Laserfiche WebLink
Review File: Ramsey Elementary School <br />Site Plan Application <br />Engineering Review <br />December 21, 2017 <br />Page 2 of 6 <br />The full property boundary must be shown on one of the plan sheets. It must be dark like the <br />building outline or site features. <br />The access easement along the south edge of the property must be vacated. <br />Drainage and utility easements are required around the perimeter of the site. <br />The note about the drainage and utility easement for extending sanitary sewer must only appear <br />on sheet C1.51. <br />C1.11 <br />This is the removals sheet. Information on the removal of the existing house must be shown on <br />this sheet. <br />The existing septic system must be removed and the well sealed. <br />The note about the drainage and utility easement for extending sanitary sewer must only appear <br />on sheet C1.51. <br />All items removed must not appear on other sheets. <br />Sheet C 1.40 is not in this sheet. Update the reference. <br />C1.21 <br />Show the connection between the repurposed building and the driveways. <br />All items removed must not appear on sheets other than the removal sheet. <br />The note about the drainage and utility easement for extending sanitary sewer must only appear <br />on sheet C1.51. <br />C1.31 <br />Move detail reference 9A/C2.12 off the flared end symbol. <br />Pedestrian Ramps must be added at the following locations: <br />• End of the sidewalk on the south side of the bus drive. <br />• The west end of the island across from the ramp above. <br />• End of the sidewalk on the south side of the main drive. <br />• North side of the main drive across from the ramp above. <br />• At the ends of the walks at Nowthen Boulevard. <br />• On the South side of the main drive opposite the main entrance walk and opposite the east <br />fire lane. <br />Additional pedestrian ramps may be required at the intersection of the main drive and Nowthen <br />Boulevard when the configuration of this intersection is finalized. <br />The note about the drainage and utility easement for extending sanitary sewer must only appear <br />on sheet C1.51. This easement must be recorded prior to approving final site plans for the project. <br />C1.41 <br />Adjust Grading north of bus drive to direct runoff to Nowthen Blvd, not the adjacent property. <br />