Laserfiche WebLink
10/31/2017 09:12 AM <br />16 - Changemark #05 <br />Created by: Tim Gladhill <br />On: 10/10/2017 02:21 PM <br />Must share architectural renderings. <br />0 Replies <br />17 Changemark #06 <br />Created by: Tim Gladhill <br />On: 10/10/2017 02:23 PM <br />Eave overhangs should not be in easements. If this doesn't work, please discuss with City. <br />0 Replies <br />18 - Engineering Notes Preliminary Plat <br />Created by: Len Linton <br />On: 10/12/2017 08:47 AM <br />General: <br />The plans need a legend on every sheet showing every line type and symbol used on that sheet. <br />The scale and shape of the symbols in the legend must match the plan view. <br />The lines under text must be broken to make the text legible. <br />Use the City details available on the website. <br />Cover: <br />A location map is required. <br />A sheet index is required. <br />Removals Plan: <br />A removal sheet must be added to the set showing all items to be removed. The removed items <br />must not appear on the construction sheets. <br />Add sawcut lines for removing existing pavement. Identify quantity of bituminous to remove. <br />Removed items must not appear on any other sheet. <br />Grading Plan: <br />The minimum grade on all lots in all directions shall be 2.0% or greater. <br />Spot elevations are required at all lot corners. <br />Silt fence must be installed and inspected prior to any construction. <br />Silt fence must be installed up slope of the infiltration area after it is constructed. <br />Add tree protection fence to show limits of clearing. <br />Soil borings and a geotechnical report are required for borings in the proposed house locations <br />and the proposed streets. The number of borings shall be determined by the geotechnical <br />engineer to provide a recommendation for pavement design and lowest floor elevations. <br />Soil borings are also required in the proposed infiltration basins. The must extend to at least 6 <br />feet below the bottom of the proposed basins. These must be included in the geotechnical <br />report. <br />Borings and a report are also required in the proposed drainfield areas. <br />The boring reports must be submitted with the preliminary plat. <br />Minimum Floor Elevation is 2 feet above 100 year flood elevation or 3 feet above the highest <br />anticipated ground water level or 1 foot above the emergency overflow elevation. <br />Page 4 <br />