Laserfiche WebLink
TABLE A <br /> EDGE OF PAVEMENT TRUNCATED DOME 6"THICK CONCRETE WALK TO <br /> P� PANELS EDGE OF PAVEMENT A <br /> \`OQ FROM DGEPLACE EOF3CONCRETE FROM EDGE EOF CONCRETE <br /> MODRED CLASS 5 ��.�Ga��o CATCH BASIN AT P.C. ILI z /P <br /> 0 1' <br /> w \11 .I. y MATCH EXISTING DRIVEWAY RIGHT OF WAY <br /> 0000000 0000000 0000000 0000000 0000000 <br /> �o h 888 88 0001 8888M � �� 818 — — — — — <br /> /� /� /� T /� ^ �\ y, �, �, �, �, �, 0000000 0000000 0000000 0000000 0000000 <br /> n I— / I I— I / A 1 / \ N \ 0000000 0000000 0000000 0000000 0000000 <br /> 0000000 0000000 0000000 0000000 0000000 <br /> W W W � � W W W SLOPE AS REQUIRED 8 VARIABLE <br /> 10' v 41 'k v 1P v y . . . . . . . . . . <br /> EXISTING CONCRETE <br /> B618 CURB 3 <br /> TRANSITION SURMOUNTABLE W W 1P � W W 11, CURB & GUTTER <br /> PASISING & GUTTER CURB & GUTTER `� y � 4, 4, <br /> 4, y 4, y <br /> :""T BIT.. FULL DEPTH <br /> i <br /> y y 10' BIT. TRAIL <br /> 2-4' PIECES OF #4 REBAR AT -3,0'� MAXIMUM DRIVEWAY WIDTH 20,0' —3,0'� <br /> 99 <br /> 100 ALL P.C.'S AND COLD JOINTS. �A <br /> � <br /> 3 /4 9 9 ^J,1O 100 <br /> 10 SECTION A—A <br /> <` 3" r � 3" <br /> 6' CONCRETE VARIABLE SEE CITY PLATE STR-1 <br /> FOR CURB AND GUTTER <br /> 9 9 5 0 0 v. d t' CONCRETE PAVEMENT <br /> INLINE CATCH BASIN <br /> 88 8888888 8888888 8888888 8888888 8888888 O 00 O 88888808 4' CLASS 5 MODIFIE➢ BASE <br /> 35 O 0000000 0000000 0000000 0000000 0000000 Z' 4' SEE CITY PLATE STR-26No . 4 0000000 0000000 0000000 0000000 0000000 CONCRETE DRIVEWAY ENTRANCE <br /> 8008888 88888 8888888 8888888 8888888 <br /> SURMOUNTABLE 10 ° Ada ° °° 1' <br /> Nngo o CURB & GUTTE TRANSITION SURMOUNTABLE a <br /> liCURB & GUTTER <br /> MINIMUM THICK <br /> SEE CITY PLATE STR-1 <br /> (MATCH EXISTING) FOR CURB AND GUTTER <br /> TRUNCATED DOMES 6" THICK CONCRETE WALK 77" -- — <br /> NO ` 40 1 0 3 5 2�X2' PANEL `i _ BITUMINOUS PAVEMENT�BASE <br /> 2-4' PIECES OF #4 REBAR AT 4'SEES CITY PLATEESTR-26�-- <br /> N o . 200 5 10 ALL P.C.'S AND COLD JOINTS. NOTE: BITUMINOUS DRIVEWAY ENTRANCE <br /> 1 . SAWCUT BIT. FULL DEPTH / REMOVE BIT. <br /> NOTES: 10' 2" 2. PLACE 6" THICK CONCRETE FOR TRUNCATED DOMES UP TO EDGE OF PAVEMENT. NOTES: <br /> 1 . THE AGGREGATE BASE CONSTRUCTION WILL BE ACCEPTED FOR PAYMENT 3. MEDIUM BROOM FINISH ON CONCRETE 1. PANEL WIDTH SHALL NOT EXCEED 10 FT. WITHOUT A CENTERLINE CONSTRUCTION JOINT. <br /> 4. MAINTAIN 3" FROM EDGE OF TRUNCATED DOMES AND CONCRETE EDGE. 2. CONCRETE DRIVEWAY TO BE ONE COURSE CONCRETE PAVEMENT. (SEE SPECIAL PROVISIONS <br /> IN ACCORDANCE WITH THE PROVISIONS IN TABLE A. 5. IT MAY BE NECESSARY TO TRIM TRUNCATED DOME PANELS. FOR CLASS OF CONCRETE.) <br /> 2. IF THE AGGREGATE BASE FAILS TO MEET THE REQUIREMENTS OF TABLE 6" /DOT B618 CONC. C & G 3. CONCRETE DRIVEWAYS TO BE 6" THICK. <br /> A THE MATERIAL CAN BE CORRECTED IN PLACE OR REMOVED AND 7 SURMOUNTABLE C & G 4. Y2" EXPANSION JOINT, Y2" PREFORMED JOINT FILLER MATERIAL, AASHTO M 213 (REQUIRED <br /> REPLACED WITH MATERIAL THAT MEET THE REQUIREMENTS OF TABLE A. WHEN 2 CONCRETE AREAS ARE POURED SEPERATELY.) <br /> 3. IN THE EVENT THAT RECYCLED MATERIAL IS USE IT MUST MEET MNDOT 5. BITUMINOUS DRIVEWAYS MINIMUM 2" THICK, MATCH EXISTING BITUMINOUS PAVEMENT <br /> REQUIREMENTS FOR RECYCLED BASE. 10' TRANSITION NOTE: NOT TO SCALE THICKNESS. <br /> AILS: <br /> STANDARD L STANDARD DETAILS: <br /> APPR❑VED MODIFIED CLASS 5 APPROVED: CATCHBASIN PLACEMENT — APPROVED: RUNCATED DOME PLACEMENT APPROVED: RESIDENTIAL DRIVEWAY - <br /> 2 - 2003 SPECIFICATI❑NS 4 — 2016Ci t of SURMOUNTABLE CURB 7 — 2015 BITUMINOUS TRAIL NO CURB 1 - 2016City NO SIDEWALK Of <br /> � �CITY PLATE No, CITY PLATE No. � � CITY PLATE No. CITY PLATE No, <br /> STR-26 STR-27R STR-28 � � STR-30 <br /> w LJ <br /> V) J <br /> z m z C)w w w (n <br /> LU > O <br /> Q � Q <br /> Q DOz z <br /> z z z <br /> N N V) o W <br /> Z I—I <br /> w w w <br /> C7 w w I W <br /> Zry <br /> I I <br /> � � W <br /> ~ > > <br /> Wm � w a I <br /> 0 <br /> LU <br /> w <br /> w w J <br /> zQ <br /> Z x I <br /> " w w Q u L1J <br /> m � 0 D V) Z I Q <br /> J_ > J I W <br /> D H V) <br /> W "wa z i > <br /> w <br /> (Hid3411f13) j z g • =) Z <br /> .................................... w w _ <br /> &N3N3AVd 118 immvS g g r Q ? O ^ O <br /> w x a O z w <br /> > , , v <br /> a tz Q <br /> COm /E N W C') <br /> w <br /> LU <br /> CO /� I <br /> Unl0 wwQ Q �/ <br /> Vi 2C� a a Q I <br /> H <br /> CO /I <br /> 0 1--- i `4 >— <br /> N W a w <br /> d WLU <br /> V) Ln I ~ 0 <br /> O > U z <br /> m Q z <br /> a a w <br /> w <br /> /I <br /> QLAJ <br /> I <br /> a <br /> CO <br /> w U <br /> O 0 Q <br /> w m OU CO Q Q <br /> m Q Y �: (D 0: <br /> Q d m <br /> D H V (D Z) <br /> (D N <br /> w Q 0 <br /> w m un w <br /> DC V) > <br /> Z F-- V) 0 <br /> U O x QCc <br /> x_ 2 u a <br /> V) D cfl w 0 Q <br /> O U CV LU V) z <br /> LJ Z Q I CC 0 w O <br /> m �_ o LF- o 0mp 0 <br /> = Ca U aJLdN( i QW�/ <br /> CD Z <br /> � o W�> a _ <br /> �o �ClJ+ <br /> 02 Lncnc� �0� ,,, z <br /> �V)<Cn UL�L a z (`0 <br /> (n p 0 Q �U LJ 0 Ld cn <br /> Ld wa <br /> COQ U�� (w�N a O <br /> V1 <br /> w <br /> in 0- <br /> 1)1 26V NELRengineering <br /> 00-ENG-123074-SHEET-DYES-CITY <br /> CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS <br /> Revisions <br /> 7am <br /> hereby certify that this plan was prepared by /1,� Date NN 7� HARMONY FARMS <br /> (65)_)68)_-1914 Name Puou'L / I 1. 2024-02-05 City Comments LElV1VAi� <br /> 2422 Enterprise Drive e or under my direct supervision and that I PRELIMINARY DETAILS 8.12 30 <br /> Mendota Heights,MN 55120 Fax: 681-9488 a duly Licensed Professional Engineer Brian N.Molinaro Designed 16305 36TH AVE.NO., SUITE 600 OFwww.pioneereng.comder the laws of the State of Minnesota Reg.No. 47504 Date Drawn PLYMOUTH,MINNESOTA 55446 RAMSEY,MINNESOTA <br /> ©2023 Pioneer Engineering,P.A. <br />