My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/27/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 06/27/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:33:55 PM
Creation date
7/11/2017 8:03:38 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/27/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1054
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIAL PROVISIONS - SP20I6 BOOK <br />Last Revision by CO Special Provisions: 2/08/17 <br />Created August 20, 2015 <br />Page 43 <br />SP 0202-101 <br />Table 2461-17 <br />Acceptance Criteria for Standard 28-day Cylinders <br />Single Strength Moving average of 3 consecutive strength tests * <br />tests <br />fc<5000psi >(fc-500psi) > f'c <br />fc > 5000 psi > 0.90 * f'c > fc <br />* If a project does not establish a moving average of 3 consecutive strength tests, use the average <br />of 2 strength tests to determine acceptance. If there is only a single strength test, contact the <br />Concrete Engineer for recommendation. <br />S-32.34 MnDOT 2461.3.G.5.f, 2461.3.G.5.f(1), 2461.3.G.5.f(2), 2461.3.G.5.f(3), and 2461.3.G.5.f(4) <br />shall be added: <br />G.5.f Non -Conforming Material <br />If the Contractor places concrete not meeting the strength requirements of 2461.3.G.5.e, "Concrete <br />Compressive Strength" into the work, the Engineer may not accept nonconforming concrete at the contract <br />unit price. The Engineer will evaluate non -conforming strength results in accordance with the following: <br />G.5.f(1) Single Strength Test < 500 psi Below Pc <br />If any single strength test (3 cylinders) shows a strength < 500 psi below fc and is not deficient <br />due to erroneous/invalid strength tests as defined in 2461.3.G.5.f(4), "Moving Average Below fc", no <br />additional investigation will occur and the Engineer will include the low strength test result in the moving <br />average. <br />G.5.f(2) Single Strength Test > 500 psi Below fc <br />If any single strength test (3 cylinders) shows a strength > 500 psi below f'c and is not deficient <br />due to erroneous/invalid strength tests as defined in 2461.3.G.5.f(4), "Moving Average Below fc", the <br />Engineer, in conjunction with the Concrete Engineer, will investigate to determine if the concrete has <br />attained the critical load -carrying capacity. <br />The investigation may consist of, but is not limited to reviewing the following: <br />(1) Sampling and testing plastic concrete <br />(2) Handling of cylinders <br />(3) Cylinder curing procedures <br />(4) Compressive strength testing procedures <br />(5) Certificate of Compliances <br />(6) Evaluation using Rebound Hammer (ASTM C803), Penetration Resistance (ASTM <br />C805), or other method approved by the Concrete Engineer <br />(7) Review of the design calculations for the concrete in question <br />If it is determined that the concrete represented by the single strength test has attained the critical <br />load carrying capacity, the Engineer will include the strength test in the moving average calculation. <br />If it is determined that the concrete has not attained the critical load carrying capacity, the <br />Engineer will direct the Contractor to remove and replace concrete in accordance with 1503, "Conformity <br />with Contract Documents," and 1512, "Unacceptable and Unauthorized Work." The Contractor may <br />dispute the remove and replace order within 7 days of written notification by the Engineer If the <br />Contractor disputes the order, follow the dispute resolution coring procedure in accordance with <br />2461.3.G.5.f(3), "Dispute Resolution Coring for Single Strength Test Failure." <br />G.5.f(3) Dispute Resolution Coring for Single Strength Test Failure <br />The Engineer and Contractor will mutually agree on an Independent Third Party to core and test <br />the concrete in accordance with ASTM C42. <br />
The URL can be used to link to this page
Your browser does not support the video tag.