My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 08/10/2004
Ramsey
>
Public
>
Agendas
>
Council
>
2004
>
Agenda - Council - 08/10/2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:29:58 PM
Creation date
8/9/2004 7:46:28 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
08/10/2004
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(g) the appearance of open space areas, including topography, vegetation, and <br />allowable uses, must be preserved by use of restrictive deed covenants, permanent <br />easements, public dedication and acceptance, or other equally effective and permanent <br />means; and <br /> <br />(h) the shore impact zone, based on normal s~ructure setbacks, must be included as <br />open space. For residential PUD's, at least 50 percent of the shore impact zone .area of <br />existing developments or at least 70 percent of the shore impact zone area of new <br />developments must be preserved in its natural or existing state. For commercial PUD's, <br />at least 50 percent of the shore impact zone must be preserved in its natural state. <br /> <br />3. Erosion Control and Stormwater Management. <br />management plans must be developed and the PUD must: <br /> <br />Erosion control and stormwater <br /> <br />(a) be designed, and the construction managed, to minimize the likelihood of serious' <br />erosion occurring either during or after construction. This must be accomplished by <br />limiting the amount and length of time of bare ground exposure. Temporary ground <br />covers, sediment entrapment facilities, vegetated buffer strips, or other appropriate <br />techniques must be used to minimize erosion impacts on surface water features. Erosion <br />control plans approved by a soil and water conservation district may be required if project <br />size and site physical characteristics warrant; and <br /> <br />(b) be designed and constructed to effectively manage reasonably expected quantities <br />and qualities of stormwater runoff. Impervious surface coverage within any tier must not <br />exceed 25 percent of the tier area, except that for commercial PUD's 35 percent <br />imper,~ious surface coverage may be allowed in the first tier of general .development <br />lakes with an approved stormwater management plan and consistency with this section. <br /> <br />4. Centralization and Design of Facilities. Centralization and design of facilities and <br />structm:es must be done according to the following standards: <br /> <br />(a) plmmed unit developments must be connected to publicly owned water supply <br />and sewer systems, if available. On-site water supply and sewage treatment sy.stems <br />must be centralized and designed and installed to meet or exceed applicable standards or <br />rules of the Mirmesota Department of Health and this section. On-site sewage treatment <br />systems must be located on the most suitable areas of the development, and sufficient <br />lawn area free of limiting factors must be provided for a replacement soil treatment <br />system for each sewage system; <br /> <br />(b) dwelling units or sites must be clustered into one or more groups and located on <br />suitable areas of the development. They must be designed and located to meet or exceed <br />the following dimensional standards for the relevant shoreland classification: setback <br />from the ordinary high water level, elevation above the surface water features, and <br />maximum height. Setbacks from the ordinary high water level must be increased in <br />accordance with this section for developments with density increases; <br /> <br />3t <br /> <br />-221- <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.