Laserfiche WebLink
Project Description: Warehouse Remodel Bldg. 1 Date: Tuesday, January 6, 2026 <br /> <br />3 | Page <br /> <br /> <br />BUILDING INTERIOR: <br />ALLOWABLE AREA AND HEIGHT: <br />FL NAME OCC MAX FLR AREA ALLOWED RATIO STATUS <br />--------------------------------------------------------------------- <br />F1 Warehouse S1 2 14440 21800.21 0.66 OK <br />TOTAL FOR FLOOR 14440 21800.21 0.66 OK <br />BUILDING TOTAL 14440 21800.21 0.66 OK <br /> <br />Notes: <br />Allowable area is based on Table 506.2 and Section 506. <br />Allowable number of stories is based on Table 504.4 and Section 504 <br />Allowed area increased 24.6% for frontage increase. (506.3) <br />NOTE: Storage areas were set to the major use occupancy group because these areas are <br />accessory to the major use of the building. (311.1.1) <br /> <br />EXIT REQUIREMENTS: <br /> NAME NUMB MIN MIN CORRIDOR MAX <br /> OF OF NUMB EXIT PANIC DOOR FIRE TRVL <br />FL AREA OCC EXIT WDTH HDWR SWNG RATING DIST NOTES <br />------------------------------------------------------------------------ <br />F1 Warehouse 29 1 5.8 no any N/A 200 <br /> TOTAL 1st FLOOR 29 2 5.8 no any N/A 200 5 <br /> <br />FOOTNOTES: <br />5. Number of exits from this floor is based on Section 1006.3.2 <br /> <br />NOTES FOR EXIT TABLE: <br />Door swing is based on Section 1010.1.2 <br />Occupant load is based on Section 1004 and Table 1004.5 <br />Exit width is in inches and based on Sections 1005.3.1 and 1005.3.2 <br />For the minimum width of stairways, see Section 1011.2. <br />Exits shall be continuous from the point of entry into the exit to the exit discharge. (1003.6) <br /> <br /> <br />DOOR SWING EXCECPTIONS: <br />Exception 5: Revolving doors complying with Section 1010.1.4.1 <br />Exception 6: Horizontal sliding doors complying with Section 1010.1.4.3 <br />Exception 7: Power-operated doors complying with Section 1010.1.4.2 <br /> <br />EXIT WIDTH NOTES: <br />Exit width is in inches and based on Section 1005.2 <br />Width shown for all areas is based on other egress components. (1005.3.2) <br />Width shown for 1st floor is based on other egress components. (1005.3.2) <br />Width shown for other floors & basements is based on stairways. (1005.3.1) <br />For the minimum width of doors, see Section 1010.1.1. <br />