Laserfiche WebLink
Geotechnical Tests: The boring profile consisted generally of topsoil overlying coarse alluvial soils <br /> and are suitable for development. The topsoil generally extended to between one-half and four feet(1- <br /> 4') below grade.The four(4) boring locations had a depth to groundwater which ranged between 9 to <br /> 10.5 feet. <br /> Utility Information: The site is currently served by public utilities. The following specifications may <br /> be adjustable depending on project demand. <br /> -Water: 12" watermain, adjacent (in Sunwood) [City of Ramsey, 763-433-9825] <br /> -Sewer: 30" line, adjacent(in Ramsey Blvd) [City of Ramsey 763-433-9825] <br /> -Gas: 6" line, 40-60 psi adjusted to meet requirements, adjacent(in Sunwood) [Centerpoint Energy, 763- <br /> 323-2685] <br /> -Fiber: Available (in Sunwood) [Comcast, 651-755-2602] [Century Link, 651-312-5387] [Zayo, 952-857- <br /> 9383] <br /> -Electricity: 12.5kV voltage available with up to 4 MW service [Connexus Energy, 763-785-5432] <br /> The COR development which this parcel is located within has a regional stormwater system which will <br /> allow for the site area to be maximized for development. <br />