Review File: Cole Addition <br />Preliminary Plat <br />Engineering Review <br />June 28, 2017 <br />Page 2 of 3 <br />6. Show the existing sewer and water services from 168th Avenue. <br />C1.2: <br />1. A sheet specific legend is required listing all symbols and lines on this sheet. The legend <br />hatch does not match the plan view. <br />2. Show removal of existing driveway to nearest joint on lot 7. <br />3. Obtain access agreements for removing temporary cul-de-sac on private property. <br />4. Show removal of bituminous in 168th Avenue for construction of new services. Bituminous <br />must be sawcut and removed from curb to curb. <br />5. The notes refer to details that are not in the set, and sheets that are not in the set. <br />6. The intent of Notes 10 and 13 is not clear. <br />7. Note 14 does not have a symbol on the plan view. <br />C2.1: <br />1. A sheet specific legend is required listing all symbols and lines on this sheet. <br />2. Lot 3, Block 1 and Lot 3, Block 2 must be removed to provide room for a permanent cul- <br />de-sac. Staff has emphasized and the Planning Commission has supported elimination of <br />temporary cul-de-sacs during plan reviews for the last several years. If the adjacent <br />property develops in the future the City will consider vacating right of way so these lots <br />can be developed. <br />3. The radius of the ROW and cul-de-sac must be shown. <br />4. The drainage easement on Lot 2, Block 2 must be wider. <br />C3.1: <br />1. A sheet specific legend is required listing all symbols and lines on this sheet. <br />2. Soil borings are required in the infiltration areas and in the house pad areas to establish <br />groundwater elevations. <br />3. The lowest floor elevation must be at least 3 feet above the highest anticipated groundwater <br />elevation, 2 feet above the 100 year flood elevation <br />4. Refer to the attached guidance from Barr Engineering for determining the acceptable <br />lowest floor elevation. <br />5. The minimum grade on all lots in all directions shall be 2.0% or greater. <br />6. Show proposed elevations at all lot corners. <br />7. Silt fence must stand out on this sheet. <br />8. The location of the outlets from the infiltration basin must be aligned with the existing <br />drainage and utility easement on the property to the east. <br />C4.1: <br />1. A sheet specific legend is required listing all symbols and lines on this sheet. <br />2. Add note "6" DIP and smaller is Class 53." <br />3. Change City of Ramsey Public Works to City of Ramsey Engineering. The phone number <br />is 763 433-9894. <br />4. Label valves and manholes in plan view. <br />