Laserfiche WebLink
Town Center 3rd Addition - Site Plan/Corner Retail" <br />July 8, 2004 <br />Page 2 of 6 <br />buildings (19,000 sq. ft) is 93,207 square feet. This is a 102,499 square foot deficiency in the <br />minimum floor area ratio requirement for Lot 1, but to be expected when one of the structures <br />(grocery store) is a large scale user that requires a significant amount of surface parking. Some <br />alternatives to resolve the issue of minimum floor area ratios for this block are as follows: a) <br />apply fbr a variance to the floor area ratio requirement;, b) amend the TC-2 district regulations to <br />lower the floor area ratio requirement; c) redesign the plat to create a lot for each building and <br />plat the excess area as common area for overflow parking in order to meet the floor area ratio <br />requirement. <br /> <br />Setbacks: The proposed Town Center Zoning District has setback standards based on the <br />principle of "build to" lines rather than traditional setbacks. This is especially important for the <br />front yard since it is typically where the building presentation relationship is to the street. The <br />setbacks in the TC-2 District have been established as follows: Front; 0-15 feet, Side: 10 foot <br />setback from building to building, 0 foot setback from building to property line, Rear 30 feet. 2 <br />is apparent that the proposed corner retail building meets the front, side and rear setbacks and the <br />setbacks distances should be called out on the site plan. However, Section 9.11.01, Subd. 7 of <br />City Code requires a vision clearance triangle at comer intersections to provide adequate sight <br />distance. The placement and design of the comer retail building will have to allow for a clear <br />vision triangle fbrmed by creating a third leg which connects the ends of two 25 foot legs, as <br />measured from the face of curb on the cross street being approached. This vision triangle must <br />be three dimensional and shall extend from 30 inches to 9 feet above the top of curb. This vision <br />triangle shall contain no fence, structure, earth bank hedge, planting, wall or other sight <br />obstruction. <br /> <br />Grading and Drainage Plan: We will reiterate the comments offered in the site plan review <br />letter for the grocery store <br /> <br />· The minimum allowable slope on bituminous surfaces must be 1.0%. The minimum <br /> slope on concrete surfaces is 0.5% <br />· Spot elevations should specify top or bottom of curb, <br />· Maximum cross slope in drive aisles should be 2.0% <br />· The pond elevations on Page 9 do not match the information shown on the other <br /> sheets. <br />· The retaining wall around the plan is called out as combined retaining wall and <br /> building fboting. Signed engineering drawings will be need to be submitted to the <br /> building inspection department for review prior to approval of this concept. <br />· Grade transitions should be smoothed out, the current plans show grade changes of <br /> 2%+ on different sides of contour lines. <br /> <br />Utility, Plan: We generally reiterate the comments offered in the site plan review letter for the <br />grocery store: <br /> <br />· The hydrant in front of the large retail building on page 9 conflicts with the storm <br /> water lead to the build and is too close to the catch basin. Move the hydrant to a <br /> cii:/"ferent island. The landscaping plan shows a tree in the same location as this <br /> hydrant. Additional coordination of the plans is necessary. <br /> <br /> <br />