W, Properr_ies - Site Plan <br />October_-~9. 2004 <br />Page '; <br /> <br />o~' pre-cast concrete pane~s. The highest point of the building will be approximatel.y 27 feet 6 inches in <br />height, which meets City Code requirements. <br /> <br />Waste Storage: City Code requires that. all solid waste and refuse receptacles be Stored within a <br />completely screened structure or container. The site plan shows a trash enclosure along the rear side of <br />the building, ellis meets City Code requirements. <br /> <br />Off-Street Parking - Spaces Required: City Code requires 'one parking space per 1,000 square ·feet of <br />warehouse floor space and one space for each 300 square feet of of'rice space. The site plan indicates <br />approximately [2,672 square feet will be.utilized' fbr office area and 29,568 square feet will-'serve as <br />warehouse area. Based on this inlbrmation, City code requires a total of 71' parking stalls and 73 .are <br />being provided. The site plan should be changed to indicate correct City Code requirements. <br /> <br />Bituminous Requirement: City Code requires all non turf areas to b4 paved with bituminous or <br />concrete and finished with B 6/12 concrete curbing. A portion of the rear parking lot is shown as Class <br />5. Class 5 is not a permitted material within the E-2 district and the site ¢[an should' be chanaed to <br /> <br />comt0b/with Cio/Code. it should als0 be noted that City Code does not permit storage of equipment or <br />.matet'ials on a Class 5 surface. <br /> <br />Loading l)ocks: City Code requires one loading dock for the first 10,000 square feet of floor space and <br />one loading dock for each additional 25,000 square feet of floor area. The site plan is proposing to <br />construct a 4_,,.~40 square foot building, therefore subject to at least 2 loading docks. The site plan is <br /> · ' - 4 loading docks and 8 overhead doors. <br />provt&ng <br /> <br />Lighting: The site plan submitted proposes no exter/or lighting. If exterior lighting is anticipated the <br />applicant is advised that stardards for commercial lighting have 'been established by the City of <br />Ramsey. <br /> <br />Drainage and Grading: A grading, drainage and erosion control plan has been prepared for this site <br />by Timothy Eggerichs PE. Drainage from the proposed building and parking areas are conveyed <br />overland and through a system of storm sewers to a regional treatment pond located on'the property <br />immediately south of the subject property. This plan is generally acceptable with the exception that the <br />proposed graveled surface must be replaced with hard surfaced paving. This will re,quire the <br />modification of the ,2radin_o plan aton~ the southern boundary of the site. in addition it should be noted <br />r. hat fa/ling must be provided alon_o the daylight walls located in front of the dockin,o bays. . <br /> <br />This p/an proposes to dis.turb mot'e that one acre of surface area and ~vill require a permit from the <br />Lower Runf River Water Management Organization. <br /> <br />REU: Th. is oror~e,,:tv will be subject to a storm water utility- charhe. The quarterly char=o will be <br />dependant upon the number of residential equivalent units (.~%EU). ·This Gctor will be determined once <br />~he ~:otal bt area and the net amount of impervious area have been submitted and revieweci. <br /> <br />21 <br /> <br /> <br />