Laserfiche WebLink
14047 Azurite St NW Buildings 2 and 2 December 22, 2025 <br /> <br />4 | Page <br /> <br />EXIT WIDTH NOTES: <br />Exit width is in inches and based on Section 1005.2 <br />Width shown for all areas is based on other egress components. (1005.3.2) <br />Width shown for 1st floor is based on other egress components. (1005.3.2) <br />Width shown for other floors & basements is based on stairways. (1005.3.1) <br />For the minimum width of doors, see Section 1010.1.1. <br /> <br />EGRESS CONTINUITY: <br />The path of egress travel along a means of egress shall not be interrupted by any building <br />element other than a means of egress component. (1003.6) <br /> <br />EXIT SEPARATION: <br />In areas where 2 exits are required, the minimum separation is 1/2 of the maximum diagonal of <br />the area or floor measured in a straight line between exits or exit access doorways. (1007.1.1) <br />Exception 1: Where interior exit stairways are interconnected by a 1-hour corridor, the separation <br />shall be measured along the shortest direct travel within the corridor. <br />Multiple means of egress shall be sized such that the loss of any one means of egress shall not <br />reduce the available capacity by more than 50 percent. (1005.5) <br /> <br /> <br />MEANS OF EGRESS ILLUMINATION: <br />1. The means of egress serving a room or space shall be illuminated at all times that the space or <br />room is occupied. (1008.2) <br />2. The means of egress illumination shall not be less than 1 foot-candle at the walking surface <br />level. (1008.2.1) <br />3. Illumination shall be provided along the path of travel for the exit discharge for each exit to <br />the public way. (1008.2.3) <br /> See exceptions <br />See section 1008.3 for emergency power requirements. <br /> <br /> <br />ADDITIONAL DOORS: <br />Where additional doors are provided for egress purposes, they shall conform to the requirements <br />in Section 1010. (1010.1) <br /> <br />LANDINGS AT DOORS: <br />1. There shall be a floor or landing on each side of a door. (1010.1.5) <br />2. Such floor or landing shall be at the same elevation on each side of the door. (1010.1.5) <br />3. The floor or landing shall not be more than 1/2 inch lower than the threshold. (1010.1.7) <br />4. Landings shall have a width not less than the width of the stairway or width of the doorway, <br />whichever is the greater. <br /> Where a landing serves an occupant load of 50 or more, doors in any position shall not reduce <br />the landing dimension to less than one half of the required width. The minimum length in the <br />direction of exit travel is 44 inches. (1010.1.6) <br />5. The space between two doors in series shall be 48 inches plus the width of door swinging into <br />the space. (1010.1.8)