Laserfiche WebLink
4 <br />3 <br />1 <br />GENERAL NOTES <br />FOR CONSTRUCTION STAKING AND SURVEYING SERVICES CONTACT LANDFORM <br />PROFESSIONAL SERVICES AT 612.252.g070. <br />DEVELOPER <br />NATIONAL SELF -STORAGE, LLC <br />,1 <br />I / / 1 I --I <br />1 -t <br />® LANDFORM 2017 <br />NYLOPLAST CB #205 <br />RIM=875.0 <br />INV=873.18 <br />DIA=18" <br />BEEHIVE <br />CBMH #204 ( C7.3 <br />R1M=876.33 1 2 <br />INV=873.04 <br />DIA=48" <br />R-3067 <br />CBMH #203 <br />RIM=876.03 <br />INV=872.64 <br />DIA=2•x3' <br />R-3067 <br />C7.3 <br />2 <br />CBMH #202 C7.3 <br />RIM=875.53 2 <br />INV=871.88 <br />DIA=48" <br />R-3067 <br />CB <br />RE=873.2 <br />1 A \ 1 r- <br />1 /_\ I I- <br />L- / % 1 Y L_ <br />0 <br />A 1 1 A / <br />1\I 1/11 <br />1 Y r r <br />CB - <br />RE=873.2 <br />CB - <br />RE=872.1 <br />IE=86 1.1(E) <br />8=861.1(S) <br />IE=661.0(NW) <br />CBMH #301 <br />RIM=873.7 <br />INV=86g.66 <br />DIA=48" <br />R-3067 <br />C7.3 <br />2 <br />STMH #302 <br />RIM=874.0 <br />INV=870.25 <br />DIA=48" <br />R-3067 <br />C7.3 <br />CB <br />RE=873.8 <br />8=670.0(E) <br />IE=861.5(5) <br />IE=861.5(N) <br />CB -� <br />RE=575.3 <br />IE=861.1(5W) <br />IE=661.1(N) <br />CB -� <br />RE=575.2 <br />IE=861.1(E) <br />IE=870.1(5) <br />IE=871.3(W) <br />IE=861.1(NE) <br />16" RCP <br />1511 RCP <br />• <br />• <br />• <br />• <br />• <br />0 <br />36' 12 <br />w <br />15" RCP <br />,r. <br />r._ <br />KCP <br />• <br />18" RCP <br />4" SANITARY C7.2 <br />CLEAN -OUT <br />WITH WYE <br />INV=86q.82 SANITARY <br />SERVICE <br />INV=870.26 <br />/ <br />1 <br />26 <br />STORAGE BUILDING A <br />1-LEVEL <br />4,571 S.F. 20 <br />FFE =877.5 <br />35' 6" PVC @1.0% <br />INV=873.43 <br />RD <br />RD <br />• I <br />- -ELEC-�J► <br />'6 <br />4,1 <br />Pc <br />r <br />a <br />0 _, <br />RD <br />U <br />w <br />GAS 1-4 <br />C <br />TELE- ELE- ,--- <br />21 <br />11E=87 2.1 <br />=861.5(5) <br />1 (6 <br />E=87i3.0 <br />o=8611.5(N) <br />r861.4(W) <br />A <br />A <br />(6 <br />0 <br />c <br />I <br />60" « RCP 0.410 <br />--CE 1�I� <br />RE =874.0 I <br />: 871.5L\I\ .1 - _ <br />LOT I <br />4.45 4C <br />58' 6" PVC @ I.0% <br />INV=873.33 <br />C7.3 <br />RD <br />30' 6" PVC @ I.0% <br />INV=872.73 <br />STORAGE BUILDING B <br />3-LEVEL <br />26,280 S.F./LEVEL <br />FFE=877.5 <br />58' 6" PVC @1.0% <br />INV=872.75 <br />30' 6" PVC @ 1.0% <br />INV=872.35 <br />SANITARY <br />SERVICE <br />INV=870.6 <br />24 <br />26 <br />5 <br />2 <br />NYLOSPLAST CB #104 <br />RIM=875.0 <br />INV=873.08 <br />DIA=18" <br />BEEHIVE <br />g0d Bend <br />CONNECT TO <br />EXISTING <br />WATER <br />z <br />m <br />0 <br />OAS <br />I0 <br />to <br />I <br />I <br />15' <br />8" DIP <br />5" SDR 5 PVC' / .. -1- 1>1 <br />I / TA I Fi <br />A 1/ r- A so 1 r- <br />l_ ‘v L/ 1--_ I1 \r 11-- <br />/-1 I I\/ L_ <br />- 5511H <br />RC-8775 <br />IE=566.1(E) <br />IE=666.1(5 STUB) <br />CONNECT TO <br />EXISTING SANITARY <br />INV=866.g5 <br />C7.2 ) 4" SANITARY <br />8 J CLEAN -OUT <br />WITH WYE <br />INV=867.44 <br />\ ( C7.3 1 CBMH # 103 <br />l 2 J RIM=876.26 <br />INV=872.7 <br />DIA=48" <br />R-3067 <br />312D <br />u, <br />7, <br />LOADING <br />GARAGE <br />WAT SAN <br />°11012 4" PV( @ 2.0% <br />w <br />n) <br />73' 6", PVC @ 1.0% <br />)N�= <br />72;3 <br />Fl1Tl IRF <br />TORAGE BUILDING C <br />3-LEVEL <br />12,000 S.F. <br />CBMH # 10I C7.3 <br />RIM=876.35 2 <br />INV=87 1.75 <br />DIA=48" <br />R-3067 <br />CBMH #201 FUTURE STORAGE BUILDING D <br />RIM=875.33 1-LEVEL <br />INV=870.6g <br />DIA=48" 6,720 S.F. <br />R-3067 <br />C7.3 1 FES #200 <br />- J.LLV8Z0.5_ <br />C6 <br />RE=674.6 <br />IE=671.3(E) <br />IE=871.0(S) <br />IE=570.8(W) <br />62' 5IF RCP >@ 0 <br />r\ 1 11. 11 / <br />1-<1 1I\11.\ <br />\/ 1 r 1 \� <br />r\ <br />1 <br />C7.3 <br />6 <br />FUTURE TRAIL <br />OVERFLOW STRUCTURE <br />RIM=873.0 <br />INV=870.5 WATER PLUG <br />FUTURE <br />NEIGHBORHOOD <br />COMMERICAL <br />13,670 SF <br />LOT 2 <br />1.75 Ac. <br />18' RCP -- <br />IE=P171 (I <br />r� <br />1 A 1 , r- <br />I /\ K 1-- <br />L_ / \ 1 \ L_ <br />/ /\ ,. 1 I A 1 -1- \ / <br />OA , :/ Ii Ii i\v <br />15" RCP <br />✓ \ /\ 1 1 1 r- I/ A r\ r <br />I-< I II II I-- t/ /\ -e I V I <br />L J \, \, L_ L_ v / 1 <br />r\ /. A r- <br />re'. 1\, 1 / 1\ 1 I <br />1 1 LJ <br />,1 A .- <br />I I Y\ I <br />1 1 ., J <br />8 <br />j <br />A 1 1 A l <br />I\I 1/1/- <br />1 r VT 1.51 <br />70 A <br />1 <br />z <br />A <br />I° <br />2 <br />12 <br />1. 1 1 A / <br />1\1 Il1l <br />1 Y r r <br />3 <br />ADDITION <br />li _L <br />C7.2 \ COMMERCIAL <br />5 , WATER <br />SERVICE <br />C7.2 <br />3 <br />SANITARY <br />SERVICE <br />7 <br />C7.2 1HYDRANT AND GATE VALVE <br />5 <br />C7.3 1 CBMH # IO2 <br />2 J RIM=876.10 <br />INV=87 1.4 <br />DIA=48" <br />R-3067 <br />C7.2 1 SAN NH # I <br />I J RIM=874.5 <br />z <br />N <br />INV=868.4 6 <br />2 <br />C7.3 1 FES # 100 <br />3 J INV=870.5 <br />POND <br />NWL=870.5 <br />HWL=872.93 <br />z <br />SAN PLUG <br />FG=874.0 <br />INV=86q.3 <br />FUTURE <br />SOUTH <br />ACCESS <br />CB <br />RE=677.0 <br />IE=573.4(5) <br />IE=673.KW) <br />• <br />5 <br />4 <br />3 <br />2 <br />1 • 1 <br />LJ.J <br />1 • 1 <br />LJ.J <br />Ll_ <br />- <br />1 <br />/ ,\ <br />1 • 1 <br />LJ.J <br />I _ <br />8 <br />4 <br />I- <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />14 <br />1 <br />UTILITY NOTES <br />2. PIPE MATERIALS <br />WATERMAIN <br />WATER SERVICE <br />SANITARY SEWER <br />SAN. SEWER SERVICE <br />STORM SEWER <br />6-8" DIP CLASS 52 <br />I" COPPER TYPE K (ASTM B88) (BUILDING A) <br />6" FIRE SERVICE (BUILDING B) <br />PVC SDR 35 <br />PVC SDR 35, SDR 26, SCHEDULE 40 <br />RCP 12"-18" CLASS 5 (ASTM C76) <br />PVC 12-15" <br />3. CONTACT UTILITY SERVICE PROVIDERS FOR FIELD LOCATION OF SERVICES 72 HOURS <br />PRIOR TO BEGINNING. <br />4. CONTRACTOR TO FIELD VERIFY LOCATION AND ELEVATION OF ALL UTILITY POINTS OF <br />CONNECTION PRIOR TO CONSTRUCTION OF ANY PROPOSED UTILITIES. CONTRACTOR TO <br />NOTIFY ENGINEER IMMEDIATELY IF- THERE IS ANY DISCREPANCY. <br />5. CONTRACTOR TO POTHOLE ALL UTILITY CROSSINGS PRIOR TO CONSTRUCTION OF NEW <br />UTILITIES TO VERIFY DEPTHS OF EXISTING LINES. CONTACT ENGINEER IMMEDIATELY IF ANY <br />CONFLICTS ARE DISCOVERED. <br />6. PROVIDE MEANS AND MEASURES TO PROTECT ADJACENT PROPERTY FROM DAMAGE <br />DURING UTILITY INSTALLATION. <br />7. PIPE LENGTHS SHOWN ARE FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE <br />OR END OF END SECTION, <br />8. INSTALL TRACER WIRE WITH ALL NON-CONDUCTIVE UTILITIES. <br />g. CONNECT TO CITY UTILITIES IN ACCORDANCE WITH CITY OF RAMSEY STANDARDS. <br />10. CONTACT CITY OF RAMSEY PUBLIC WORKS FOR WET TAP INSPECTION. <br />II. MAINTAIN 7.5 FEET OF COVER ON WATER. <br />12. DEFLECT WATER TO MAINTAIN 18-INCH MINIMUM OUTSIDE SEPARATION AT SEWER <br />CROSSINGS. CENTER PIPE LENGTHS TO PROVIDE GREATEST SEPARATION BETWEEN <br />JOINTS. <br />13. CONTACT GRANT RIEMER, CITY OF RAMSEY PUBLIC WORKS DEPARTMENT, AT <br />763-433-g863 FOR FLUSHING AND PRESSURE TEST INSPECTIONS. <br />14. THE WATER DISTRIBUTION SYSTEM SHALL BE DISINFECTED PER MINNESOTA RULES, PART <br />4715.2250. <br />15. PROVIDE 4-INCH RIGID FOAM (ASTM D 1621) INSULATION ON SANITARY SEWER LESS THAN <br />8 FEET DEEP. SEE PETAIL C7.2/4 <br />16. ALL PORTIONS OF THE STORM SEWER SYSTEM, LOCATED WITHIN 10 FEET OF THE <br />BUILDING OR WATER SERVICE LINE MUST BE TESTED IN ACCORDANCE WITH MINNESOTA <br />RULES, PART 4715.2820. <br />17. ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR <br />WATER TIGHT. APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE <br />WATERTIGHT CONNECTIONS TO MANHOLES, CATCH BASINS, AND OTHER STRUCTURES. <br />18. CATCH BASINS IN CURB AND GUTTER ARE SIPPED 2 INCHES BELOW THE GUTTER <br />GRADE. REFER TO PETAIL 8 ON SHEET C7.2. <br />Ig. EXTEND INSULATION 4' BEYOND PLUG <br />20. COORDINATE WITH PRIVATE UTILITIES TO PROVIDE ELECTRIC, NATURAL SAS, AND <br />COMMUNICATIONS SERVICES TO BUILDING. <br />21. THE PRIMARY ELECTRIC FEED, TRANSFORMER, AND METER ARE PROVIDED AND INSTALLED <br />BY CONEXUS ENERGY. THE TRANSFORMER PAD DESIGN IS PROVIDED BY THE UTILITY <br />AND CONSTRUCTION IS BY THE CONTRACTOR. CONTACT UTILITY FOR PAD PETAIL. THE <br />SECONDARY ELECTRIC AND CONDUITS SHALL BE INSTALLED BY THE ELECTRICAL <br />CONTRACTOR. <br />22. SEE ELECTRICAL SITE PLAN FOR ADDITIONAL INFORMATION. <br />IDCENTER POINT WILL FURNISH AND INSTALL GAS SERVICE PIPING FROM THE MAINLINE TO <br />THE METER. GAS SERVICE FROM THE METER SHALL BE INSTALLED BY THE MECHANICAL <br />CONTRACTOR. <br />OORDINATE TELEPHONE WITH CENTURY LINK TO PROVIDE TELEPHONE SERVICE. <br />CONTRACTOR TO PROVIDE AND INSTALL A 4" PVC CONDUIT WITH PULL STRING, <br />SWEEPING BENDS ONLY (NO q0 DEGREE BENDS), FROM PROPERTY LINE TO THE BUILDING. <br />25. PROVIDE CONDUITS FOR CABLE TELEVISION AND OTHER ELECTRONIC COMMUNICATION. <br />26. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR LOCATIONS <br />OF SERVICE CONNECTIONS AND CONTINUATION OF SERVICES WITHIN BUILDING. <br />27. COMPACT COHESIVE SOILS IN PAVED AREAS TO g5% OF MAXIMUM DRY DENSITY, <br />STANDARD PROCTOR (ASTM D6g8) EXCEPT THE TOP 3 FEET WHICH SHALL BE <br />COMPACTED TO 100%. COMPACT TO g8% DENSITY WHERE FILL DEPTH EXCEEDS 10 <br />FEET. THE SOILS SHALL BE WITHIN 3% OF OPTIMUM MOISTURE CONTENT. IN GRANULAR <br />SOILS ALL PORTIONS OF THE EMBANKMENT SHALL BE COMPACTED TO NOT LESS THAN <br />g5% OF MODIFIED PROCTOR DENSITY (ASTM 01557). <br />28. ADJUST STRUCTURES TO FINAL GRADE WHERE DISTURBED. COMPLY WITH REQUIREMENTS <br />OF UTILITY. MEET REQUIREMENTS FOR TRAFFIC LOADING IN PAVED AREAS. <br />UTILITY CROSSINGS <br />O <br />r� <br />v <br />CROSSING I <br />SANITARY SEWER SERVICE TOP.=867.5 <br />WATERMAIN BOT=870.37 <br />CROSSING 2 <br />SANITARY SEWER SERVICE TOP.=868.4 <br />WATERMAIN BOT=870.37 <br />CROSSING 3 <br />STORM SEWER INV.=87 1.64 <br />SANITARY SERVICE TOP=86g.06 <br />WATER SERVICE TOP =86g.I <br />NORTH <br />Know what's Below. <br />Call before you dig. <br />0 50 100 <br />2827 107TH AVENUE <br />BLAINE, MN 55449 <br />MUNICIPALITY <br />PROJECT <br />REGENCY <br />COMMONS <br />RAMSEY, MN <br />SHEET INDEX <br />SHEET <br />TITLE <br />CO.1 CIVIL TITLE SHEET <br />C1.1 EXISTING CONDITIONS & DEMO <br />C2.1 SITE PLAN <br />C3.1 GRADING, DRAINAGE,& EROSION CONTROL <br />PAVING PLAN & NOTES <br />C3.2 SWPPP NOTES <br />C4.1 UTILITIES <br />C7.1 CIVIL CONSTRUCTION DETAILS <br />C7.2 CIVIL CONSTRUCTION DETAILS <br />C7.3 CIVIL CONSTRUCTION DETAILS <br />C7.4 CIVIL CONSTRUCTION DETAILS <br />C7.5 CIVIL CONSTRUCTION DETAILS <br />L1.1 TREE PRESERVATION PLAN <br />L 1.2 TREE PRESERVATION TABLE <br />L2.1 LANDSCAPE PLAN <br />L7.1 LANDSCAPE DETAILS <br />ISSUE / REVISION HISTORY <br />CONTACT ENGINEER FOR ANY PRIOR HISTORY <br />DATE <br />ISSUE / REVISION <br />REVIEW <br />03 JAN 2017 SITE PLAN SUBMITTAL <br />XXX <br />PROJECT MANAGER REVIEW <br />BY XX <br />DATE XX.XX.XXXX <br />CERTIFICATION <br />I hereby certify that this plan ma.' OIL, or under my direct <br />the laws of the state of I* <br />supervision, and that I am a rofessional Engineer under <br />0 0 IOC)* <br />Randall C. Hedlund 414* <br />_IL 011ic. <br />License No: 19576 10 e <br />Signature shown 15 <br />this plan on file <br />available upon r <br />uct,on of ortginal. Wet stared copy of <br />fess[onal Services, LLC office and is <br />IF THE SIGNATURE, SEAL OR FOUR LINES DIRECTLY ABOVE ARE NOT <br />VISIBLE, THIS SHEET HAS BEEN REPRODUCED BEYOND INTENDED <br />READABILITY AND IS NO LONGER A VALID DOCUMENT. PLEASE CONTACT <br />THE ENGINEER TO REQUEST ADDITIONAL DOCUMENTS. <br />SITE PLAN SUBMITTAL <br />01-03-2017 <br />• <br />• <br />A FORM <br />From Site to Finish <br />105 South Fifth Avenue <br />Suite 513 <br />Minneapolis, MN 55401 <br />Tel: 612-252-9070 <br />Fax: 612-252-9077 <br />Web: landfornn.net <br />FILE NAME <br />PROJECT NO. <br />NSS16001 <br />UTILIY PLAN <br />C4.1 <br />SHEET NO. 6/15 <br />Landformoand Site to Finish eare registered service marks of Landform Professional Services, LLC. <br />