My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/27/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 06/27/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:33:55 PM
Creation date
7/11/2017 8:03:38 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/27/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1054
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Splicing tracer wire shall be by mechanical split bolt type or a crimp type compression fitting fully <br />encased in approved electrical insulation putty. A twelve inch (12") tracer wire loop shall be <br />provided on each side of a spliced connection. <br />C Water Service Installations <br />Water service facilities consisting of Tap Service Lines and Branch Service Lines, complete with <br />all required appurtenances, shall be installed as required by in the Plans, Specifications, and <br />Special Provisions, in accordance with all pertinent requirements for main line installations <br />together with the provisions hereof. <br />It shall be the responsibility of the Contractor to keep an accurate record of the location, depth <br />and size of each service connection and other pertinent data such as the location of curb stops <br />and pipe endings. Tap locations shall be recorded in reference to survey line stationing. Curb <br />stops shall be tied to definable land marks such as building corners, lot corner markers, <br />hydrants, gate valves, etc. Pipe terminals at the property line shall be marked to the ground <br />surface with a suitable wood timber four by four inch (4"x4"), eight feet (8') long set vertically into <br />the ground with the top two feet (2') painted blue. Approved record keeping forms will be <br />furnished by the Engineer and the completed records shall be submitted by the Contractor upon <br />completion of the work. <br />Water service lines shall normally be installed by trenching and be subject to the same <br />requirements as prescribed for the main pipeline installation, except for those which may not be <br />pertinent or applicable. Where water service lines are installed alongside of sanitary service <br />lines, installation shall be such as to maintain the minimum specified clearances between <br />pipelines and provide proper and adequate bearing for all pipes and appurtenances. <br />Water service lines shall be installed to provide a minimum of six inches (6") of clearance shall <br />be maintained in crossing over or under other structures. Where the service pipe may be <br />exposed to freezing due to insufficient cover or exposure from other underground structures, the <br />water pipe shall be insulated as directed by the Engineer. <br />C1 Tee Branch Service Lines <br />Tee branch service piping shall be of the type, size, and wall thickness specified. The pipe and <br />appurtenances shall have rubber gasketed push -on or mechanical joints. Tee branch service <br />lines shall be provided as required by the Plans. <br />Installation of tee branch service facilities shall be in accordance with all applicable <br />requirements of these specifications as pertain to the mainline installations. <br />C2 Tapped Service Lines <br />Service piping shall be of the size and type specified. Unless otherwise specified, minimum pipe <br />size for tap service installations shall be one inch (1") nominal inside diameter. Larger size pipe <br />may be specified for commercial and industrial uses or for some domestic service as specifically <br />identified. <br />Installation of service facilities shall be in accordance with all applicable requirements of these <br />specifications as pertain to the mainline installations, subject to the exceptions and <br />supplementary provisions set forth hereinafter. <br />Page 32 <br />
The URL can be used to link to this page
Your browser does not support the video tag.