Laserfiche WebLink
2017FYA-BASE.DY'0 <br />NOTES: <br />1) ALL ITEMS OF THIS SIGNAL SYSTEM ARE INPLACE AND SHALL BE <br />REUSED AND MAINTAINED INPLACE, UNLESS OTHERWISE NOTED <br />ON PLANS. <br />2) ALL HANDHOLES ARE PVC HANDHOLES WITH METAL FRAMES AND <br />COVERS AND ARE INPLACE (REUSE AND MAINTAIN INPLACE). <br />3) CONTRACTOR SHALL REMOVE ALL INPLACE "HAND/WALKING PERSON" <br />LENSES FROM EXISTING ONE —SECTION McCAIN PEDESTRIAN SIGNAL <br />HOUSINGS, AND SHALL FURNISH AND INSTALL NEW COUNTDOWN <br />TIMER LED "HAND/WALKING PERSON" LENSES IN THEIR PLACE <br />(REUSE HOUSINGS AND VISORS AS DENOTED IN THE PLANS). SEE <br />SPECIAL PROVISIONS. <br />4) ALL LOOP DETECTORS ARE INPLACE AND SHALL BE REUSED AND <br />MAINTAINED INPLACE AND OPERATIONAL, EXCEPT AS FOLLOWS: <br />CONTRACTOR SHALL FURNISH AND INSTALL NEW LOOP DETECTORS <br />D1-2, D3-1, D3-2, D5-2, D7-1, AND D7-2 IN PVC PER DETAILS <br />INCLUDED ELSEWHERE IN THESE PLANS. LOOP DETECTOR WIRES <br />FOR NEW LOOP DETECTORS SHALL BE CROSS —LINKED POLY— <br />ETHYLENE (XLP) #12 AWG IN 3/4" NMC. SEE SPECIAL PROVISIONS. <br />5) ANY DAMAGE TO INPLACE TRAFFIC SIGNAL FACILITIES (CONDUIT, <br />CABLES, HANDHOLES, SIGNAL POLES, ETC.), DUE TO TRAFFIC <br />SIGNAL REVISION WORK, SHALL BE REPAIRED BY CONTRACTOR TO <br />SATISFACTION OF THE ENGINEER, AT NO EXPENSE TO THE COUNTY. <br />6) CONTRACTOR SHALL MAINTAIN OPERATION OF THE SIGNAL SYSTEM <br />AT ALL TIMES, EXCEPT AS OTHERWISE APPROVED BY ENGINEER. <br />7) ALL NEW VEHICULAR SIGNAL HEADS SHALL HAVE BACKGROUND <br />SHIELDS FURNISHED & INSTALLED BY CONTRACTOR. ALL INPLACE <br />VEHICULAR SIGNAL HEADS BEING REUSED AS PART OF REVISE <br />SIGNAL SYSTEM "B" HAVE BACKGROUND SHIELDS (REUSE AND <br />MAINTAIN INPLACE). <br />8) LOCATION OF NEW LOOP DETECTORS SHALL BE DETERMINED IN <br />THE FIELD BY THE ENGINEER. <br />F & I = NEW, FURNISH AND INSTALL. <br />S & I = INPLACE, SALVAGE AND INSTALL. <br />10) SEE SPECIAL PROVISIONS FOR COUNTY FURNISHED MATERIALS <br />TO BE INSTALLED AND MADE OPERATIONAL BY CONTRACTOR. <br />11) ALL NEW VEHICULAR SIGNAL HOUSINGS, BACKGROUND SHIELDS <br />AND VISORS SHALL BE FABRICATED USING BLACK POLYCARBONATE <br />MATERIALS. SEE SPECIAL PROVISIONS. <br />12) SEE SPECIAL PROVISIONS REGARDING NEW TYPE C SIGN PANELS <br />TO BE FURNISHED AND INSTALLED BY CONTRACTOR (INCLUDED <br />AS PART OF PAY ITEM FOR "REVISE SIGNAL SYSTEM B"). <br />9) <br />DRAWN BY: <br />DESIGNER: <br />CHECKED BY: <br />DESIGN TEAM <br />JMG <br />JMG <br />JMG <br />NO. BY DATE <br />OINPLACE — PEDESTAL FOUNDATION <br />(MAINTAIN 13' PEDESTAL POLE, BASE, WIND <br />INPLACE) 1—ONE WAY SIGNAL —POLE MOUN' <br />1—SET CD PED SIGNALS —POLE MI <br />1—PEDESTRIAN PUSH BUTTON <br />2—R6-1 SIGN PANELS —POLE MOl <br />EXTENDED INTO H.H.2: <br />3" R.S.C. <br />1-12/c#12 <br />1-5/c#12 <br />— 1-3/c#12 <br />INPLACE <br />(REMOVE) <br />F & I <br />INPLACE <br />(REMOVE) <br />— ONE WAY SIGNAL AND MOUNT —POLE MOUN' <br />1—"HAND/WALKING PERSON" LENS <br />1—PED PB INSTRUCTION SIGN (R10-4b) <br />— 1—R9-3 SIGN —FACING POLE 6 <br />1—ONE WAY SIGNAL AND STRAIGHT MOUNT — <br />POLE MOUNTED (NEW 7-2) <br />1—SET LED CD "HAND/WALKING PERSON" LE <br />1—PED PB INSTRUCTION SIGN (R10-3e) <br />1—R9-3 (NO PED XING) SIGN —FACING POLE <br />INPLACE — PA100 POLE FOUNDATION <br />(MAINTAIN TYPE PA100—A—D40-9 MAST ARM P <br />INPLACE) LUMINAIRE-250 W HPS <br />1—ONE WAY SIGNAL —POLE MOUNTED <br />2—SETS CD PED SIGNALS —POLE MOUI <br />2—PEDESTRIAN PUSH BUTTONS <br />ONE WAY EVP DETECTOR —POLE MOUI <br />EXTENDED INTO H.H.6: <br />3" R.S.C. <br />2-12/c#12 <br />3-3/c#12 <br />2-3/c#20 <br />— 1-3/c#12 (LUM) <br />40—FOOT MAST ARM <br />ONE WAY SIGNAL AND MOUNT —POLE MOUNTED <br />2—"HAND/WALKING PERSON" LENSES <br />2—PED PB INSTRUCTION SIGNS (R10-4b) <br />R10-12 SIGN PANEL —OVERHEAD <br />INPLACE ONE WAY SIGNAL —OVERHEAD AT 11' (4-2) <br />(S & I) I ONE WAY EVP DETECTOR AND UGHT—OVERHEAT <br />TYPE D SIGN PANEL —OVERHEAD AT 15' (D-3) <br />F & I -- 45—FOOT MAST ARM (WITH MID —MAST ARM MOUN <br />1—ONE WAY SIGNAL AND ANGLE MOUNT—OVERHE/ <br />1—STRAIGHT MOUNT —OVERHEAD AT 11' (FOR 4-2 <br />1—ONE WAY SIGNAL AND ANGLE MOUNT —POLE MC <br />(NEW 1-2) <br />2—SETS LED CD "HAND/WALKING PERSON" LENSE <br />2—PED PB INSTRUCTION SIGNS (R10-3e) <br />R10—X12 SIGN PANEL —ADJACENT TO 7-1 <br />1-6/c#14 <br />OINPLACE -- PA90 POLE FOUNDATION <br />(MAINTAIN TYPE PA90—A-35—D40-9 (DAVIT AT <br />INPLACE) LUMINAIRE-250 W HPS <br />2—ONE WAY SIGNALS —OVERHEAD AT C <br />LUMINAIRE-250 W HPS <br />ONE WAY EVP DETECTOR AND LIGHT F <br />TYPE D SIGN PANEL —OVERHEAD AT 2( <br />EXTENDED INTO H.H.9: <br />3" R.S.C. <br />2-12/c#12 <br />1-3/c#12 <br />1-3/c#20 <br />— 1-3/c#12 (LUM) <br />INPLACE — ONE WAY SIGNAL AND MOUNT —POLE MOUNTED <br />(REMOVE) <br />F & I -- 1—ONE WAY SIGNAL AND ANGLE MOUNT —POLE MOI <br />(NEW 1-1) (MOUNT SIGNAL HEAD SO THAT MOU <br />YELLOW AND FYLA INDICATIONS, SO THAT POST <br />RIGHT" SIGN DOES NOT BLOCK SIGNAL INDICATIC <br />R10—X12 SIGN PANEL — INSTALL EITHER ABOVE S <br />-- OR ON MAST ARM CLOSE TO POLE <br />I HEREBY CERTIFY THAT THIi <br />UNDER MY DIRECT SUPERNS <br />PROFESSIONAL ENENNGIINEER�r�UNI <br />REVISIONS Date- March 720 <br />