My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 02/01/2018
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2018
>
Agenda - Planning Commission - 02/01/2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:30:11 AM
Creation date
2/5/2018 12:08:51 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
02/01/2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Review File: Rum River Meadows <br />Preliminary Plat Plan Review <br />Engineering Review <br />January 25, 2017 <br />Page 2 of 3 <br />Cl, C2, C3 <br />Revise legend (all sheets), Add riprap symbol, remove symbols not used on sheet. <br />Show the proposed street and ditch profile for all culvert sections. <br />Drainage and utility easements must be shown from ROW to Pond. Turn off set back lines except <br />on Grading plans. <br />Gl, G2, G3 <br />Add Note to Final Grading Plan: The ponds and infiltration basins were graded to final grades. <br />Pad elevations may not be to proposed grades. Each house survey must conform to the approved <br />grading plan. Proposed deviations are subject to City Review and approval and will not be <br />approved if the drainage patterns are substantially altered. <br />Drainage and utility easements over swales must be wide enough to contain the proposed flows. <br />This swale is not centered on the lot line. Submit cross section of all swales with 100 year flow <br />elevations. <br />The lowest floor elevation of all development, including basements, must be at least 3 feet above <br />the highest anticipated ground water table, 2 feet above the designated or designed 100-year flood <br />elevation, or 1 foot above the emergency overflow, whichever is higher. <br />Show all drainage and utility easements. <br />Submit geotechnical report upon receipt of this report. The geotechnical data must be reviewed <br />before the Preliminary Plat is forwarded to the City Council for approval. <br />Submit Preliminary design report with boring logs for the individual septic systems. <br />Revise sweeping note to read: "Contractor shall have a pickup type sweeper on site or available <br />within 3 hours after notification by City that sweeping is required. <br />Show culvert length and invert elevations on grading plans. <br />SW1, SW2 <br />Add note: "Email inspection reports for post rainfall and weekly inspection to City. Provide full <br />set prior to project closeout." <br />Add Note: "The City shall approve the Notice of Termination (NOT) prior to submittal to the <br />MPCA. <br />Use the same Title block for all sheets. <br />STORMWATER REPORT <br />Existing conditions <br />Revise the drainage map and model to reflect that the site is split by Armstrong Boulevard and by <br />Tiger Street on the south side of Armstrong Boulevard. There are also several low areas on the <br />site that appear to trap water. The number of existing subcatchments must match the number of <br />
The URL can be used to link to this page
Your browser does not support the video tag.