My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 10/10/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 10/10/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:38:37 PM
Creation date
10/24/2017 2:20:09 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
10/10/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1081
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C.3.e. Miscellaneous <br />• 165-gallon tank (contents unknown) <br />• Air compressor <br />• Automotive parts <br />• Computer equipment <br />• Drive-thru system <br />• Meters <br />D. Discussion <br />D.1. Asbestos -Containing Materials <br />City of Ramsey <br />Project B1610732.00 <br />November 28, 2016 <br />Page 4 <br />Miscellaneous cleaning <br />supplies <br />• Stove/oven <br />• Television <br />• Water heater <br />• Water softener <br />D.1.a. Category I Non -Friable ACM <br />The following asbestos -containing materials are classified as Category I non -friable materials according to <br />EPA 40 CFR Part 61 National Emission Standard for Hazardous Air Pollutants (NESHAPs): <br />• Asphalt roof material (assumed), no roofing samples were collected to protect the integrity <br />of the roofing systems. <br />Note: The various roofing materials were noted at the time of this inspection. Roofing materials were not <br />sampled for asbestos content as part of this inspection in order to maintain the integrity of the roofing <br />system. The roofing materials should be sampled for asbestos content prior to building <br />renovation/demolition. <br />The above Category I non -friable ACMs were observed to be in good condition at the time of our <br />assessment. These materials should be maintained in good condition to prevent potential exposure to <br />asbestos. Category I non -friable ACMs are not considered a hazard unless cut, drilled, sanded, or <br />otherwise abraded. However, any Category I material that may become friable during demolition must <br />be removed prior to that activity. Secondly, if left in place, the crushing or recycling of demolition debris <br />is strictly prohibited. In addition, all demolition debris containing Category I materials must be disposed <br />of at a landfill specifically permitted to accept this type of waste. <br />D.2. Lead -Based Paint <br />No lead -based paint was identified on the surfaces tested during this inspection. In addition, given the <br />date of construction (2003) it is unlikely that lead -based paint is present. <br />D.3. Miscellaneous Regulated Waste <br />In the case of building renovation/demolition, any of the miscellaneous regulated waste items listed <br />in Section C.3 that will be disturbed, must be removed prior to disturbance and must be recycled or <br />disposed of in accordance with state and federal guidelines. <br />BRAUN <br />INTERTEC <br />
The URL can be used to link to this page
Your browser does not support the video tag.