Laserfiche WebLink
Dyna-P[axt building expansion <br />October 28, 200J <br /> <br />additional trees. The site currently has fi2y-eight (Sg) trees and th~rty-five (35) shrubs that were <br />h~smlled both as part of the original site development and as supplemental plantings-over the <br />years. The existing number of trees far exceeds the current standards for new const~ction while <br />~he number of existing shrubs is somewhat low. <br /> <br />The landscaping plan, dated September 30, 2005, includes twenty (20) new shrubs. Due to the <br />size ,,~t: the addition and the fact that the pervious area of the site would not be reduced, Staff <br />believes that the proposed landscaping is adequate. Both species are acceptable. The minimum <br />required size for the shrubs is twenty-four (24) inches in height. <br /> <br />Tree Preservation: Other than the plantings that were installed as part of the original <br />ctmstruction, there are no other areas of significant trees. Therefore, no tree preservation plan is <br />necessa~?'. <br /> <br />Ground Cover: All landscaped areas must be sodded and irrigated per City Code. <br /> <br />Architectural Standards: The one-story building does not exceed the 65-foot height limit:. The <br />exterior wails are proposed to match the existing building, which consist of a combination of <br />ct)mmon, single score, burnished and rock face block, which is in accordance with City Code. <br /> <br />Waste Storage: City Code requires that all solid waste and refuse receptacles be stored within a <br />completely screened structure or container. The dumpstdr area will be housed within the <br />builcling. <br /> <br />Access: The property currently gains access from Unity Street, no new accesses are proposed. <br /> <br />Off-Street Parking - Spaces Required: City Code requires 1 parking space for each 300 square <br />~'eet ~' o~'fice floor area and 1 parking space for each 1,000 square feet of <br />manu~hcturing/warehouse area. The proposed building addition will require an additional 8 <br />parking stalls for the proposed manufacturing area. The site plan proposes adding 13 parking <br />:;t:~.l/s to Ire existing 68 parking stalls, which complies vdth City Code. <br /> <br />Off Street Parking - Design: In accordance with City Code, all parking and maneuvering areas <br />must be surf:aced with bituminous and the perimeter of all pavement must be finished with B6/12 <br />concrete curbing. <br /> <br />Drainage and Grading: Current drainage and gading is sufficient for the site. The addition <br />,,vill bc taking place on an existing impervious surface parking lot. The curve numbers will not <br />,,:[range with the building addition. Currently, the stormwater drains to an existing pond on the <br />east end ol" the site. The building addition wi.il not have an adverse affect on the pond. <br /> <br />REU Number: This site will incur a quarterly storm water charge, which is based upon the <br />am~.)unt ol: impervious area. The residential equivalent unit number (REU) will remain the same <br />:~ince thc development is occurring on an existing impervious area. <br /> <br /> <br />