Laserfiche WebLink
BITUMINOUS TRAIL DESIGN <br /> — PATHWAY WIDTH 10 ft <br /> B - SHOULDER WIDTH 1 ft MIN. <br /> 3' TO 6' <br /> a <br /> � 2.0 <br /> 3" SP 9.5 WEARING COURSE MIXTURE (2,13) <br /> 6" CL 5 AGGREGATE BASE (MODIFIED) <br /> 12" SELECT GRANULAR BORROW <br /> 6" MINIMUM SCARIFY AND RE COMPACT <br /> (SUBGRADE PREP) <br /> FABRIC IF DIRECTED BY ENGINEER <br /> NOTES: <br /> 1. TRAIL CONSTRUCTION SHALL HE IN ACCORDANCE WITH THE <br /> MOST RECENT EDITION OF THE CITY OF MONTICELLO GENERAL <br /> SPECIFICATIONS AND STANDARD DETAIL PLATES. <br /> 2, PEDESTRIAN RAMPS SHALL BE CONSTRUCTED WITH TRUNCATED <br /> DOMES AND CONFORM TO ADA REQUIREMENTS. <br /> 3. MODIFY SURFACING, BASE, AND SUBGRADE DESIGN BASED ON <br /> EXPECTED VEHICULAR USE AND SUBGRADE SOILS. <br /> Title: <br /> Standard Plate Library Trail section <br /> City of Monticello Date. Plate �. <br /> 03- 5 No. <br /> Reis: 5013 <br /> 3-1 5 <br /> CAUSERS\DEBRA MUSGROVE\DOWNLOADS\PATHWAY MIRCO-SURFACING-2020 MPL.DOCX Page 17 <br />