Laserfiche WebLink
Automated EDM - Site Plan <br />October 8, 2004 <br />Page 2 of 3 <br /> <br />Ground Cover: All unimproved areas must, be sodded. Any alternative to sod will require City <br />Council's approval. Additionally, all landscaped areas are required to have an underground irrigation <br />system. <br /> <br />Architectural Standards: City Code restricts building height to 65 feet and exterior wall finishes to <br />natural or prefabricated brick or stone or pre-cast concrete panels or some other material approved by <br />City Council. [t appears that the site plan is proposing exterior building materials to consist of smooth <br />face and rock face concrete masonry block and building height will be no geater than 21 feet. <br /> <br />Waste Storage: City Code requires that all solid waste and refuse receptacles be stored within a <br />completely screened structure or container. Staff will assume that the addition will not relocate the <br />existing refuse containers. <br /> <br />Off-Street Parking - Spaces Required: City Code requires one parking space per 1,000 square feet of <br />warehouse floor space and one space for each 300 square feet of office space. The addition is required <br />to provide 11 parking stalls. As part of the first phase 30 parking stalls were installe4 and only 20 were <br />required. A total of 31 parking stalls are required to satisfy parking requirements for both phase one <br />and two. The site plan does not propose to install any additional parking stalls as part of the <br />construction of phase two. However, there is the ability to install an additional 19 ii' needed. The <br />existing 30 parking stalls and 19 proof of parking stalls will satisfy parking requirements. <br /> <br />Loading Docks: City Code requires one loading dock per 10,000 square feet of floor space. The site <br />plan is proposing to construct an additional 11,975 square feet of building space. It appears that an <br />additional two overhead loading areas are being provided, this exceeds City Code requirements. <br /> <br />Lighting: No exterior lighting appears to be proposed. If exterior lighting is being considered a <br />lighting plan must be submitted. <br /> <br />Drainage and Grading: The subject property and adjacent property currently drain to a common <br />pond, which occupies area on both properties. The grading plan proposes installing an outlet from this <br />common pond into the 30 inch storm sewer located on the north side on McKinley Street. This storm <br />sewer discharges into the regional pond located at the east terminus of McKinley Street. The elevation <br />of this outlet will limit the 100 year event to an elevation of 863.4 which is 2.1 feet higher than the <br />catch basin inlet on the neighboring.property's drive. This would cause water to pond briefly in a 100 <br />year event l~br a distance of 15 to 30 feet from the inlet. <br /> <br />The ponded area is not covered by a drainage and utility easement. The City Attorney has advised that <br />a drainage and utility easement wo.t. dd be required if additional ponding is caused because of the <br />increased amount of impervious area. Although an outlet will be provided which may improve the <br />current potemial for flooding to the adjacent property, the high water level from a 100 year event will <br />cause temporary flgoding o[ the adjacent property. Therefore as a condition of approval a drainage and <br />utility easement should be required ~om the adjacent property over that portion of their property which <br />would be inundated by a design storm event. <br /> <br /> <br />