My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 09/01/2005
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2005
>
Agenda - Planning Commission - 09/01/2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:37:55 AM
Creation date
8/26/2005 1:01:09 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
09/01/2005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lin bita Iflc <br />Side Yard S~tback for COriler <br /> <br />Major/Minor Arterial Setback <br /> <br />the road right ofwa~ <br />Service Road Setback <br /> <br />.'Vlaximum I~uilding lleight <br />(n~easnred from mean grOllUd <br />level tn mcan aS!mud gable) <br />Minimum tqonr Areas: (Main Floor <br /> <br />Rambler with g:Lratle <br />Split level with garage <br /> <br />Fwo~story with <br />'r,nvnho.se with ~aragc <br /> <br />,_ .l_)![plex Dwelline, <br /> <br />l'winhomc I)wclling <br /> <br />Multi-fa[uilT~ D~vclling~__ <br /> <br />¥1aximum Ihfildint~ Lot Coverage <br />.%'iaximu[u driveway width at <br /> <br />Maximnm aural)er of <br />driveways~* <br /> <br />Side yard setback for <br />d r i v c w ay~sf'~* <br />Required driveway surface** <br /> <br />30 feet 30 feet 40 feet 40 feet <br />30 tiger 30 feet 40 feet 40 fi~ct <br /> <br />60 feet from right-et:way <br />centerline plus thc local <br />applicable setback <br />35 feet <br /> <br />35 ti:ct <br /> <br />912 square feet (main floor). <br />720 square feet (total of main <br />..living areas) <br /> <br />720 square feet (main floor). <br />PUD Required <br />I bedroom - 700 square feet <br />2 bedrooms - 800 square feet <br />3 bedrooms - 960 square feet <br />each additional bedroom 125 <br />square feet <br /> <br />60 feet from right-otXway <br />centerliue plus thc focal <br />applicable setback <br />35 feet <br /> <br />35 feet <br /> <br />912 square feet. (ma. in floor) <br />720 square feet (total of main <br />living areas) <br /> <br />720 5quarq feet (main floor) <br />N/A <br /> <br />NA <br /> <br />60 feet from right-of-way <br />centerline plus the local <br />ap. plicable setback <br />35 feet <br /> <br />35 feet <br /> <br />912 square feet (main floor) <br />720 square feet (total of main <br />living areas) <br />72.0 square tiget (main floor) <br />NA <br /> <br />60 feet from right-of-way <br />centerline plus the local <br />applicable setback <br /> <br />35 feet <br /> <br />35 feet <br /> <br />912 squar, e feet (main floor) <br />720 square feet (total of main <br />living areas) <br /> <br />NA <br /> <br />NA NA NA <br />NA NA NA NA <br />NA NA NA NA <br />35% 35% 35% 35% <br /> <br />30 t~ct; 24 feet on cul-de- <br />sacs <br /> <br />per street frontage <br /> <br />5 feet <br /> <br />30 feet; 24 feet on cul-de- <br />sacs <br /> <br />5 feet <br /> <br />Bituminous, Concrete or <br />Class V <br /> <br />30 feet; 24 feet on cul-de- <br />sacs <br /> <br />I per street frontage for <br />clustered lots/ <br />2 for non-clustered lots <br /> <br />5 feet <br /> <br />Bituminous, Concrete, or <br />Class V <br /> <br />Bituminous or Concrete <br /> <br />30 feet; 24 feet on cul-de- <br />sacs <br /> <br />2 <br /> <br />5 feet <br /> <br />Bituminous, Concrete or <br />Class V <br /> <br />Accessory Strltctt[re Setb,'lCkS: <br />I:rrmt~ 30 t~el or same as principal 30 feet or same as principal <br /> structure, which ever is structure, whichever is <br /> greater greater <br />Rear 5 t~et 5 feet <br />Side 6 t~et 6 feet <br /> <br />Side (:el'lief 30 feet 30 t~et <br /> <br />40 feet or same as principal <br />structure, whichever is <br />greater <br />5 feet <br />10 feet <br />40 feet <br /> <br />40 feet or same as principal <br />structure, whichever is <br />greater <br />5 feet <br />10 feet <br />40 feet <br /> <br />* Refer to Section 9.11.02, Subd. 7, for additional front yard setback provisions for lots 2 acres and greater in size. <br />**A zoning permit is required to install any driveway that is not associated with work requiring a building permit. <br /> <br />For lots located within the 2020 MUSA where adjacent structures existing as of July 1, 2002, <br />have a different setback from that required herein, the front yard setback shall conform to the <br />prevailing setback of adjacent structures. If adjacent structures have different setbacks from one <br />another, the minimum front yard shall be the average of the two (2) adjacent structures. <br /> <br />SECTION 2. SUMMARY <br /> <br />The k)llowing official summary of Ordinance #05-~ has been approved by the City Council of <br />the City of Ramsey as clearly informing the public of the intent and effect of the Ordinance. <br /> <br />[t is the intent and effect of Ordinance #05-__ to amend Ramsey City Code Chapter 9 (Zoning <br />:_md Subdivision of'Land) to: <br /> · Establish regulations and guidelines for outdoor solid fuel fired heating devices. <br /> · Renumber 9.11.14 (Compliance) to 9.11.15. <br /> <br />57 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.