My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 01/22/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 01/22/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 2:46:51 PM
Creation date
1/15/2026 2:44:22 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
01/22/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14047 Azurite St NW Buildings 2 and 2 December 22, 2025 <br /> <br />5 | Page <br /> <br /> <br /> <br />BOLT LOCKS: <br />Manually operated flush bolts and surface bolts are not permitted. (1010.1.9.5) <br />Exception 3: Where a pair of doors serves an occupant load of less than 50, manually operated <br />edge- or surface-mounted bolts are permitted on the inactive leaf. The inactive leaf shall contain <br />no doorknobs, panic bars or similar operating hardware. <br />Exception 2: Where a pair of doors serves a storage or equipment room, manually operated edge- <br />or surface-mounted bolts are permitted on the inactive leaf. <br />The unlatching of any door or leaf shall not require more than one operation. (1010.1.9.6) <br />Exception 2: Where manually operated bolt locks are permitted. <br />Exception 3: Doors with automatic flush bolts as permitted. <br /> <br />LOCKS AND LATCHES: <br />Egress doors shall be readily openable from the egress side without the use of a key or any <br />special knowledge or effort. (1010.1.9) <br />Locks and latches shall be permitted to prevent operation where any of the following exists: <br />(1010.1.9.4) <br />2. The main door or doors in Group B, F, M and S areas are permitted to be equipped with key <br />operating locking devices from the egress side provided: <br />2.1 The locking device is readily distinguishable as locked. <br />2.2 A readily visible durable sign is posted on the egress <br />side stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED <br />3. Where egress doors are used in pairs, automatic flush bolts shall be permitted to be used, <br />provided the door leaf having the automatic flush bolts has no doorknob or surface-mounted <br />hardware. <br />5. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism. <br /> <br />BUILDING ACCESSIBILITY: <br />Accessible entrances and accessibility within the building shall comply with Sections 1104 and <br />1105. <br />On floors where drinking fountains are provided, accessible drinking fountains shall be provided. <br />No fewer than 2 drinking fountains shall be provided. One shall comply with the requirements <br />for people in a <br />wheelchair and one for standing persons. (1109.5.1) <br /> <br />MINIMUM NUMBER OF PLUMBING FIXTURES: (2902.1) <br /> <br /> NUMBER WATER CLOSETS LAVATORIES DRINKING <br />FL NAME OF AREA OCC MALE FEMALE MALE FEMALE FOUNTAINS <br />--------------------------------------------------------------------- <br />F1 Building 1 25 1 1 1 1 1 <br />TOTAL for 1st FLOOR 25 1 1 1 1 1 <br /> <br /> <br />[P] 2902.2 Separate facilities. <br />Where plumbing fixtures are required, separate facilities shall be provided for each sex.
The URL can be used to link to this page
Your browser does not support the video tag.