My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Description: Warehouse Remodel Bldg. 1 Date: Tuesday, January 6, 2026 <br /> <br />2 | Page <br /> <br />6. Maximum exit access travel distance: 75 feet. <br />7. Number of exits required: 1 minimum each bay <br />8. Exit signs: None required <br />9. Emergency lighting: None required <br />10. A fire alarm system: None required <br />11. Smoke / CO alarms: None required <br />12. Fire extinguishers: provide one at each exit door. <br />13. Door swing: Out <br />14. Panic hardware: None required. <br />15. Minimum number of plumbing fixtures: 1 unisex. <br /> <br />This code study is based on the 2018 International Building Code by ICC using Plan Analyst. <br />www.plananalyst.com <br /> <br />ADDRESS IDENTIFICATION: <br />Buildings shall be provided with approved address identification. The address identification shall <br />be legible and placed in a position that is visible from the street or road fronting the property. <br />Characters shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. <br />Each character shall be not less than 4 inches high and not less than 0.5 inch wide. They shall be <br />installed on a contrasting background. When required by the fire official, address numbers shall <br />be provided in additional approved locations. When access is by a private road and the building <br />address cannot be view from the public way, a monument, pole or other approved sign shall be <br />used to identify the structure. (502.1) <br /> <br />SITE DESCRIPTION: (506.3.2 and 202 FIRE SEPARATION DISTANCE) <br />The north side has a public way. Distance to public way = 52.0 ,width = 60.0 <br />Length of perimeter facing the public way = 95.0 This side can be accessed from a street or <br />approved fire lane. <br />The east side has an imaginary line between two buildings.(705.3) Distance to building = 20.0 <br />,the imaginary line = 10.0 <br />Length of perimeter facing other building = 152.0 This side can be accessed from a street or <br />approved fire lane. <br />The south side has a lot line. Distance to lot line = 42.0 <br />Length of perimeter facing lot line = 95.0 This side can be accessed from a street or approved <br />fire lane. <br />The west side has a public way. Distance to public way = 100.0 ,width = 60.0 <br />Length of perimeter facing the public way = 152.0 This side is not accessible from a street or <br />approved fire lane. <br />Perimeter of the entire building = 494.0 feet. <br />Perimeter which fronts a public way or accessible open space = 342.0 feet. <br />Weighted average of the width of public way or accessible open space = 16.7 feet. (506.3.2) <br />Allowable area increased 24.57% due to frontage. (506.3) <br /> <br />HEIGHT OF BUILDING: <br />Actual height of building = 20.00 ft Allowed building height = 65.00 ft The height is within the <br />allowed height. (504.1 and Table 504.3)
The URL can be used to link to this page
Your browser does not support the video tag.