure and On-site Sewage System Setbacks (in feet) from Ordinary High <br />Water Level*. <br /> <br /> Setbacks* <br />Classes of <br />Public Structures Sewage Treatment <br />Waters Unsewered Sewered System <br /> <br />Lakes <br /> <br />Natural <br />Environment 150 150 150 <br />Recreational <br />Development 100 75 75 <br />General <br />Development 75 50 50 <br /> <br />Rivers <br /> <br />Remote 200 200 150 <br />Forested and <br />Transition 150 150 100 <br />Agriculture, <br />Urban, and <br />Tributary 100 50 75 <br /> <br />*One water-oriented accessory structure designed in accordance with Section 9.25.05, Subd. 6.b <br />of this section may be set back a minimum distance of ten (10) feet from the ordinary high water <br />level. <br /> <br />2. Additional Structure Setbacks. The following additional structure setbacks apply, <br />regardless of the classification of the waterbody: <br /> <br />Setback From: <br /> <br />Setback (in feet) <br /> <br />(1) top of bluff; 30 <br /> <br />(2) unplatted cemetery; <br /> <br />50 <br /> <br />(3) right-otCway line of 50 <br /> federal, state, or <br /> <br />13 <br /> <br /> <br />