My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/04/2018
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2018
>
Agenda - Planning Commission - 01/04/2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:29:58 AM
Creation date
1/25/2018 9:11:03 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/04/2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
231
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Review File: Ramsey Elementary School <br />Site Plan Application <br />Engineering Review <br />December 21, 2017 <br />Page 3 of 6 <br />Show the EOF location on the plan. <br />Add the first floor elevation (FFE) to the plan. <br />Wetlands 2& 3 do not have overland drainage routes. See discussion in stormwater plan review <br />section below. Revise grading/ stormwater plan. <br />Change name of local water authority to Lower Rum River Watershed Management Organization. <br />Revise note on street cleaning: <br />The contractor shall have a pickup type sweeper on site or available within 3 hours when notified <br />by the City that sweeping is required. The City reserves the right to do the work and bill the <br />developer's escrow if the work is not done in a timely manner. <br />Water for dust control may not be obtained from hydrants. The City has a water fill station at <br />Quicksilver St., south of 167th Avenue for water. <br />C1.51 <br />Turn off the contour and elevation information on this sheet. The pond outlines must be left on. <br />Maximum hydrant spacing is 300 feet. This distance is measured around, not through, the building. <br />The note about the drainage and utility easement for extending sanitary sewer must only appear <br />on sheet C1.51. This easement must be recorded prior to approving final site plans for the project. <br />Flared End Sections must extend to 2 feet above bottom of pond. The fine sands in Ramsey erode <br />easily. The soils around the pond are primarily sand and will not retain water. <br />The detail reference for the Outlet Control Structure must be shown. <br />The Emergency Overflow may not be used to pass a portion of the 100 year storm. The pipes must <br />be revised to pass all of the 100 year storm. <br />The culverts under the main driveway, bus access and single family residence must be sized to <br />pass the 100 year storm. The culvert sizes must be specified on the plans. <br />The ditch size must be verified by survey from the pond outlet to Trott Brook to ensure flooding <br />or erosion will not occur. <br />The proposed 100 year elevation of the wetlands must be revised, the wetlands do not have an <br />outlet at the elevation listed on the plans. <br />Verify the sizes of CBI, CB2 & CB3. Our review indicates a 60 inch structure may work instead <br />of the 72 inch. <br />Screen the area behind the notes so lines are not visible. <br />
The URL can be used to link to this page
Your browser does not support the video tag.